Analytical evaluation of the Agilent IDP-10 Dry Scroll Vacuum Pump and Oil Roughing Pump on the Agilent GC Intuvo 9000 coupled to 7010B Triple Quad Mass Spectrometry.

Applications | 2018 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Industries
Food & Agriculture
Manufacturer
Agilent Technologies

Summary

Significance of the topic


The reliable detection of pesticide residues in food matrices is critical for regulatory compliance and consumer safety ensuring trace level monitoring in complex samples such as fruit extract

Objectives and overview


This study evaluates the Agilent IDP-10 Dry Scroll Vacuum Pump performance against a conventional oil roughing pump within an Agilent GC Intuvo 9000 system coupled to a 7010B Triple Quadrupole MS focusing on multi residue pesticide analysis in lemon matrix

Used instrumentation


  • Agilent Intuvo 9000 Gas Chromatograph
  • Agilent 7010B Triple Quadrupole Mass Spectrometer
  • Agilent IDP-10 Dry Scroll Vacuum Pump
  • Conventional oil roughing pump
  • Ceramic homogenizer and QuEChERS dispersive SPE kits

Methodology


Ten gram homogenized lemon sample extracted with acetonitrile and NaOH followed by QuEChERS cleanup then analyzed by pulsed splitless injection on GC MS MS with tuning performed for each pump configuration Calibration was conducted at eight concentration levels from 0.2 to 50 ug per liter in matrix standards

Main results and discussion


Vacuum pressure and tune parameters were essentially equivalent for both pumps within recommended limits Calibration curves showed r squared values above 0.99 across all analytes IDP 10 pump delivered improved repeatability with lower RSD values and enhanced signal to noise ratios for the majority of compounds while peak shape remained consistent between configurations

Benefits and practical applications


The oil free IDP 10 pump offers reduced maintenance and lower acoustic noise environmental advantages along with reliable vacuum performance yielding better precision and sensitivity ideal for routine QA QC and high throughput pesticide surveillance

Future trends and opportunities


Integration of compact scroll pumps into automated workflows Internet of Things enabled monitoring predictive maintenance advances in pump materials may further enhance vacuum stability and broaden application to diverse sample types requiring oil free operation

Conclusion


The Agilent IDP 10 Dry Scroll Pump matches conventional roughing pump in vacuum stability and tuning performance while providing superior analytical precision and signal quality making it a robust choice for multi residue pesticide analysis

Reference


  • Agilent Technologies Application Note 5991 9201EN printed March 2018

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Pesticide Residue Analysis with Automated EDGE Extraction System and Multi-Layer GC/MS Sandwich Injection
Poster Reprint ASMS 2021 Poster number MP076 Pesticide Residue Analysis with Automated EDGE Extraction System and Multi-Layer GC/MS Sandwich Injection Anastasia Andrianova,1 Jessica Westland,1 Bruce Quimby,1 Alicia Stell,2 Benedict Liu,2 Candice Cashman2 Agilent Technologies, Inc. Wilmington DE 2 CEM Corporation,…
Key words
edge, edgequechers, quechersmethyl, methylendosulfan, endosulfanextraction, extractionsandwich, sandwichbhc, bhcethyl, ethylendrin, endrinbromfenvinfos, bromfenvinfosmatched, matchedbromophos, bromophosmatrix, matrixistd, istdpirimiphos
Multi-Residue Method for Determination of 350 Pesticides in Food Extracts by utilizing new GC-MS/MS technology
Multi-Residue Method for Determination of 350 Pesticides in Food Extracts by utilizing new GC-MS/MS technology Thierry Faye*, Joerg Riener Agilent Technologies *Corresponding author - E-mail: [email protected]; Phone: +33643477118 Introduction Traditionally pesticide residues in foods have been monitored with multi-residue methods…
Key words
methyl, methylfenthion, fenthionethyl, ethyldisulfoton, disulfotonsulfone, sulfonesulfoxide, sulfoxideallethrin, allethrinparaoxon, paraoxontetramethrin, tetramethrinbromophos, bromophosisofenphos, isofenphospirimicarb, pirimicarbphorate, phoratepirimiphos, pirimiphosparathion
Multi-Residue Method for Determination of 350 Pesticides in Food Extracts by  utilizing new GC-MS/MS technology
Multi-Residue Method for Determination of 350 Pesticides in Food Extracts by utilizing new GC-MS/MS technology Thierry Faye*, Joerg Riener Agilent Technologies *Corresponding author - E-mail: [email protected]; Phone: +33643477118 Introduction Traditionally pesticide residues in foods have been monitored with multi-residue methods…
Key words
methyl, methylfenthion, fenthionethyl, ethyldisulfoton, disulfotonsulfone, sulfonesulfoxide, sulfoxideallethrin, allethrinparaoxon, paraoxontetramethrin, tetramethrinbromophos, bromophosisofenphos, isofenphospirimicarb, pirimicarbphorate, phoratepirimiphos, pirimiphosparathion
Pesticides Analysis Using the Agilent 5977A Series GC/MSD
Pesticides Analysis Using the Agilent 5977A Series GC/MSD
2013|Agilent Technologies|Applications
Pesticides Analysis Using the Agilent 5977A Series GC/MSD Application Note Food Testing and Agriculture Authors Abstract Jia-jia Wu and Wen-wen Wang A method has been developed using the Agilent 5977A Series GC/MSD that can Agilent Technologies Co. Ltd (China) deliver…
Key words
bhc, bhcorganophosphorus, organophosphoruspyrethroid, pyrethroidparathion, parathionorganochlorine, organochlorineisocarbophos, isocarbophosflucythrinate, flucythrinatemethyl, methylfluvalinate, fluvalinatetau, taucyfluthrin, cyfluthrinisofenphos, isofenphoscyhalothrin, cyhalothrinfenvalerate, fenvalerateprofenofos
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike