Alcohols and Glycols
Applications | 2015 | Agilent TechnologiesInstrumentation
Monitoring alcohols and glycols in water is essential for environmental assessment, public health, and industrial quality control. Effective detection ensures compliance with regulations and safeguards ecosystems.
This study aims to establish a gas chromatography method for rapid separation and quantitation of six alcohols and glycols in aqueous samples. Target analytes include:
The method employs GC with a wide-bore column and flame ionization detection:
All six compounds achieved baseline resolution within a standard analysis time. The polyethylene glycol stationary phase provided consistent retention times and peak shapes, demonstrating robustness against aqueous matrices.
Integration with mass spectrometric detection could enhance sensitivity and selectivity. Miniaturized GC systems may enable on-site environmental monitoring. Automation and high-throughput platforms could streamline quality control processes.
The presented GC-FID method using the CP-Wax 57 CB column offers an efficient, reproducible, and water-tolerant approach for analyzing alcohols and glycols, suitable for diverse environmental and industrial applications.
No specific references were provided in the source document.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Monitoring alcohols and glycols in water is essential for environmental assessment, public health, and industrial quality control. Effective detection ensures compliance with regulations and safeguards ecosystems.
Objectives and Overview
This study aims to establish a gas chromatography method for rapid separation and quantitation of six alcohols and glycols in aqueous samples. Target analytes include:
- Methanol
- Ethanol
- 1-Propanol
- Ethylene glycol
- Trichloroethanol
- Diethylene glycol
Methodology and Instrumentation
The method employs GC with a wide-bore column and flame ionization detection:
- Column: Agilent CP-Wax 57 CB for Alcohols and Glycols (0.53 mm × 25 m, 1.2 µm)
- Temperature program: 45 °C (0.75 min), ramp to 180 °C at 20 °C/min
- Carrier gas: Helium, 10 mL/min at 50 kPa
- Injector: direct, 220 °C; sample size 0.2 µL, fast injection
- Detector: FID at 230 °C
- Solvent: water
Main Results and Discussion
All six compounds achieved baseline resolution within a standard analysis time. The polyethylene glycol stationary phase provided consistent retention times and peak shapes, demonstrating robustness against aqueous matrices.
Benefits and Practical Applications
- Fast and reliable quantification of common alcohols and glycols in environmental and industrial water samples
- High column inertness minimizes active sites, reducing sample carryover
- Simple direct injection accommodates routine laboratory workflows
Future Trends and Potential Applications
Integration with mass spectrometric detection could enhance sensitivity and selectivity. Miniaturized GC systems may enable on-site environmental monitoring. Automation and high-throughput platforms could streamline quality control processes.
Conclusion
The presented GC-FID method using the CP-Wax 57 CB column offers an efficient, reproducible, and water-tolerant approach for analyzing alcohols and glycols, suitable for diverse environmental and industrial applications.
References
No specific references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Glycols - Purity analysis of propylene glycol to DAB 1996 and USP 23
2011|Agilent Technologies|Applications
Glycols Purity analysis of propylene glycol to DAB 1996 and USP 23 Application Note BioPharma Authors Introduction Agilent Technologies, Inc. The high polarity and selectivity of the Agilent CP-Wax 57 CB column provide the necessary seperation and excellent peak shape…
Key words
glycol, glycoltripropylene, tripropylenedipropylene, dipropylenediethylene, diethyleneglycols, glycolspropylene, propylenecourtesy, courtesysolvent, solventbiopharma, biopharmaethylene, ethylenesample, samplepurity, purityprinted, printedinjector, injectormethanol
Alcohols, C1 – C7
2015|Agilent Technologies|Applications
Alcohols, C1 – C7 Analysis of a standard congener mixture used as reference for distilled spirits Application Note Food Testing & Agriculture Authors Introduction Agilent Technologies, Inc. The Agilent CP-Wax 57 CB phase provides a unique selectivity for the analysis…
Key words
spirits, spiritscongener, congenerdistilled, distilledcourtesy, courtesyagriculture, agriculturewater, waterethanol, ethanolmixtures, mixturesstandard, standardmakes, makesprinted, printedinjector, injectormixture, mixtureusa, usasuitable
Analysis of whisky : Alcohols, C1 – C7
2015|Agilent Technologies|Applications
Alcohols, C1 – C7 Analysis of whisky Application Note Food Testing & Agriculture Authors Introduction Agilent Technologies, Inc. The Agilent CP-Wax 57 CB phase provides a unique selectivity for the analysis of impurities in alcoholic beverages. Besides the separation of…
Key words
whisky, whiskycourtesy, courtesyagriculture, agricultureprinted, printedinjector, injectorusa, usatesting, testingauthors, authorsfood, foodinternal, internalsize, sizetechnique, techniquecarrier, carrierdetector, detectornote
Agilent J&W CP-Wax 52 CB Columns with Improved Inertness Consistency from Column to Column
2016|Agilent Technologies|Technical notes
Agilent J&W CP-Wax 52 CB Columns with Improved Inertness Consistency from Column to Column Technical Overview Introduction Polyethylene glycol (PEG) also known as Wax-type GC columns have been the industry standard for many years for the analysis of a wide…
Key words
inertness, inertnessvendor, vendorwax, waxcolumn, columnmaltol, maltolprobes, probesbenchmarking, benchmarkingtest, testimproved, improvedagilent, agilentcolumns, columnsconsistency, consistencystandard, standarddecanal, decanalimprovement