A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants
Applications | 2015 | ShimadzuInstrumentation
The presence of phthalate esters and brominated flame retardants in polymer-based products raises health and environmental concerns as well as regulatory compliance challenges. Rapid screening techniques are critical for industries to meet global restrictions such as RoHS, CPSIA, TSCA and relevant FDA and EU directives.
This application note evaluates a solvent-free, pyrolysis-GC/MS screening method (Py-Screener package) for the simultaneous detection and semi-quantification of seven phthalate esters and eleven brominated flame retardants in polymer matrices. The study leverages pre-registered methods, calibration standards and software tools to streamline data acquisition and QA/QC review.
Analysis of three polymer samples (“Blue Conveyor”, “White Conveyor”, “Gasket”) and a blank revealed DINP and DIDP concentrations of ~3% and ~0.7% respectively in conveyor samples, exceeding common 0.1% regulatory thresholds. The gasket sample showed only trace levels (~0.03% DINP, ~0.02% DIDP). Other target analytes were below detection limits. SIM mode significantly reduced background noise and facilitated clear peak identification.
The pyrolysis-GC/MS approach may be paired with traditional solvent extraction and capillary liquid injection for full quantitative analysis. Future enhancements could involve tandem MS, expanded compound libraries, automated data review and higher-throughput sampling to address evolving regulatory lists and emerging contaminants.
The Py-Screener pyrolysis-GC/MS method provides a fast, solvent-free solution for regulatory screening of phthalate esters and brominated flame retardants in polymer products. Its ease of use and integrated software support make it well-suited for quality control and compliance laboratories.
GC/MSD, Thermal desorption, GC/SQ
IndustriesMaterials Testing
ManufacturerShimadzu, Frontier Lab
Summary
Significance of the Topic
The presence of phthalate esters and brominated flame retardants in polymer-based products raises health and environmental concerns as well as regulatory compliance challenges. Rapid screening techniques are critical for industries to meet global restrictions such as RoHS, CPSIA, TSCA and relevant FDA and EU directives.
Objectives and Study Overview
This application note evaluates a solvent-free, pyrolysis-GC/MS screening method (Py-Screener package) for the simultaneous detection and semi-quantification of seven phthalate esters and eleven brominated flame retardants in polymer matrices. The study leverages pre-registered methods, calibration standards and software tools to streamline data acquisition and QA/QC review.
Used Instrumentation
- Shimadzu GCMS-QP2010 Ultra mass spectrometer
- Frontier Multi-Shot EGA/PY-3030D pyrolyzer
- AS-1020E Auto-Shot sampler
- UA-PBDE capillary column (15 m × 0.25 mm × 0.05 µm)
Methodology
- Sample preparation: Cutting ~0.5 mg polymer pieces directly into micro-furnace cups without solvents.
- Pyrolysis program: 200 °C → 300 °C at 20 °C/min (5 min), then 300 °C → 340 °C at 5 °C/min (9 min); transfer line held 100 °C above furnace up to 300 °C.
- Gas chromatography: Initial hold at 80 °C, ramp at 20 °C/min to 300 °C (5 min hold); injector at 300 °C with 50:1 split; helium carrier at 1 mL/min constant flow.
- Mass spectrometry: Combined full scan (50–1000 amu) and SIM acquisition with fast loop times (0.45 s total) for sensitive detection of signature ions.
- Calibration and retention time adjustment: One-point semi-quantitation at highest standard concentrations (1000 ppm for phthalates; 26–780 ppm for PBDEs) using an Automatic Adjust of Retention Time (AART) hydrocarbon mix.
Main Results and Discussion
Analysis of three polymer samples (“Blue Conveyor”, “White Conveyor”, “Gasket”) and a blank revealed DINP and DIDP concentrations of ~3% and ~0.7% respectively in conveyor samples, exceeding common 0.1% regulatory thresholds. The gasket sample showed only trace levels (~0.03% DINP, ~0.02% DIDP). Other target analytes were below detection limits. SIM mode significantly reduced background noise and facilitated clear peak identification.
