Benefits of Using Programmed Temperature Vaporizers (PTVs) instead of Hot Split/Splitless Inlets for Measurements of Volatiles by Liquid, Headspace, and Solid Phase MicroExtraction (SPME) Techniques
Applications | 2001 | GERSTELInstrumentation
The accurate analysis of volatile organic compounds by gas chromatography is critical in many fields, including food quality, flavor and fragrance research, environmental monitoring and pharmaceutical analysis. In particular, minimizing thermal degradation and oxidative decomposition of labile analytes during sample introduction directly influences sensitivity, reproducibility and detection limits. Programmed Temperature Vaporizers (PTVs) offer an alternative to conventional hot split/splitless (S/SL) inlets, potentially reducing analyte loss and improving peak shapes in liquid, headspace (HS) and solid-phase microextraction (SPME) techniques.
This study compared a Gerstel CIS 4 PTV inlet to a traditional Agilent S/SL inlet for the measurement of volatile model compounds and real-world matrices. Benzaldehyde was used to explore evidence of thermal or oxidative degradation in hot inlets. Experiments included liquid injection, HS sampling of aqueous standards and complex matrices (cherry-flavored cola, coffee), and SPME injections to assess septum coring and background contamination.
Liquid and HS injections of benzaldehyde showed 50–116 % higher peak areas with the PTV compared to the hot S/SL inlet, indicating significant analyte loss in the latter. Lower reproducibility and deteriorated peak shape for thermally labile compounds were observed in S/SL mode. HS sampling of cherry cola and coffee confirmed improved sensitivity, sharper peaks and reduced background with PTV. The PTV’s cold venting mode flushed oxygen before vaporization, mitigating oxidative decomposition. SPME injections into a hot S/SL inlet rapidly cored septa, leading to increased chromatographic background and potential fiber breakage. Using a septumless head on the PTV avoided these issues.
Emerging sample introduction techniques may integrate PTV inlets with advanced cold trapping materials to further expand the volatility range. Automation of temperature programs could allow compound-specific inlet profiles. Coupling PTVs with novel enrichment sorbents or multidimensional chromatography promises higher sensitivity for trace-level analysis. Continued development of septumless interfaces will benefit SPME and large-volume injections in both research and quality-control laboratories.
Programmed Temperature Vaporizers offer clear advantages over conventional hot split/splitless inlets for the analysis of volatile and thermally sensitive compounds. By minimizing thermal and oxidative losses, sharpening chromatographic peaks and eliminating septum coring, PTV inlets improve recovery, detection limits and robustness across liquid, headspace and SPME techniques.
Heiden A.C., Kolahgar B., Pfannkoch E. "Benefits of Using Programmed Temperature Vaporizers (PTVs) instead of Hot Split/Splitless Inlets for Measurements of Volatiles by Liquid, Headspace, and Solid Phase MicroExtraction (SPME) Techniques," Gerstel AppNote 7/2001.
GC/MSD, HeadSpace, SPME, GC/SQ
IndustriesFood & Agriculture
ManufacturerAgilent Technologies, GERSTEL
Summary
Significance of the Topic
The accurate analysis of volatile organic compounds by gas chromatography is critical in many fields, including food quality, flavor and fragrance research, environmental monitoring and pharmaceutical analysis. In particular, minimizing thermal degradation and oxidative decomposition of labile analytes during sample introduction directly influences sensitivity, reproducibility and detection limits. Programmed Temperature Vaporizers (PTVs) offer an alternative to conventional hot split/splitless (S/SL) inlets, potentially reducing analyte loss and improving peak shapes in liquid, headspace (HS) and solid-phase microextraction (SPME) techniques.
Objectives and Study Overview
This study compared a Gerstel CIS 4 PTV inlet to a traditional Agilent S/SL inlet for the measurement of volatile model compounds and real-world matrices. Benzaldehyde was used to explore evidence of thermal or oxidative degradation in hot inlets. Experiments included liquid injection, HS sampling of aqueous standards and complex matrices (cherry-flavored cola, coffee), and SPME injections to assess septum coring and background contamination.
Methodology and Instrumentation
- Gas chromatograph: Agilent 6890 with 5973N mass selective detector
- Inlets: Gerstel CIS 4 PTV; Agilent hot S/SL inlet
- Sampler: Gerstel MPS 2 autosampler
- Column: 30 m HP-5MS (0.25 mm i.d., 0.25 µm film); He at 1.0 mL/min
- Liquid injection: 1 µL at 50 µL/s, split 20:1; PTV solvent vent mode at 20 °C, ramped to 300 °C
- Headspace: 2 mL injections from 85–90 °C sample; PTV venting vs. S/SL hot injection
- SPME: 23 ga. PDMS fiber; septum vs. septumless head comparison
Main Results and Discussion
Liquid and HS injections of benzaldehyde showed 50–116 % higher peak areas with the PTV compared to the hot S/SL inlet, indicating significant analyte loss in the latter. Lower reproducibility and deteriorated peak shape for thermally labile compounds were observed in S/SL mode. HS sampling of cherry cola and coffee confirmed improved sensitivity, sharper peaks and reduced background with PTV. The PTV’s cold venting mode flushed oxygen before vaporization, mitigating oxidative decomposition. SPME injections into a hot S/SL inlet rapidly cored septa, leading to increased chromatographic background and potential fiber breakage. Using a septumless head on the PTV avoided these issues.
Benefits and Practical Applications
- Reduced analyte degradation in liquid and HS analyses
- Improved peak shapes and signal-to-noise ratios, lowering detection limits
- Enhanced reproducibility for labile volatiles
- Elimination of septum coring and background buildup in SPME applications
- Compatibility with large-volume splitless HS injections without flow restrictions
Future Trends and Opportunities
Emerging sample introduction techniques may integrate PTV inlets with advanced cold trapping materials to further expand the volatility range. Automation of temperature programs could allow compound-specific inlet profiles. Coupling PTVs with novel enrichment sorbents or multidimensional chromatography promises higher sensitivity for trace-level analysis. Continued development of septumless interfaces will benefit SPME and large-volume injections in both research and quality-control laboratories.
Conclusion
Programmed Temperature Vaporizers offer clear advantages over conventional hot split/splitless inlets for the analysis of volatile and thermally sensitive compounds. By minimizing thermal and oxidative losses, sharpening chromatographic peaks and eliminating septum coring, PTV inlets improve recovery, detection limits and robustness across liquid, headspace and SPME techniques.
References
Heiden A.C., Kolahgar B., Pfannkoch E. "Benefits of Using Programmed Temperature Vaporizers (PTVs) instead of Hot Split/Splitless Inlets for Measurements of Volatiles by Liquid, Headspace, and Solid Phase MicroExtraction (SPME) Techniques," Gerstel AppNote 7/2001.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Theory and Key Principles Series: Session 4 – Advanced Liquid Injection Techniques
2020|Shimadzu|Presentations
Shimadzu UK Theory & Key Principles Series – GC Session 4 Theory and Key Principles Series Gas Chromatography (GC) Session 4 – Advanced Liquid Injection Techniques Shimadzu UK Theory & Key Principles Series – GC Session 4 Introduction Welcome to…
Key words
ptv, ptvoci, ocisplitless, splitlesssplit, splitlabile, labilespl, splprogrammable, programmablediscrimination, discriminationvaporisation, vaporisationhot, hotinjections, injectionscold, coldcoc, cocboiling, boilingthermally
Cooled Injection System - CIS
|GERSTEL|Brochures and specifications
Cooled Injection System CIS Universal inlet for all injection techniques used in GC- and GC/MS GERSTEL Cooled Injection System CIS Universal inlet for all injection techniques used in GC and GC/MS The GERSTEL Cooled Injection System is the most widely…
Key words
gerstel, gerstelliner, linermaestro, maestrocis, cisinjection, injectioncryofocusing, cryofocusingdirty, dirtyalex, alexinlet, inletthanks, thanksoperation, operationlvi, lviheating, heatingelex, elexslh
GC Inlets - An Overview
2017|Agilent Technologies|Presentations
GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where to Begin??? What are the requirements of the method? Trace level…
Key words
splitless, splitlesssplit, splitinlet, inletinjections, injectionssolvent, solventpulsed, pulsedvent, ventcoc, cocdiscrimination, discriminationcolumn, columncold, coldpacked, packedliner, linerinjection, injectionmmi
Understanding the Inlets - Which one is more appropriate for your method?
2017|Agilent Technologies|Presentations
Understanding the GC Inlet Which one is more appropriate for your method? Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where to Begin??? What…
Key words
splitless, splitlesssplit, splitinlet, inletinjections, injectionssolvent, solventpulsed, pulsedvent, ventcoc, cocdiscrimination, discriminationcolumn, columncold, coldpacked, packedliner, linerinjection, injectionmmi