A Complete Solution for the Analysis of Volatile Organic Compounds (VOCs) in Water
Applications | | SCION InstrumentsInstrumentation
Lowering detection limits of volatile organic compounds (VOCs) in drinking water is essential for regulatory compliance and public health protection. US EPA Method 524.3 requires robust analytical performance at trace levels. Modern mixed-mode GC-MS systems combining full scan and selected ion monitoring (SIM) meet these demanding sensitivity and reliability needs.
This work demonstrates a fully integrated VOC analysis solution using the Tekmar Atomx XYZ purge-and-trap concentrator coupled to the SCION 456-GC and SCION Single Quad (SQ) mass spectrometer. Key aims include automated method setup, optimization via Compound Based Scanning (CBS), and full compliance with EPA 524.3 for purgeable organics in water.
The Tekmar Atomx XYZ purge-and-trap concentrator combined with the SCION SQ mass spectrometer delivers a comprehensive, EPA-compliant solution for trace VOC analysis in water. Superior linearity, precision, and recovery confirm that all Method 524.3 criteria are exceeded in a fully automated workflow.
GC/MSD, Purge and Trap, GC/SQ
IndustriesEnvironmental
ManufacturerSCION Instruments, Teledyne LABS
Summary
Significance of the Topic
Lowering detection limits of volatile organic compounds (VOCs) in drinking water is essential for regulatory compliance and public health protection. US EPA Method 524.3 requires robust analytical performance at trace levels. Modern mixed-mode GC-MS systems combining full scan and selected ion monitoring (SIM) meet these demanding sensitivity and reliability needs.
Objectives and Study Overview
This work demonstrates a fully integrated VOC analysis solution using the Tekmar Atomx XYZ purge-and-trap concentrator coupled to the SCION 456-GC and SCION Single Quad (SQ) mass spectrometer. Key aims include automated method setup, optimization via Compound Based Scanning (CBS), and full compliance with EPA 524.3 for purgeable organics in water.
Methodology and Instrumentation
- Sample preparation: 5 mL water samples preserved and spiked for calibration.
- Calibration ranges: 0.1–40 ppb for full scan; 5–100 ppt for SIM.
- Purge-and-Trap (Atomx XYZ): purge flow 40 mL/min for 11 min; trap preheat, desorb, and bake steps at controlled temperatures (60–260 °C) and flows.
- Gas Chromatography (SCION 456-GC): SCION 624-MS column (20 m × 0.25 mm × 1.0 µm); oven program 35 °C (2 min), 10 °C/min to 170 °C, then 50 °C/min to 240 °C.
- Mass Spectrometry (SCION SQ): full scan 35–300 m/z, emission 15–20 µA, manifold 60 °C; CBS automatically schedules SIM events based on compound libraries.
Main Results and Discussion
- Spectral tuning with bromofluorobenzene exceeded all acceptance criteria using built-in target ion ratio checks.
- Linearity: correlation coefficients (R²) above 0.996 for all analytes across 0.1–40 ppb.
- Precision and MDLs: %RSD below 9%; method detection limits between 0.024 and 0.088 ppb.
- Recovery: average 99.3% with %RSD of 4.5%, satisfying EPA’s 70–150% requirement.
- Case study for 1,2-dibromoethane showed recoveries of 92–111% over 0.5–40 ppb.
Benefits and Practical Applications
- Fully automated workflow reduces manual steps and improves laboratory throughput.
- CBS streamlines complex mixed-mode method development and SIM scheduling.
- Robust system performance supports environmental monitoring, QA/QC, and compliance testing.
Future Trends and Potential Applications
- Growth of compound libraries and coupling with high-resolution MS for expanded analyte coverage.
- Advanced data analytics and machine learning for enhanced data interpretation and maintenance diagnostics.
- Portable GC-MS platforms for on-site environmental and field analyses.
- Green analytical developments focusing on solvent-free sample prep and energy efficiency.
Conclusion
The Tekmar Atomx XYZ purge-and-trap concentrator combined with the SCION SQ mass spectrometer delivers a comprehensive, EPA-compliant solution for trace VOC analysis in water. Superior linearity, precision, and recovery confirm that all Method 524.3 criteria are exceeded in a fully automated workflow.
References
- US Environmental Protection Agency. Method 524.3: Determination of Purgeable Organic Compounds in Water by Capillary Column GC/MS.
- SCION Instruments. Application Note AN0015: A Complete Solution for the Analysis of Volatile Organic Compounds (VOCs) in Water.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
EPA8260 : Analysis of Volatile Organic Compounds by GC-MS
|SCION Instruments|Applications
EPA 8260: Analysis of Volatile Organic Compounds by GC-MS AN0034 Application Note INTRODUCTION The United States Environmental Protection Agency (US EPA) was established in 1970 with the aim to protect human health and the environment. Since then environmental contamination has…
Key words
temp, tempscion, scionpurge, purgebake, bakedesorb, desorbcondenser, condenserxyz, xyzatomx, atomxbfb, bfbvariable, variabletekmar, tekmarpreheat, preheatvalue, valueconcentrator, concentratorenvironmental
Determination of Volatile Organic Compounds in Water by Purge and Trap Gas Chromatography/Mass Spectrometry
2021|Agilent Technologies|Applications
Application Note Environmental Determination of Volatile Organic Compounds in Water by Purge and Trap Gas Chromatography/Mass Spectrometry Using the Chinese Ministry of Environmental Protection method HJ 639-2012 Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd. Shanghai 200131 P. R. China…
Key words
bake, bakepurge, purgetemperature, temperaturebutylbenzene, butylbenzenesim, simscan, scandesorb, desorbsweep, sweeplod, lodloq, loqrinse, rinsechloride, chloridetime, timeflow, flowdibromofluoromethane
US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System
2019|Thermo Fisher Scientific|Applications
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1907 P+T VOC ENV US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e…
Key words
temp, tempbake, bakepurge, purgerinse, rinselpir, lpirupir, upirtert, tertsweep, sweepxyz, xyzether, etheratomx, atomxdesorb, desorbprecision, precisionmrl, mrlaccuracy
US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS
2018|Agilent Technologies|Applications
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 P+T VOC ENV US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA Method 524.3 was used to determine…
Key words
temp, tempbake, bakepurge, purgerinse, rinselpir, lpirupir, upirtert, tertsweep, sweepether, etheratomx, atomxdesorb, desorbprecision, precisionmrl, mrlaccuracy, accuracytable