Benefits and Practical Applications
- Eliminates lengthy solvent extraction and associated chemical hazards.
- Delivers rapid, semi-quantitative screening to support compliance testing workflows.
- Includes pre-configured instrument methods, calibration curves, standards and QA/QC software for efficient method deployment.
Future Trends and Possibilities
The pyrolysis-GC/MS approach may be paired with traditional solvent extraction and capillary liquid injection for full quantitative analysis. Future enhancements could involve tandem MS, expanded compound libraries, automated data review and higher-throughput sampling to address evolving regulatory lists and emerging contaminants.
Conclusion
The Py-Screener pyrolysis-GC/MS method provides a fast, solvent-free solution for regulatory screening of phthalate esters and brominated flame retardants in polymer products. Its ease of use and integrated software support make it well-suited for quality control and compliance laboratories.
Reference
- Directive 2002/95/EC. RoHS.
- Public Law 110–314. Consumer Product Safety Improvement Act of 2008.
- Directive 2005/84/EC. EU restrictions on specific phthalates.
- U.S. EPA Phthalates Action Plan under TSCA.
- FDA Guidance on limiting phthalates as excipients in CDER-regulated products.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants
2016|Shimadzu|Posters
PO-CON1616E A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters and Brominated Flame Retardants Pittcon 2016 2290-12 Nicole Lock, Laura Chambers, Andy Sandy, Ian Duffy Shimadzu Scientific Instruments, Columbia, MD, USA A Pyrolysis-GC/MS Screening System for Analysis of Phthalate Esters…
Key words
phthalate, phthalatebrominated, brominatedretardants, retardantspyrolysis, pyrolysisesters, estersflame, flamedidp, didpdinp, dinpscreening, screeninglabsolution, labsolutionconveyor, conveyorscreener, screenersim, simpolymer, polymerppm
Electronics & Chemicals - Application Notebook
2019|Shimadzu|Guides
C10G-E070 Electronics & Chemicals Solutions for Electronics & Chemicals Application Notebook Introduction Both inorganic and organic analyses are indispensable for electronics industry and related chemical industries. Purposes of analysis are wide ranging, and data generated can give much insight for…
Key words
contents, contentsback, backmeasurement, measurementanalysis, analysislight, lighttransmittance, transmittancefilm, filmreflectance, reflectancespectra, spectraedx, edxftir, ftirnews, newssample, samplewavelength, wavelengthusing
Comparison of Screening Method (Py-GC/MS) and Quantitative Method (Solvent Extraction–GC/MS) for Phthalate Esters Analysis
2016|Shimadzu|Applications
C146-E303 Technical Report Comparison of Screening Method (Py-GC/MS) and Quantitative Method (Solvent Extraction–GC/MS) for Phthalate Esters Analysis Jae Woo Kim1, Hye Mi Moon1, Fumitaka Maruyama2, Shigehiro Fujimaki2, Yukihiko Kudo3, Yuki Sakamoto3, Haruhiko Miyagawa3, Katsuhiro Nakagawa3 A b s tra c…
Key words
phthalate, phthalatescreener, screenerextraction, extractiondehp, dehpesters, estersscan, scansolvent, solventbbp, bbpsim, simsoxhlet, soxhletdbp, dbpevent, eventmode, modedissolution, dissolutionmethod
Analysis of Brominated Flame Retardants and Phthalate Esters In Ploymers Under the Same Conditions Using a Pyrolysis GC-MS System (2) - Phthalate Esters -
2012|Shimadzu|Applications
LAAN-J-MS-E048 GC-MS Gas Chromatograph - Mass Spectrometer Analysis of Brominated Flame Retardants and Phthalate Esters In Ploymers Under the Same Conditions Using a Pyrolysis GC-MS System (2) - Phthalate Esters - 48 In recent years, an analysis method is required…
Key words
phthalate, phthalateesters, esterssim, simdidp, didpdinp, dinpdehp, dehpscan, scanploymers, ploymersevent, eventmode, modedop, dopunregulated, unregulateddibp, dibpquantitating, quantitatingbbp