Determination of Free Glycerol in Fatty Acid Methyl Esters and Biodiesel according to EN 14106

Applications |  | SCION InstrumentsInstrumentation
GC
Industries
Energy & Chemicals
Manufacturer
SCION Instruments

Summary

Importance of the Topic

Determination of free glycerol in biodiesel is essential to ensure fuel quality and engine performance. Traces of glycerol can lead to filter clogging, injector fouling and non-compliance with international specifications such as ASTM D6751 and EN 14214. Reliable quantification supports quality control in production and blending operations.

Objectives and Study Overview

This application investigates the performance of a SCION 456 GC-FID system configured according to EN-14106. It aims to validate the method’s accuracy, precision and repeatability for measuring free glycerol content in fatty acid methyl esters (FAMEs) within the specified range of 0.005–0.070% mass.

Methodology and Instrumentation

Sample preparation involved weighing 3.5 g of biodiesel into a test tube, adding 1 mL ethanol, 1 mL 1,4-butanediol (internal standard) and 4 mL hexane followed by gentle mixing and centrifugation. The lower hexane phase was transferred to GC vials for analysis. Calibration standards containing known quantities of glycerol and 1,4-butanediol were used to calculate the glycerol response factor.

  • GC system: SCION 456 GC with split/splitless injector at 270 °C (split 75 mL/min)
  • Column: SCION PLOT Q, 10 m × 0.32 mm × 0.10 μm
  • Oven: 60 °C hold 12 min, ramp 20 °C/min to 120 °C, hold 1 min
  • Carrier gas: Helium at 18 psi for 12 min, then ramp to 30 psi
  • Detector: FID at 300 °C

Main Results and Discussion

Ten consecutive injections of a certified biodiesel sample yielded an average free glycerol content of 0.0425 % m/m with a relative standard deviation of 0.94 %. This performance falls well within the EN-14106 repeatability requirement of 0.03–0.08 % m/m. Chromatographic separation provided clear resolution between the glycerol and internal standard peaks.

Benefits and Practical Applications

  • Ensures compliance with biodiesel fuel standards by precise glycerol measurement
  • Supports high-throughput quality control in production environments
  • Internal standard methodology enhances robustness across sample batches

Future Trends and Opportunities

  • Adoption of automated sample preparation to increase laboratory efficiency
  • Coupling GC with mass spectrometry for improved specificity and lower detection limits
  • Implementation of real-time, online monitoring for continuous process control

Conclusion

The SCION GC-FID method effectively quantifies free glycerol in biodiesel according to EN-14106, exhibiting excellent repeatability and alignment with EN-14214 requirements. This reliable approach is well suited for routine quality assurance in biodiesel production.

References

No external literature references were provided in the source text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Performance of EPA Method 8270 using Hydrogen Carrier Gas on SCION GC MS
Performance of EPA Method 8270 using Hydrogen Carrier Gas on SCION GC-MS Application Note AN0018 INTRODUCTION United States Environmental Protection Agency (USEPA) Method 8270 is an analytical method for the detection of semi-volatile organic compounds in solid waste matrices, soils,…
Key words
scion, scionbenzo, benzopyrene, pyrenehydrogen, hydrogendichloromethane, dichloromethaneminimise, minimiseanalyser, analyserrobust, robustpropylamine, propylaminenitroso, nitrosocarrier, carrierpentachlorophenol, pentachlorophenolperylene, peryleneion, ionsource
Analysis of Greenhouse Gases by Gas Chromatography
Analysis of Greenhouse Gases by Gas Chromatography Application Note AN0012 INTRODUCTION Table 1. Analytical requirements of the four columns Nitrous Oxide (N2O), Carbon Dioxide (CO2) and Methane (CH4) are considered to be very powerful greenhouse gases. These gases reflect in…
Key words
column, columngreenhouse, greenhousescion, scionanalyser, analysergases, gasesrepeatability, repeatabilityconfiguration, configurationinstruments, instrumentsexcellent, excellentrsd, rsdperfectly, perfectlythree, threeallows, allowsmatrix, matrixtcd
Methanol in Crude Oil Analysis According to ASTM D7059-04
Methanol in Crude Oil Analysis According to ASTM D7059-04 Application Note AN069 INSTRUMENT TYPE Scion Instruments GC-based Analyser DESCRIPTION The analysis of methanol in crude oil according to ASTM D 7059: “Standard Test Method for Determination of Methanol in Crude…
Key words
methanol, methanolscion, scionploq, ploqcrude, crudeoil, oilratio, ratiomean, meaninternal, internalstandard, standarddev, devppm, ppmrepeatability, repeatabilitysubscribes, subscribesinjector, injectorstd
A True Six Channel Solution for Impurities in Ethylene
A True Six-Channel Solution for Impurities in Ethylene Application Note INTRODUCTION Ethylene is one of the highest volume chemicals produced in the world, with over 100 million metric tons produced annually. Ethylene is primarily used in the manufacture of polyethylene,…
Key words
scion, scionethylene, ethylenechannel, channelhydrocarbons, hydrocarbonssulphide, sulphidecomponents, componentsanalyser, analyserrepeatability, repeatabilitycarbon, carbonwax, waxolefinic, olefinicprincipally, principallycracked, crackedmixture, mixturesulphur
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike