Analysis of butter fat

Applications | 2016 | Trajan ScientificInstrumentation
GC, GC columns, Consumables
Industries
Manufacturer
Trajan Scientific
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of triglyceride standards
2018|Trajan Scientific|Applications
APPLICATION NOTE Analysis of triglyceride standards AN-0165-G_RevB © Trajan Scientific Australia Pty Ltd 06/2018 HT5 Column part number 054655 Phase HT5 Carrier gas H2, 2 psi Column 6 m x 0.53 mm x 0.1 μm Detector FID Initial temperature 60°C,…
Key words
triglyceride, triglyceridecolumn, columntemperature, temperaturefid, fidfinal, finalinitial, initialpart, partcarrier, carriersensitivity, sensitivitystandards, standardsdetector, detectornumber, numbermode, moderate, ratephase
Analysis of fatty acid methyl esters (FAME)
2017|Trajan Scientific|Applications
APPLICATION NOTE Analysis of fatty acid methyl esters (FAME) HT5 Column part number 054632 Phase HT5 Final temperature 300°C Column 25 m x 0.22 mm x 0.1 μm Detector FID Initial temperature 120°C Carrier gas H2, 10 psi Rate 3°C/min…
Key words
fame, fameesters, estersfatty, fattytemperature, temperaturefid, fidfinal, finalcolumn, columnmethyl, methylinitial, initialsplit, splitpart, partcomponents, componentscarrier, carrieracid, aciddetector
Analysis of polychlorinated dibenzofurans
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of polychlorinated dibenzofurans BPX5 Column Part Number 054114 Phase BPX5 Rate 3 5°C/min to 330°C Column 50 m x 0.22 mm x 0.25 μm Final temperature 330°C Initial temperature 180°C, 2 min Carrier gas He, 30 psi…
Key words
dibenzofurans, dibenzofuranspolychlorinated, polychlorinatedheptachlorodibenzofurans, heptachlorodibenzofuranshexachlorodibenzofurans, hexachlorodibenzofuranspentachlorodibenzofurans, pentachlorodibenzofuranstetrachlorodibenzofurans, tetrachlorodibenzofuransoctachlorodibenzofurans, octachlorodibenzofuransmin, minnote, notetemperature, temperatureapplication, applicationfinal, finalcolumn, columninitial, initialpart
Analysis of volatiles from drinking water
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of volatiles from drinking water BP624 Column part number 054835 Phase BP624 Final temperature 210°C, 1 min Column 50 m x 0.53 mm x 3.0 μm Detector MS Initial temperature 35°C, 2 min Injection mode Purge &…
Key words
volatiles, volatilesdrinking, drinkingbromofluorobenzene, bromofluorobenzeneacrylonitrile, acrylonitriletetrachloroethene, tetrachloroethenetrichloroethene, trichloroethenedibromochloromethane, dibromochloromethanebromodichloromethane, bromodichloromethanebromoform, bromoformchlorobenzene, chlorobenzenetetrachloride, tetrachloridevinyl, vinylwater, watermethylene, methyleneethylbenzene
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike