Agilent G3835AA MassHunter Mass Profiler Professional Software - Familiarization Guide
Manuals | 2012 | Agilent TechnologiesInstrumentation
Mass spectrometry–based differential analysis is essential for understanding complex biological and environmental systems. Agilent MassProfiler Professional (MPP) leverages high-resolution MS data to detect meaningful differences across sample groups, enabling robust biomarker discovery in metabolomics, proteomics, natural products, food and beverage testing, and environmental monitoring.
This guide uses a Malaria LC/MS ESI+ pH7 demonstration project to introduce the core MPP workflow. Key objectives are:
This tutorial relies on Agilent software platforms integrated for advanced MS data analysis:
The workflow consists of:
Parameter selection (eg, 0.1% RT window, 5 ppm mass window, minimum abundance 5000 counts) is guided by data quality and instrument resolution.
Using the Malaria dataset, alignment yielded 474 features common to all eight samples and 1,283 single occurrences. Filter flags removed low-reproducibility “one-hit wonders.” Significance analysis (p < 0.05, fold change ≥ 2) focused the list on statistically relevant markers. Compound identification integrated seamlessly to annotate features for downstream biological interpretation.
MPP offers:
Emerging directions include machine learning–driven classification, cloud-based collaboration and data sharing, expanded multi-omics integration, and enrichment of pathway databases for deeper biological insights.
This familiarization guide provides a structured approach to leverage Agilent MPP for reproducible, high-throughput MS differential analysis. By following the stepwise workflow, users can efficiently generate, filter, and identify candidate biomarkers for diverse applications.
Software
IndustriesManufacturerAgilent Technologies
Summary
Importance of the topic
Mass spectrometry–based differential analysis is essential for understanding complex biological and environmental systems. Agilent MassProfiler Professional (MPP) leverages high-resolution MS data to detect meaningful differences across sample groups, enabling robust biomarker discovery in metabolomics, proteomics, natural products, food and beverage testing, and environmental monitoring.
Objectives and study overview
This guide uses a Malaria LC/MS ESI+ pH7 demonstration project to introduce the core MPP workflow. Key objectives are:
- Create and configure a new MPP project and experiment
- Import, organize, and preprocess sample data
- Perform initial statistical analysis and fold change filtering
- Identify compounds with MassHunter ID Browser
- Archive and share results
Instrumentation used
This tutorial relies on Agilent software platforms integrated for advanced MS data analysis:
- MassHunter Mass Profiler Professional (G3835AA)
- MassHunter Workstation
- Spectrum Mill
- ChemStation
Methodology and instrumentation
The workflow consists of:
- MS Experiment Creation Wizard – grouping, filtering (abundance, mass, retention time), alignment, normalization, baselining
- Significance Testing and Fold Change Wizard – statistical filtering by p-value and fold change
- MassHunter ID Browser – compound annotation by formula, mass, and retention time
Parameter selection (eg, 0.1% RT window, 5 ppm mass window, minimum abundance 5000 counts) is guided by data quality and instrument resolution.
Key results and discussion
Using the Malaria dataset, alignment yielded 474 features common to all eight samples and 1,283 single occurrences. Filter flags removed low-reproducibility “one-hit wonders.” Significance analysis (p < 0.05, fold change ≥ 2) focused the list on statistically relevant markers. Compound identification integrated seamlessly to annotate features for downstream biological interpretation.
Benefits and practical applications
MPP offers:
- A streamlined end-to-end MS data analysis pipeline
- Integrated compound annotation and pathway analysis for metabolomics and proteomics
- Automated class prediction for unknown samples in QA/QC and research contexts
Future trends and opportunities
Emerging directions include machine learning–driven classification, cloud-based collaboration and data sharing, expanded multi-omics integration, and enrichment of pathway databases for deeper biological insights.
Conclusion
This familiarization guide provides a structured approach to leverage Agilent MPP for reproducible, high-throughput MS differential analysis. By following the stepwise workflow, users can efficiently generate, filter, and identify candidate biomarkers for diverse applications.
Reference
- Keseler et al, Nucleic Acids Research 39:D583–590 (2011)
- Caspi et al, Nucleic Acids Research 40:D742–753 (2012)
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent G3835AA MassHunter Mass Profiler Professional Software - Overview and Data Import Quick Start Guide
2012|Agilent Technologies|Manuals
Agilent G3835AA MassHunter Mass Profiler Professional Software Overview and Data Import Quick Start Guide What is Agilent Mass Profiler Professional? Agilent Mass Profiler Professional (MPP) is a powerful visualization and statistical analysis solution designed for the chemometric analysis of mass…
Key words
profiler, profilerimport, importprofessional, professionalproject, projectexperiment, experimentyou, youclick, clickquick, quickstart, startguide, guidedata, dataoverview, overviewcomments, commentsmalaria, malariasteps
Agilent G3835AA MassHunter Mass Profiler Professional Software - Application Guide
2015|Agilent Technologies|Manuals
Agilent G3835AA MassHunter Mass Profiler Professional Software Application Guide 1. Prepare for your Experiment 5 2. Find the Features in your Data 7 3. Import and Organize your Data 10 4. Create your Initial Analysis 29 5. Save your project…
Key words
profiler, profilerprofessional, professionalexperiment, experimentguide, guideclick, clickyour, yourcomments, commentssteps, stepsinstructions, instructionsyou, youmass, massdetailed, detailedidentified, identifiedgrouping, groupingapplication
Agilent G3835AA MassHunter Mass Profiler Professional Software - Quick Start Guide
2017|Agilent Technologies|Manuals
Agilent G3835AA MassHunter Mass Profiler Professional Software Quick Start Guide For Research Use Only. Not for use in diagnostic procedures. Getting Started 6 User Interface 11 Basic Tasks 16 Advanced Tasks 25 Acknowledgment and Citations 26 What is Agilent Mass…
Key words
project, projectmpp, mppprofiler, profilerguide, guideprofessional, professionalexperiment, experimentstart, startquick, quickdialog, dialoglicense, licensemalaria, malariayou, youexisting, existingmass, massbox
MassHunter Profinder Software - Quick Start Guide
2017|Agilent Technologies|Manuals
MassHunter Profinder Software Quick Start Guide For Research Use Only. Not for use in diagnostic procedures. Getting Started 11 User Interface 12 Basic Profinder Workflow 22 Add sample files to your project 24 Align chromatograms 28 Edit and run your…
Key words
profinder, profinderfeature, featureisotopologue, isotopologueguide, guideextraction, extractionquick, quickstart, startyour, yourclick, clickbatch, batchworkflow, workflowproject, projectrecursive, recursiveyou, youfile