Significance of Intuvo 9000 GC Site Preparation


Proper site preparation is the foundation for maximizing uptime, analytical precision and instrument longevity. By meeting spatial, environmental and utility prerequisites before installation, laboratories reduce startup delays and avoid performance issues that can arise from inadequate power, poor venting or unstable gas supplies.

Objectives and Overview of the Checklist


The Agilent Intuvo 9000 GC Site Preparation Checklist guides users through all necessary tasks prior to delivery and service activation. It ensures that:
  • Bench space, weight capacity and clearance dimensions are adequate.
  • Environmental conditions (temperature, humidity, vibration) are within specification.
  • Utility connections—electrical outlets, gas lines, plumbing and venting—are in place.
  • Required operating supplies, consumables and safety measures are available.

Used Instrumentation


The primary instrument addressed is the Agilent Intuvo 9000 Gas Chromatograph. Optional modules and accessories include:
  • Detectors: FID, TCD, ECD, FPD, NPD
  • Sample introduction: Split/Splitless inlet, Multimode Inlet, 7693/7697 ALS injectors
  • Gas purification: Gas Clean filter system
  • Support hardware: Two-stage regulators, Swagelok fittings, copper or stainless steel tubing

Main Requirements and Conditions


  • Laboratory bench space: 86 cm minimum depth, 25 cm clearance behind oven, no overhanging shelves; support up to 80 kg.
  • Environmental conditions: Operating range 15–35 °C, 15–90 % RH, stable atmosphere, altitudes ≤2438 m.
  • Heat dissipation: Up to 5285 BTU/h (5576 kJ/h) at 240 VAC; ensure adequate ventilation or exhaust duct.
  • Venting: Oven exhaust duct adds 12.5 cm to the back; dedicated exhaust or fume hood for detector and inlet vents when using hydrogen.
  • Power: Dedicated circuit with 120 VAC/15 A or 220–240 VAC/10 A outlets; separate outlets for PC, monitor, printer.
  • Gas supplies: Carrier and detector gases 99.9995 % purity, zero-grade air; makeup gas for capillary detectors; hydrogen safety protocols.
  • Plumbing: Regulators with 1/8″ Swagelok fittings; new pre-cleaned tubing; shut-off valves, traps for moisture/oxygen/hydrocarbons.
  • Operating supplies: Septa, liners, ferrules, O-rings, detector jets/beads, vials and syringes for sample prep.

Benefits and Practical Use of Proper Preparation


Adherence to the checklist minimizes installation delays, ensures safety when handling flammable gases and unstable pressures, and promotes reproducible chromatography. Well-prepared sites reduce the risk of leaks, electrical faults and thermal stress to critical components.

Future Trends and Possibilities for Utilization


As laboratory automation and remote monitoring expand, site preparation will increasingly incorporate standardized infrastructure for cloud-connected diagnostics. Advances in on-demand gas generation and predictive maintenance software will further streamline instrument commissioning and reduce manual interventions.

Conclusion


The Agilent Intuvo 9000 GC Site Preparation Checklist is an essential tool for achieving a seamless installation. By systematically verifying space, utilities, supplies and safety measures in advance, laboratories can accelerate time to data and safeguard instrument performance over its service life.

References


  • Agilent Intuvo 9000 Gas Chromatograph Site Preparation Guide (Agilent Document D0013615, Revision 2.03).
  • Hydrogen Safety Guide (shipped with the instrument).

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent Intuvo 9000 Gas Chromatograph - Site Preparation Checklist
Agilent CrossLab Start-Up Services Agilent Intuvo 9000 Gas Chromatograph Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start-Up is focused on helping customers shorten the time it takes to start realizing the full value of…
Key words
hydrogen, hydrogensupplies, suppliesnitrogen, nitrogengas, gaspsi, psiamps, ampssupply, supplysite, siteplumbing, plumbingcarrier, carrierhelium, heliumtermination, terminationcustomer, customerspecial, specialnotes
Agilent 7890 Gas Chromatograph - Site Preparation Checklist
Agilent CrossLab Start-Up Services Agilent 7890 Gas Chromatograph Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start-Up is focused on helping customers shorten the time it takes to start realizing the full value of their…
Key words
nitrogen, nitrogensupplies, supplieshydrogen, hydrogentermination, terminationpsi, psiinlet, inletgas, gasinstallation, installationpart, parthelium, heliumdissipation, dissipationpower, powersite, sitecountry, countryamps
Intuvo 9000 GC - Site Preparation Checklist
Intuvo 9000 GC - Site Preparation Checklist
2016|Agilent Technologies|Manuals
Intuvo 9000 GC Site Preparation Checklist Thank you for purchasing an Agilent Instrument. To get you started and to assure a successful and timely installation of your 9000 GC, please refer to this site prep checklist. Correct site preparation is…
Key words
technologies, technologieshydrogen, hydrogensupplies, suppliesnitrogen, nitrogenagilent, agilenthelium, heliumplumbing, plumbinggas, gasamps, ampscarrier, carrierspecial, specialair, airpcm, pcmdissipation, dissipationdetector
Agilent 8860 Gas Chromatograph - Site Preparation Checklist
Agilent CrossLab Start-Up Services Agilent 8860 Gas Chromatograph Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start-Up is focused on helping customers shorten the time it takes to start realizing the full value of their…
Key words
termination, terminationsite, sitehydrogen, hydrogendissipation, dissipationamps, ampsrequirements, requirementsgas, gascustomer, customerspecial, specialheat, heatplug, plugpower, poweruntied, untiedinstrument, instrumentpart
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike