Mira P Raman - Product manual

Manuals | 2021 | MetrohmInstrumentation
RAMAN Spectroscopy
Industries
Manufacturer
Metrohm

Summary

Importance of the topic


The Mira P handheld Raman spectrometer offers rapid, non-destructive identification and verification of chemical and pharmaceutical samples in both field and laboratory settings. Its portability and high-performance Raman analysis address critical needs in quality control, regulatory compliance, and on-site hazard identification.

Objectives and Document Overview


This product manual aims to guide users through every aspect of the Mira P instrument: from safety precautions and initial configuration to routine operation, calibration, maintenance, and disposal. It provides a structured workflow for efficient deployment and consistent results.

Methodology


The manual outlines the standard operating procedure: install batteries or connect via USB, power on the device, log in, select an operating procedure in Mira Cal software, attach the appropriate Smart Tip, enter sample identifiers (manually or via barcode), arm the laser, and acquire Raman spectra. Calibration and system suitability tests ensure ongoing accuracy.

Used Instrumentation


  • Mira P handheld Raman analyzer with Orbital Raster Scan (ORS) technology
  • Smart Tips: Calibrate/Verify Attachment (CVA), Short, Long, and Extra Long Working Distance lenses (SWD, LWD, XLWD)
  • Accessories: Vial Holder, Tablet Holder, Contact Ball-Probe, Right Angle Attachment
  • Power options: AA batteries (lithium or NiMH) or powered USB connection
  • Mira Cal P software for instrument configuration, calibration, and data management

Main Findings and Discussion


The Mira P’s smartphone-sized form factor, glove-compatible touchscreen, and modular Smart Tip system enable versatile sampling of solids, liquids, powders, and packages. Safety features—laser class 3B warnings, interlock mechanisms, and protective glasses requirements—ensure compliance with IEC 60825-1. The device supports rapid screening with minimal sample preparation.

Benefits and Practical Applications


Key advantages include portability, fast turnaround, non-destructive analysis, and easy integration with spectral libraries. Applications span pharmaceutical quality assurance, forensic field testing, hazardous material identification, and industrial process monitoring.

Future Trends and Potential Uses


Emerging developments may feature expanded AI-driven spectral interpretation, cloud-based data sharing, enhanced miniaturization for wearable or drone-mounted deployments, and broader spectral database coverage for novel materials.

Conclusion


This manual equips operators with comprehensive instructions to leverage the Mira P’s capabilities safely and effectively, ensuring reliable Raman analysis in diverse environments.

References


  • IEC 60825-1:2014 Safety of laser products
  • 21 CFR 1040.1 & 1040.11, U.S. FDA performance standards for laser products
  • Laser Notice No. 50, U.S. FDA, 2007

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Metrohm MIRA DS Product manual
Metrohm MIRA DS Product manual
2021|Metrohm|Manuals
MIRA DS 2.926.00XX Product manual 8.926.8001EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA DS 2.926.00XX Firmware version 8.0.3.40 or higher Product manual 8.926.8001EN / 2021-09-15 Technical Communication Metrohm…
Key words
laser, laserattachment, attachmentmira, mirawarning, warningnotice, noticesmart, smarttips, tipsoperation, operationdistance, distancepowerpack, powerpacktip, tipworking, workingselect, selectusb, usbradiation
Metrohm MIRA XTR DS Product manual
MIRA XTR DS 2.926.01XX Product manual 8.0926.8005EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA XTR DS 2.926.01XX Firmware version 8.0.3.40 or higher Product manual 8.0926.8005EN / 2021-09-15 Technical…
Key words
mira, miraattachment, attachmentlaser, laserwarning, warningnotice, noticesmart, smarttips, tipsxtr, xtroperation, operationdistance, distancepowerpack, powerpacktip, tipworking, workingleft, leftacquiring
Metrohm Misa Raman - Product Manual
Misa Product Manual 8.950.8001EN / 2020-06-26 Metrohm AG Ionenstrasse CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Misa Firmware version 10.0.1.0 or higher Product Manual 8.950.8001EN / 2020-06-26 Technical Communication Metrohm…
Key words
misa, misawarning, warningcal, calnotice, noticebattery, batterysafety, safetyusb, usblaser, laserdanger, dangersmart, smartindicator, indicatortips, tipssers, sersradiation, radiationproduct
Mira Flex Packages
Mira Flex Packages
2019|Metrohm|Brochures and specifications
Mira Flex Packages Customized Metrohm Instant Raman Analyzers (Mira) for your unique applications Mira Flex – identification and verification of materials made fast and easy 02 Handheld Mira devices make identification and verification of materials fast, easy, and reliable –…
Key words
mira, miraflex, flexattachments, attachmentsattachment, attachmentraman, ramanverification, verificationcustomizable, customizablestandoff, standoffpackages, packageslaser, laserholder, holdersers, serssmart, smartbags, bagsball
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike