ASTM D5441 - Impurities in MTBE

Applications |  | QuadrexInstrumentation
GC, GC columns, Consumables
Industries
Energy & Chemicals
Manufacturer
Quadrex

Summary

Importance of the Topic


MTBE is a widely used gasoline oxygenate and octane booster. Monitoring trace impurities is critical for fuel performance, regulatory compliance and environmental safety. Robust analytical methods ensure accurate quantification of alcohols, hydrocarbons and ethers present as contaminants.

Objectives and Overview of the Study


The aim of this application note is to demonstrate the separation and detection of common impurities in methyl tert-butyl ether (MTBE) using gas chromatography with flame ionization detection, following the ASTM D5441 protocol. The study outlines optimized conditions enabling baseline resolution of target compounds.

Methodology


  • Column: Dimethylpolysiloxane PHAT Phase™ 20M (007-1-20HS-6.0F), 0.18 mm I.D., 6 μm film thickness
  • Temperature program: 40 °C (3 min hold), ramp 5 °C/min to 100 °C, then 12 °C/min to 210 °C
  • Carrier gas: Helium, 12 psi constant flow
  • Injector temperature: 225 °C
  • Detector: Flame ionization detector, 300 °C

Used Instrumentation


  • Gas chromatograph equipped with FID
  • PHAT Phase™ 20M capillary column (007-1-20HS-6.0F)
  • Helium supply for carrier gas

Key Results and Discussion


The optimized method achieved clear separation of eleven impurities in MTBE samples:
  • Methanol
  • 2-Methylbutane
  • Pentane
  • Cis-2-pentene
  • Trans-2-pentene
  • 2-Methyl-2-butene
  • MTBE
  • t-Butyl ethyl ether
  • t-Amyl methyl ether
  • 2,2,4-Trimethyl-1-pentene
  • Cis/trans-2,2′,4,6,6′-pentamethyl-3-heptene
Baseline separation was achieved with sharp peak shapes and good sensitivity, demonstrating compliance with ASTM requirements.

Benefits and Practical Applications


  • Reliable quantitation of MTBE impurities for quality control
  • Compliance with industry standard (ASTM D5441)
  • Efficient analysis suitable for high-throughput labs

Future Trends and Opportunities


  • Integration with mass spectrometry for enhanced identification
  • Development of shorter, more inert columns for faster analyses
  • Green chromatography approaches reducing solvent and energy usage

Conclusion


The presented GC-FID method provides a robust and efficient solution for analyzing impurities in MTBE, meeting regulatory standards and supporting routine quality control in petrochemical laboratories.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
C1 to C10 Hydrocarbons
C1 to C10 Hydrocarbons
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical C1 to C10 Hydrocarbons COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier: 007-1, Dimethylpolysiloxane PHAT Phase™ 20M. x 0.18mm I.D. x 6.0μm film 007-1-20HS-6.0F 35° (3 min. hold) (2°/min.) 48° - (6°/min.) - 210°C, hold. 200°C…
Key words
petrochemical, petrochemicalhydrocarbons
C1 to C5 Hydrocarbons
C1 to C5 Hydrocarbons
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical C1 to C5 Hydrocarbons COLUMN: Cat. No.: Temperature: Injector: Detector: 007-1, Bonded Dimethylpolysiloxane PHAT Phase™ 30M. x 0.32mm I.D. x 10.0μm film 007-1-30W-10.0F 35° (3 min hold) (2°/min.) 45° - (6°/min.) - 100°C 150°C 250°C,…
Key words
dimethylpolysiloxane, dimethylpolysiloxanepetrochemical, petrochemicalhydrocarbons
Analysis of Methyl-t-Butyl Ether (MTBE) and related impurities per ASTM test method D5441 using Zebron™ ZB-DHA-PONA Gas Chromatography Column
TN-2083 APPLICATIONS Analysis of Methyl-t-Butyl Ether (MTBE) and related impurities per ASTM test method D5441 using Zebron™ ZB-DHA-PONA Gas Chromatography Column Dr. Ramkumar Dhandapani*, Zeshan Aqeel, and Tim Nelson Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Ramkumar Dhandapani,…
Key words
pona, ponadha, dhamtbe, mtbezebron, zebronreproducing, reproducinglove, lovetrouble, troubleboiling, boilingmin, minhaving, havingbutanol, butanolcolumn, columntert, tertshape, shapeimpurities
Analysis of Methyl-t-Butyl Ether (MTBE) and related impurities per ASTM test method D5441 using Zebron™ ZB-DHA-PONA Gas Chromatography Column
TN-2083 APPLICATIONS Analysis of Methyl-t-Butyl Ether (MTBE) and related impurities per ASTM test method D5441 using Zebron™ ZB-DHA-PONA Gas Chromatography Column Dr. Ramkumar Dhandapani*, Zeshan Aqeel, and Tim Nelson Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Ramkumar Dhandapani,…
Key words
pona, ponadha, dhamtbe, mtbezebron, zebronreproducing, reproducinglove, lovetrouble, troubleboiling, boilingmin, minhaving, havingbutanol, butanolcolumn, columnshape, shapetert, tertimpurities
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike