ToxProPlus Reporting Software Package

Manuals | 2005 | Agilent TechnologiesInstrumentation
Software
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Accurate and efficient review of gas chromatography–mass spectrometry (GC–MS) data underpins decision making in environmental, clinical, pharmaceutical, and industrial analyses. Automated and customizable reporting tools accelerate data interpretation, reduce manual errors, and facilitate timely quality-control actions.
  • High-throughput screening expedites the identification of target and unknown compounds.
  • Automated ion ratio summaries ensure compliance with regulatory thresholds.
  • Template-driven layouts enhance consistency and ease of integration with downstream workflows.

Purpose and Overview


This document outlines three complementary reporting modules provided with Varian/Agilent MS Workstation Version 6.5:
  • MultiCpd – a flexible Microsoft Access-based report generator for targeted compounds, unknowns, and tentatively identified compounds (TICs).
  • Ion Ratio Summary – a recalculation list-driven custom report summarizing qualifier-to-quantifier ion ratios, calibration parameters, and fit metrics.
  • Screening Reports – a condensed graphic-only template displaying up to 30 chromatogram/spectrum frames per page for rapid visual review.

Methodology and Instrumentation


Raw GC–MS data are processed and quantitated in MS Data Review or System Control using a well-configured Varian MS method:
  • Peak integration parameters (width, slope sensitivity, baseline correction) are optimized in the compound table.
  • Calibration is performed using internal or external standards with appropriate regression weighting and origin handling.
  • Qualifier ion ratios and spectral fit thresholds ensure reliable compound confirmation.
  • MultiCpd templates (.swt) are created or cloned from master Access databases (.mdb), defining graphic and text layouts via customizable report templates.

Key Results and Discussion


The three reporting modules demonstrate distinct strengths:
  • MultiCpd delivers tailored multipage reports with combined graphics (chromatograms, spectra) and textual fields across 19 template types (Sample, Chromatogram, Target, TIC, Unknown).
  • Ion Ratio Summary computes mean Q1/Q and Q2/Q values from calibration runs, applies ±20% acceptance limits, and highlights outliers for each analyte.
  • Screening Reports generate up to 30 compound frames per page to flag integration or processing issues before detailed reporting.

Benefits and Practical Applications


These reporting tools offer:
  • Interactive preview and editing of report layouts without altering original data files.
  • Automated printing or file export triggered via Sample List or Recalc List AutoLink in System Control.
  • Support for both MS and auxiliary .RUN chromatogram plots (e.g., UV detectors) and MS/MS channels.
  • Text-only exports for further processing in spreadsheets or LIMS.

Future Trends and Opportunities


Advances may include:
  • Integration with cloud-based LIMS for centralized report access.
  • Enhanced library search algorithms leveraging high-resolution MS data.
  • Machine-learning-driven pattern recognition for unknown identification.
  • Dynamic web-friendly HTML or JSON output for real-time dashboards.

Conclusion


Varian/Agilent’s MultiCpd, Ion Ratio Summary, and Screening report packages provide a comprehensive, customizable framework for GC–MS data reporting. Their template-based design enables rapid deployment for routine workflows while permitting advanced customization for specialized applications.

Instrumentations


The reporting framework was implemented using:
  • Varian/Agilent MS Workstation Version 6.5 with MS Data Review and System Control modules.
  • Saturn GC/MS Workstation hardware for data acquisition.
  • Microsoft Access 2000 for report template development.
  • Windows 98/NT/2000 operating environments.

Reference


No external literature references were provided in the source document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Star Custom Report Writer
Star Custom Report Writer
2002|Agilent Technologies|Manuals
NOTICE: Varian, Inc. was acquired by Agilent Technologies in May 2010. This document is provided as a courtesy but is no longer kept current and thus will contain historical references to Varian. For more information, go to www.agilent.com/chem. Varian Analytical…
Key words
report, reportwriter, writerstar, starobject, objectcustom, customtemplate, templatefile, fileobjects, objectstemplates, templatesdata, datacorrective, correctiveselect, selectyou, youprint, printpage
Agilent Technologies Agilent MassHunter Workstation Software Report Designer Add-in
Agilent MassHunter Workstation Software Report Designer Add-in Quick Start Guide What is the Agilent MassHunter Workstation Software Report Designer Add-in? 2 Report Designer UI elements 3 Getting Started 5 Customizing a template 13 Using the Advanced Properties dialog box 24…
Key words
designer, designeradd, addreport, reportmasshunter, masshuntertemplate, templateguide, guideagilent, agilentquick, quickstart, startcustomizing, customizingtable, tableworkstation, workstationgraphics, graphicsgetting, gettingmenu
5973N MSD 6890 GC Quick Reference
5973N MSD 6890 GC Quick Reference
2001|Agilent Technologies|Manuals
5973N MSD 6890 GC Quick Reference Learning About Your System Online Help 5973N Maintenance CD-ROM Use the online help to learn about instrument control, data acquisition, data analysis, methods, sequencing, tuning, and how to use system commands and variables. Troubleshooting…
Key words
view, viewselect, selectmsd, msdhelp, helptune, tunefile, fileabort, abortmenus, menusyou, yousubtract, subtracttoo, toobutton, buttonexit, exitlets, letsdisplay
6890 GC / 5973N MSD (Quick Reference)
6890 GC / 5973N MSD (Quick Reference)
2001|Agilent Technologies|Manuals
5973N MSD 6890 GC Quick Reference Learning About Your System Online Help 5973N Maintenance CD-ROM Use the online help to learn about instrument control, data acquisition, data analysis, methods, sequencing, tuning, and how to use system commands and variables. Troubleshooting…
Key words
select, selectview, viewmsd, msdhelp, helptune, tunefile, fileabort, abortmenus, menusyou, youtoo, toosubtract, subtractbutton, buttonlets, letsexit, exitdisplay
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike