Agilent 6850 Series II Network GC System - Specifications

Brochures and specifications | 2004 | Agilent TechnologiesInstrumentation
GC
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Method


The Agilent 6850 Series II Network GC system combines high-performance gas chromatography with a compact footprint and network connectivity. It addresses the need for reliable, automated, and versatile analysis in industrial, environmental, and pharmaceutical laboratories.

Objectives and Overview of the System


This document presents the specifications and capabilities of the Agilent 6850 Series II GC, highlighting its performance parity with larger models, network readiness, built-in autosampler control, and optional handheld interface.

Methodology and Instrumentation


The system employs precise electronic pneumatics control (EPC), programmable ovens with fast ramping, multiple inlet configurations, and interchangeable detectors. It supports cryogenic cooling and ambient compensation to achieve accurate temperature programming and stable baselines.

Used Instrumentation


  • GC Module: Single-channel 6850 Series II with LAN interface, controller for G2880 autosampler or 7683 autoinjector, optional handheld control.
  • Oven: Standard and fast oven modes; temperature range from ambient to 350 °C (–20 °C to –30 °C with cryo); six ramps with seven plateaus; automatic power-off on lid opening.
  • Inlets: Split/splitless (50–530 µm i.d.), purged-packed, programmable temperature vaporizer (PTV), programmable cool-on-column.
  • Detectors: FID, TCD, micro-ECD, single-wavelength FPD; temperature up to 375 °C; dynamic ranges from 10^5 to 10^7; data rates up to 200 Hz.
  • Valving Options: 6-port gas sampling or 4-port liquid sampling in heated compartment; rotary and diaphragm designs for varying chemical compatibilities.
  • Control Module: Optional handheld unit with graphical interface, method editing, real-time plot, diagnostics, and flash memory transfer.
  • Environmental and Power: Operating 15 °C–35 °C, 5–95% RH; power 100–230 V, 9–20 A; complies with CISPR, EN 55011, IEC, CSA, UL, ISO 9001.

Main Results and Discussion


The 6850 Series II GC delivers performance comparable to the Agilent 6890N while halving the instrument width. Fast ramp rates up to 350 °C/min and precise EPC enable complex temperature programs. Cryogenic cooling extends the low-temperature limit to –30 °C. Detector sensitivity and dynamic range support trace analysis. Integrated diagnostics and service methods facilitate maintenance, reducing downtime.

Benefits and Practical Applications


  • High throughput with rapid oven cool-down and fast programming.
  • Flexible inlet and detector options for diverse analytes and matrices.
  • Network and autosampler integration streamline data acquisition in QA/QC environments.
  • Compact design conserves bench space in clinical, environmental, and petrochemical labs.
  • Built-in diagnostics and service modes reduce maintenance complexity.

Future Trends and Applications


Advances may include further miniaturization, enhanced IoT connectivity for remote monitoring, greener cryogenic cooling, and expanded AI-driven diagnostics. Integration with laboratory information management systems and cloud-based data analysis will improve workflow efficiency and data integrity.

Conclusion


The Agilent 6850 Series II Network GC system offers a robust, versatile platform for modern analytical challenges. Its compact design, advanced control features, and broad application range make it a valuable tool for laboratories requiring reliable, high-performance gas chromatography.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent 6850 Series II Network GC System Specifications
Agilent 6850 Series II Network GC System Specifications
2010|Agilent Technologies|Brochures and specifications
Agilent 6850 Series II Network GC System Specifications Description The single-channel Agilent 6850 Series II Network GC system has similar state-of-the-art performance as the Agilent 6890N GC, but is only half as wide. The six-button, twoline local interface provides run…
Key words
temperature, temperatureramps, rampsoven, ovenbuilt, builtepc, epcpressure, pressureseptum, septumdodecanethiol, dodecanethioltributylphosphate, tributylphosphatepcoc, pcocvici, vicimicroseal, microsealmerlin, merlinvalves, valvesconforms
Agilent 6890N Network Gas Chromatograph (Specifications)
Agilent 6890N Network Gas Chromatograph (Specifications)
2002|Agilent Technologies|Brochures and specifications
Agilent 6890N Network Gas Chromatograph Specifications Dimensions and Average Weight - CSA/Nationally Recognized Test Laboratory (NRTL): UL 3101 • Height: 50 cm (19.7 in.) - International Electrotechnical Commission (IEC): 61010-1 • Width: 58 cm (22.8 in.) with EPC inlet and…
Key words
electronic, electronictemperature, temperaturepressure, pressurecontrol, controlpcoc, pcocnpd, npdfpd, fpdflow, flowmakeup, makeupsetpoint, setpointcapillary, capillaryepc, epctcd, tcdfid, fiddetectors
Agilent 7890B Gas Chromatograph - Data Sheet
Agilent 7890B Gas Chromatograph - Data Sheet
2013|Agilent Technologies|Brochures and specifications
Agilent 7890B Gas Chromatograph Data Sheet Chromatographic Performance* • Retention time repeatability < 0.008% or < 0.0008 min The combination of precise pneumatic and temperature control leads to extremely precise retention time reproducibility, which is the basis for all chromatographic…
Key words
epc, epccapillary, capillarypressure, pressurecontrol, controlbead, beaddetector, detectortemperature, temperatureinlet, inletflow, flowpurged, purgedweldment, weldmentcolumn, columninlets, inletspsia, psiablos
Agilent 7890A Network GasChromatograph - Data Sheet
Agilent 7890A Network GasChromatograph - Data Sheet
2011|Agilent Technologies|Brochures and specifications
Agilent 7890A Network Gas Chromatograph Data Sheet Chromatographic Performance* • Retention time repeatability < 0.008% or < 0.0008 min • Area repeatability < 1%RSD The Agilent 7890A is a state-of-the-art gas chromatograph that provides superior performance for all applications. Key…
Key words
epc, epccapillary, capillarypressure, pressurecontrol, controlbead, beaddetector, detectorinlet, inletflow, flowtemperature, temperaturepsia, psiacolumn, columnblos, blostcd, tcdcompensated, compensatedpurged
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike