PCB and Dioxin Analysis Automated Sample Clean-up

 

Similar PDF

Toggle
LCTech DEXTech Plus
2017|LCTech|Brochures and specifications
Fast and Flexible Sample Preparation in Dioxin and PCB Analysis through Automation 1 Sample Preparation Done by Specialists The automated DEXTech Plus sample preparation system for dioxin and PCB analysis cleans quickly and flexibly all kinds of extracts: • •…
Key words
pcb, pcbortho, orthondl, ndllctech, lctechflorisil, florisilpcdd, pcddgovernmental, governmentalmono, monoautomation, automationsensor, sensorlaboratory, laboratorydioxin, dioxingreatest, greatestcolumn, columndextech
Flexible Automated Sample Clean-up of PCDD/Fs and PCBs Dioxin 2019, Kyoto Maximilian Baumann, LCTech GmbH LCTech GmbH History and Development Automated QuEChERS method for residue analysis in food Fully automated sample and feed clean-up of 16 samples in one sequence…
Key words
dioxin, dioxinmethode, methodeautomated, automatedpcb, pcblctech, lctechclean, cleanpure, puresample, samplepcbs, pcbsdextech, dextechclick, clickgmbh, gmbhhardening, hardeningjust, justdioxins
APPLICATION NOTE | AN0028 Automated Clean-up of Various Brominated Compounds: a Breast Milk Example APPLICATION NOTE | www.LCTech-online.com As of: November 2019, Version: 1.1 APPLICATION NOTE | AN0028 Content 1. Introduction ................................................................................................................................................. 3 2. Method Development .............................................................................................................................. 4 2.1 Reagents…
Key words
hxcdf, hxcdfrecovery, recoverypbde, pbdebrominated, brominatedhxbdd, hxbddbreastmilk, breastmilkpecdf, pecdfpcb, pcbhpcdf, hpcdfclean, cleanortho, orthopcdd, pcddretardants, retardantsalumina, aluminadioxins
APPLICATION NOTE | AN0034 D-EVA – Automated EVAporation of PCDD/F Extracts to 100 - 200 μL PCB Extracts to 300 – 500 μL Thomas Kerkemeier (LCTech GmbH) Dr. Uwe Aulwurm (LCTech GmbH) APPLICATION NOTE | www.LCTech-online.com As of: November 2019,…
Key words
eva, evambar, mbarevaporation, evaporationpicograde, picogradelctech, lctechcentrifuge, centrifugepcdd, pcdddryness, drynessrinsing, rinsingvacuum, vacuumvials, vialscongeners, congenersdown, downnitrogen, nitrogenpolychlorinated