DIOXIN: Enhanced sensitivity in GC-MS/MS technology

Presentations | 2018 | Thermo Fisher ScientificInstrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Industries
Manufacturer
Thermo Fisher Scientific

Summary

Importance of the Topic


The demand for ultra-sensitive, reliable and high-throughput analytical methods has never been greater. Modern regulatory and research laboratories require lower detection limits, robust operation over extended sequences and simplified workflows to maximize productivity. Enhanced GC-MS/MS techniques meet these challenges by delivering trace-level quantification, reduced downtime and scalable solutions for diverse matrices.

Objectives and Study Overview


This whitepaper introduces the Thermo Scientific TSQ 9000 triple quadrupole GC-MS/MS system equipped with the Advanced Electron Ionization (AEI) source and NeverVent technology. The study aims to demonstrate:
  • Attogram-range sensitivity for challenging analytes.
  • Uninterrupted routine analysis with minimal maintenance.
  • Ease of method development, from single quad to SRM workflows.
  • Scalability to accommodate growing laboratory requirements.

Methodology and Used Instrumentation


The approach integrates several innovations:
  • Advanced Electron Ionization (AEI) source with dual filaments, proprietary RF lenses and inert materials to maximize ionization efficiency and minimize contamination.
  • Rapid collision cell (EvoCell) delivering 800 SRM transitions per second for high-capacity methods.
  • NeverVent™ design enabling vent-free exchange of GC columns and ion sources.
  • TRACE 1300 GC system with Instant-Connect modules for injector and detector interchangeability.
  • Chromeleon™ CDS software featuring AutoSRM, Timed-SRM, SmartTune and eWorkflows for streamlined method development and daily operation.

Key Results and Discussion


Sensitivity tests demonstrate detection limits in the attogram range:
  • Octafluoronaphthalene IDL below 0.4 fg on-column, corresponding to ~120 ag RSD.
  • 2,3,7,8-TCDD detectable at 5 fg on-column, with an IDL RSD of ~580 ag.
  • QuEChERS pesticide extracts achieved IDLs down to 0.05 pg on-column, seven-fold more sensitive than competitor data.
  • Baby-food pesticide screen: over 60% of 211 compounds identified below 0.1 µg/kg and more than 90% below 0.5 µg/kg.
Robustness studies:
  • AEI source endured 900 injections of acetonitrile QuEChERS extracts with <20% RSD for >90% of 150 monitored pesticides.
  • PBDE repeatability across 320 fish matrix injections showed average RSD below 8% for all congeners.
  • NeverVent column and source exchanges reduced downtime by up to 98%, enabling return to analysis in under five minutes.

Benefits and Practical Applications


The TSQ 9000 AEI system offers:
  • Ultra-low detection limits for environmental, food-safety and dioxin analyses.
  • Extended uptime and minimal maintenance through inert source materials and rapid exchange capabilities.
  • High-throughput potential via compressed GC methods and high SRM speeds.
  • User-friendly software tools for seamless migration from single quadrupole to triple quadrupole methods and automated tuning.
  • Scalable configurations from entry-level to advanced NeverVent EI/CI setups to match budget and performance needs.

Future Trends and Possibilities


Ongoing developments may include:
  • Further miniaturization of ion sources to push detection into the zeptogram range.
  • Integration of machine-learning algorithms for predictive maintenance and automated method optimization.
  • Expansion of rapid collision cell capabilities to support even greater transition densities and faster chromatographic gradients.
  • Cloud-based data management and cross-platform interoperability for multi-technique laboratories.

Conclusion


The TSQ 9000 GC-MS/MS system with AEI source and NeverVent technology achieves unprecedented sensitivity, robustness and ease of use. It addresses the most demanding trace-level analyses while offering scalable, future-proof configurations and intuitive software workflows. Laboratories can confidently achieve lower detection limits, higher throughput and reduced downtime to meet evolving analytical challenges.

Used Instrumentation


  • Thermo Scientific TSQ 9000 Triple Quadrupole GC-MS/MS with Advanced Electron Ionization source
  • EvoCell Rapid Collision Cell Technology
  • Thermo Scientific TRACE 1300 Series GC with Instant-Connect modules
  • Chromeleon™ Chromatography Data System with AutoSRM, Timed-SRM and SmartTune

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Thermo Scientific TSQ 9000 Triple Quadrupole GC-MS/MS System
Thermo Scientific TSQ 9000 Triple Quadrupole GC-MS/MS System
2018|Thermo Fisher Scientific|Brochures and specifications
NOW YOU’RE Thermo Scientific TSQ 9000 Triple Quadrupole GC-MS/MS System Unstoppable GC-MS/MS Analysis Routine laboratories working in food, environmental and forensic/ toxicology analysis face a dynamic environment of changing regulatory requirements, lower detection levels, more compounds, less time, lower margins…
Key words
unstoppable, unstoppablethermo, thermoscientific, scientificextractabrite, extractabriteautosrm, autosrmyour, yourtracefinder, tracefindersim, simsource, sourceionization, ionizationsmarttune, smarttunetemplates, templatesnevervent, neverventaei, aeisrm
Thermo Scientific TSQ 9000 triple quadrupole GC-MS/MS system - PRODUCT SPECIFICATIONS
Thermo Scientific TSQ 9000 triple quadrupole GC-MS/MS system - PRODUCT SPECIFICATIONS
2018|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS TSQ 9000 triple quadrupole GC-MS/MS system Unstoppable GC-MS/MS analysis Performance benefits • Routinely detect low traces of target compounds/chemicals in difficult matrices or relieve matrix pressure on the analytical system with the new Advanced Electron Ionization (AEI) source,…
Key words
extractabrite, extractabritevpi, vpisource, sourcemass, massaei, aeisrm, srmtuning, tuningspecifications, specificationsionization, ionizationturbo, turbotracefinder, tracefindertool, toolelectron, electronsystem, systemautosrm
Thermo Scientific TSQ 9610 Triple Quadrupole GC-MS/MS System
Thermo Scientific TSQ 9610 Triple Quadrupole GC-MS/MS System
2022|Thermo Fisher Scientific|Brochures and specifications
Mass Spectrometry Stay ahead with unstoppable confidence Thermo Scientific TSQ 9610 Triple Quadrupole GC-MS/MS System Unstoppable confidence for analytical testing To confidently stay ahead, your GC-MS/MS system must deliver ultimate performance while consistently producing trusted qunatitative results. That’s the reason…
Key words
unstoppable, unstoppableaei, aeisource, sourcenevervent, neverventconfidence, confidenceextractabrite, extractabritedowntime, downtimesystem, systemsrm, srmcounts, countsthermo, thermosample, samplesim, simmaintenance, maintenancescientific
Thermo Scientific TSQ 9000 – Unstoppable Routine Analysis
Thermo Scientific TSQ 9000 – Unstoppable Routine Analysis
2018|Thermo Fisher Scientific|Presentations
Thermo Scientific TSQ 9000 – Unstoppable Routine Analysis EPRW 2018 Paul Silcock, GC GC-MS 1 The world leader in serving science TSQ 9000 GC-MS/MS Ultimate sensitivity with Advanced Electron Ionization Incredible uptime with inherent robustness and NeverVent™ technology Routine True…
Key words
aei, aeibaby, babyofn, ofnscalability, scalabilitypesticides, pesticidesmethyl, methylattogram, attogramuptime, uptimesquared, squaredbanana, bananapear, pearcarrot, carrotsante, santecycloate, cycloatebromophos
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike