GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Quality Control of Palm Oil

Applications | 2020 | MetrohmInstrumentation
NIR Spectroscopy
Industries
Food & Agriculture
Manufacturer
Metrohm

Summary

Importance of the Topic


Palm oil is one of the most widely used vegetable oils globally, with applications in food, cosmetics and biofuels. Ensuring consistent quality by monitoring parameters such as free fatty acids, iodine value, moisture, deterioration of bleachability index and carotene content is essential for product stability, nutritional value and processing efficiency.

Objectives and Study Overview


This study evaluates a rapid, cost-effective Vis-NIR spectroscopic approach using the XDS RapidLiquid Analyzer to quantify key quality parameters in crude palm oil. The aim is to replace multiple wet-chemical assays with a single, high-throughput method that requires no sample preparation or reagents.

Methodology


Palm oil samples were measured in transmission over 400–2500 nm at 60 °C using an XDS RapidLiquid Analyzer. Disposable glass vials with an 8 mm pathlength enabled reproducible, maintenance-free measurements. Vision Air Complete software managed spectral acquisition, calibration and prediction model development.

Used Instrumentation

  • XDS RapidLiquid Analyzer (Model 2.921.1410) with integrated temperature control and transmission optics
  • Disposable 8 mm pathlength vials (Metrohm 6.7402.000)
  • Vision Air 2.0 Complete software (Metrohm 6.6072.208) for data handling and chemometric modeling

Main Results and Discussion


Calibration models were built against standard reference methods: titration for free fatty acids and iodine value, Karl Fischer titration for moisture, and photometric assays for DOBI and carotene. Key performance metrics (cross-validation error and R2) are:
  • Free fatty acids: R2 = 0.835, SECV = 0.270 %
  • Iodine value: R2 = 0.911, SECV = 0.201 mg/100 g
  • Moisture: R2 = 0.638, SECV = 0.047 %
  • DOBI: R2 = 0.842, SECV = 0.19
  • Carotene: R2 = 0.677, SECV = 23.4 ppm
These results demonstrate strong correlations and acceptable precision for routine quality control applications.

Benefits and Practical Applications


The Vis-NIR method reduces analysis time from over 20 minutes to under 1 minute per sample and cuts consumable costs dramatically. At a throughput of 10 analyses per day, annual operating costs fall from approximately $42,900 (wet chemistry) to $2,063 (NIR), while eliminating chemical waste and simplifying workflow.

Future Trends and Potential Applications


Vis-NIR spectroscopy is poised for broader adoption in edible oil analysis, extending to other fats and lipid-based products. Ongoing developments include portable NIR devices for field testing, real-time process monitoring in mills and refineries, and enhanced chemometric and machine learning algorithms for improved model robustness and adulteration detection.

Conclusion


The XDS RapidLiquid Analyzer coupled with Vis-NIR spectroscopy offers a rapid, accurate and environmentally friendly solution for comprehensive quality control of palm oil. This approach streamlines laboratory workflows, lowers operational costs and supports sustainable analytical practices.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Quality Control of Palm Oil
Quality Control of Palm Oil
2020|Metrohm|Applications
AN-NIR-085 Quality Control of Palm Oil Accurate and precise determination of the iodine value Summary Determination of key quality parameters of palm oil, such as the iodine value (IV), are typically performed using time consuming and costly wet chemical methods.…
Key words
metrohm, metrohmxds, xdsnirs, nirserror, errorsimple, simpleanalyzer, analyzerrapidliquid, rapidliquidmerit, meritfigures, figuresvial, vialheater, heatervialheater, vialheaterthus, thusaccurate, accuratetempered
Quality Control of Lubricants
Quality Control of Lubricants
2020|Metrohm|Applications
AN-NIR-041 Quality Control of Lubricants Fast and chemical-free determination of the acid number, viscosity, moisture content, and color number of lubricants with NIRS Summary For lubricant analysis, determination of the Acid Number (ASTM D664), viscosity (ASTM D445), moisture content (ASTM…
Key words
metrohm, metrohmxds, xdsrapidliquid, rapidliquiderror, errormerit, meritfigures, figuresanalyzer, analyzernirs, nirscross, crossstandard, standardsimple, simpleresult, resultvalidation, validationnumber, numberlubricants
Quality Control of Diesel
Quality Control of Diesel
2020|Metrohm|Applications
AN-NIR-080 Quality Control of Diesel Fast and straightforward determination of cetane index, flash point, CFPP, D95, and viscosity with NIRS Summary The cetane index (ASTM D613), flash point (ASTM D56), cold filter plug point (CFPP) (ASTM D6371), D95 (ISO 3405),…
Key words
metrohm, metrohmerror, errormerit, meritxds, xdsfigures, figuresrapidliquid, rapidliquidcross, crossstandard, standardnirs, nirsvalidation, validationdiesel, dieselanalyzer, analyzersimple, simplevalue, valueresult
Quality Control of Isocyanates
Quality Control of Isocyanates
2020|Metrohm|Applications
AN-NIR-068 Quality Control of Isocyanates Chemical-free and fast determination of isocyanate content with NIRS Summary Determination of isocyanates (ASTM D7252) is a challenging procedure due to the reactivity of these organic species with atmospheric moisture, as well as their toxicity.…
Key words
metrohm, metrohmxds, xdsrapidliquid, rapidliquidisocyanate, isocyanateanalyzer, analyzernirs, nirssimple, simpletransmission, transmissionvialheater, vialheatertempered, temperedoptiprobe, optiprobeerror, errorisocyanates, isocyanatesmanagement, managementsolution
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike