Comprehensive Two-Dimensional Gas Chromatography with Orbitrap Mass Spectrometry Applied to Flavor and Fragrance Analysis
Posters | 2019 | Thermo Fisher ScientificInstrumentation
Comprehensive two-dimensional gas chromatography (GC×GC) paired with high-resolution accurate-mass Orbitrap mass spectrometry addresses key challenges in essential oil analysis. This hybrid approach enhances separation of coeluting isomers, improves trace-level sensitivity, and delivers sub-ppm mass accuracy for confident compound identification. Such capabilities are vital for quality control, authentication, and detecting adulteration in flavor and fragrance applications.
This study evaluates a reverse flow-modulated GC×GC system coupled to an Orbitrap analyzer for detailed profiling of five essential oil samples (four lavender species and one lavandin). The goals were to optimize chromatographic separation, apply high-resolution mass detection, and compare chemical compositions across different oil types.
GC×GC contour plots revealed clear separation of monoterpenes, sesquiterpenes, and other terpenoid classes across the five oil samples. Bulgarian lavender showed the highest counts of monoterpenes and sesquiterpenes, while the Abralis lavandin sample had the fewest. Co-eluted analytes undetected in one-dimensional GC were resolved in the second dimension and identified by accurate-mass deconvolution. Example cases include separation of three co-eluting peaks in Bulgarian lavender and clear resolution of cuminaldehyde from a dominant linalyl acetate peak, demonstrating superior chromatographic and spectral performance.
This work demonstrates that reversed flow-modulated GC×GC coupled with Orbitrap mass spectrometry provides robust, high-resolution separation and accurate mass detection for comprehensive essential oil analysis. The approach significantly improves confidence in identification of co-eluting and trace-level compounds, supporting rigorous quality control and authentication in the flavor and fragrance industry.
1. Zheng X, Edwards M, Cole J. Comprehensive Two-Dimensional Gas Chromatography with Orbitrap Mass Spectrometry Applied to Flavor and Fragrance Analysis. Thermo Fisher Scientific; 2019.
GCxGC, GC/MSD, GC/MS/MS, GC/HRMS, GC/Orbitrap
IndustriesFood & Agriculture
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Comprehensive two-dimensional gas chromatography (GC×GC) paired with high-resolution accurate-mass Orbitrap mass spectrometry addresses key challenges in essential oil analysis. This hybrid approach enhances separation of coeluting isomers, improves trace-level sensitivity, and delivers sub-ppm mass accuracy for confident compound identification. Such capabilities are vital for quality control, authentication, and detecting adulteration in flavor and fragrance applications.
Study Objectives and Overview
This study evaluates a reverse flow-modulated GC×GC system coupled to an Orbitrap analyzer for detailed profiling of five essential oil samples (four lavender species and one lavandin). The goals were to optimize chromatographic separation, apply high-resolution mass detection, and compare chemical compositions across different oil types.
Methodology and Instrumentation
- Sample Preparation: Essential oils diluted 1:100 in hexane.
- GC×GC Configuration: Thermo Scientific TRACE 1310 GC with a TG-5silMS primary column (20 m × 0.18 mm × 0.18 µm) and TG-17silMS secondary column (4 m × 0.25 mm × 0.25 µm). An INSIGHT reversed flow modulator (SepSolve Analytical) performed heart-cutting and reinjection steps to enhance peak capacity and reduce peak tailing.
- Mass Spectrometry: Q Exactive GC Orbitrap, electron ionization at 70 eV, transfer line and source at 250 °C, mass range m/z 50–600, full-scan acquisition, and lock-mass calibration at m/z 207.03235, 281.05114, and 355.06990.
- Data Processing: Thermo Scientific TraceFinder 4.1 and SepSolve ChromSpace for peak detection, deconvolution, contour plotting, and quantitative analysis.
Main Results and Discussion
GC×GC contour plots revealed clear separation of monoterpenes, sesquiterpenes, and other terpenoid classes across the five oil samples. Bulgarian lavender showed the highest counts of monoterpenes and sesquiterpenes, while the Abralis lavandin sample had the fewest. Co-eluted analytes undetected in one-dimensional GC were resolved in the second dimension and identified by accurate-mass deconvolution. Example cases include separation of three co-eluting peaks in Bulgarian lavender and clear resolution of cuminaldehyde from a dominant linalyl acetate peak, demonstrating superior chromatographic and spectral performance.
Benefits and Practical Applications
- Sub-ppm mass accuracy enables reliable elemental formula determination and confident compound identification.
- Enhanced sensitivity supports trace-level detection of flavor and fragrance constituents, including unknowns.
- Efficient separation of isomeric compounds and structurally similar analytes reduces ambiguity in complex mixtures.
- Comprehensive aromatic profiling aids quality control, authentication, and adulteration screening in essential oil production.
Future Trends and Potential Applications
- Integration of chemometric and machine-learning tools for automated classification and anomaly detection in essential oil datasets.
- Expansion of GC×GC-Orbitrap applications to other complex matrices such as botanical extracts, food contaminants, and environmental pollutants.
- Development of real-time screening workflows and high-throughput platforms for industrial quality assurance.
- Enhanced three-dimensional data visualization and template-based comparison for rapid sample differentiation.
Conclusion
This work demonstrates that reversed flow-modulated GC×GC coupled with Orbitrap mass spectrometry provides robust, high-resolution separation and accurate mass detection for comprehensive essential oil analysis. The approach significantly improves confidence in identification of co-eluting and trace-level compounds, supporting rigorous quality control and authentication in the flavor and fragrance industry.
References
1. Zheng X, Edwards M, Cole J. Comprehensive Two-Dimensional Gas Chromatography with Orbitrap Mass Spectrometry Applied to Flavor and Fragrance Analysis. Thermo Fisher Scientific; 2019.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Coupling Comprehensive Two-Dimensional Gas Chromatography with an Orbitrap MS for Enhanced Separation and Identification
2019|Thermo Fisher Scientific|Posters
Coupling Comprehensive Two-Dimensional Gas Chromatography with an Orbitrap MS for Enhanced Separation and Identification Xin Zheng1, Matt Edwards2, Jason Cole1, 1Thermo Fisher Scientific, Austin, Texas; 2SepSolve Analytical, UK ABSTRACT Two-dimensional (2D) gas chromatography (GC × GC) is a comprehensive technique…
Key words
hram, hrammass, massmodulator, modulatorocimene, ocimeneformula, formulaprimary, primarylimonene, limoneneelucidation, elucidationspectrometry, spectrometrygas, gaspopular, popularreinjects, reinjectsisomers, isomerscolumn, columnhas
Using flow-modulated GC×GC technology coupled with GC-Orbitrap mass spectrometry for the profiling of automotive diesel
2022|Thermo Fisher Scientific|Posters
Using flow-modulated GC×GC technology coupled with GC-Orbitrap mass spectrometry for the profiling of automotive diesel Jason Cole1, Xin Xeng1, Dominic Roberts2 and David Lee2 1 Thermo Fisher Scientific, Austin, Texas. 2Thermo Fisher Scientific, Hemel Hempstead, United Kingdom. ABSTRACT Table 1.…
Key words
chromspace, chromspaceorbitrap, orbitrapcertainty, certaintymodulated, modulatedexploris, explorisgroups, groupsdiesel, dieselhram, hramstraightforward, straightforwardcan, canbuild, buildpina, pinadata, datastencils, stencilsenabling
Comprehensive analysis of automotive diesel using flow-modulated GC×GC technology coupled with GC-MS
2021|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 000050 Comprehensive analysis of automotive diesel using flow-modulated GC×GC technology coupled with GC-MS Authors: David Lee1, Cristian Cojocariu1, Aaron Parker2, and Ryan Sutherill2 Thermo Fisher Scientific, UK 2 SepSolve Analytical, UK 1 Keywords: Two-dimensional gas chromatography, flow modulation,…
Key words
axis, axisdiesel, dieselfid, fidexploris, explorisjets, jetsorbitrap, orbitrapmodulated, modulatedresolving, resolvingdimensional, dimensionalcan, canflow, flowline, linecomprehensive, comprehensivecompounds, compoundscertainty
SepSolve ChromSpace software
||Brochures and specifications
ChromSpace ® A powerful and versatile software platform for multi-dimensional GC ChromSpace The GC×GC software you’ve been waiting for Unlock the power of GC×GC with effortless data exploration in ChromSpace. ••••••••••••••••••••••••••••••••••• Designed using feedback from experts in industry and academia,…
Key words
chromspace, chromspacestencils, stencilscolour, coloursepsolve, sepsolveoverlooked, overlookedsimple, simplepalette, palettescripting, scriptingpeaks, peaksfiles, filesdeconvolution, deconvolutiondata, datadynamically, dynamicallyflexible, flexibletof