Support for 21 CFR Part 11 Compliance: Agilent MassHunter for GC/MS
Technical notes | 2016 | Agilent TechnologiesInstrumentation
Compliance with 21 CFR Part 11 and its international analogs is critical in pharmaceutical and regulated laboratories to ensure electronic records and signatures meet ALCOA principles (Attributable, Legible, Contemporaneous, Original, Accurate). Implementing robust technical and procedural controls fosters data integrity, facilitates audits, and supports regulatory approval of GC/MS analyses.
This whitepaper guides users of Agilent MassHunter for GC/MS systems on achieving 21 CFR Part 11 compliance. It outlines the system’s role as a closed solution for data acquisition and processing, describes user and supplier responsibilities, and maps each regulatory requirement to technical controls within MassHunter and OpenLAB ECM, supplemented by procedural controls such as SOPs and internal audits.
The compliant analytical platform comprises:
The system combines embedded software features with organizational procedures to satisfy Part 11 requirements:
Appendix 1 demonstrates that MassHunter for GC/MS, when used with OpenLAB ECM, satisfies every relevant Part 11 criterion with “yes” for technical controls. Noteworthy features include byte-order checksums for record validity, comprehensive audit-trail coverage across methods and data, and robust eSignature manifestations. Remaining gaps (e.g., “why” field in quantitative-analysis audit trails) can be addressed procedurally.
Implementing this integrated solution enables laboratories to:
Emerging developments may include:
Agilent MassHunter for GC/MS, combined with OpenLAB ECM, offers comprehensive technical controls to address 21 CFR Part 11 electronic‐records and signatures requirements. To achieve full compliance, user organizations must implement supporting SOPs, training, and internal audit programs. The solution reduces manual effort and enhances data integrity, preparing laboratories for rigorous regulatory scrutiny.
Software
IndustriesManufacturerAgilent Technologies
Summary
Importance of Topic
Compliance with 21 CFR Part 11 and its international analogs is critical in pharmaceutical and regulated laboratories to ensure electronic records and signatures meet ALCOA principles (Attributable, Legible, Contemporaneous, Original, Accurate). Implementing robust technical and procedural controls fosters data integrity, facilitates audits, and supports regulatory approval of GC/MS analyses.
Aims and Overview of Whitepaper
This whitepaper guides users of Agilent MassHunter for GC/MS systems on achieving 21 CFR Part 11 compliance. It outlines the system’s role as a closed solution for data acquisition and processing, describes user and supplier responsibilities, and maps each regulatory requirement to technical controls within MassHunter and OpenLAB ECM, supplemented by procedural controls such as SOPs and internal audits.
Used Instrumentation
The compliant analytical platform comprises:
- Agilent MassHunter GC/MS Acquisition software
- Agilent MassHunter Quantitative Analysis (compliance toolset)
- Single-quadrupole and triple-quadrupole GC/MS instruments
- Agilent OpenLAB Enterprise Content Manager (ECM)
Methodology and Technical Controls
The system combines embedded software features with organizational procedures to satisfy Part 11 requirements:
- Validation – Supplier provides software validation documentation; users perform installation-specific qualification.
- Accurate Copies – Records (methods, sequences, raw and result data, audit trails, eSignatures) are viewable and printable in human-readable and electronic forms.
- Secure Retention & Retrieval – Automatic storage of data and metadata in ECM; checksum verification ensures file integrity.
- Access Control – User authentication via Windows or ECM credentials; role-based permissions restrict functions (e.g., method editing).
- Audit Trails – Secure, time-stamped logs document who, what, when, where, and optionally why changes occur; audit entries are immutable and linked to records.
- Operational Checks – Workflow sequencing enforced by permissions; instrument identifiers (serial number, IP) recorded with data.
- Electronic Signatures – Optional eSignature module enforces unique user ID, password, signature meaning, full name, date/time, and links signatures irreversibly to records.
- Password & ID Controls – Unique credentials, password aging, lock-out settings managed via Windows or ECM policies.
Key Results and Discussion
Appendix 1 demonstrates that MassHunter for GC/MS, when used with OpenLAB ECM, satisfies every relevant Part 11 criterion with “yes” for technical controls. Noteworthy features include byte-order checksums for record validity, comprehensive audit-trail coverage across methods and data, and robust eSignature manifestations. Remaining gaps (e.g., “why” field in quantitative-analysis audit trails) can be addressed procedurally.
Benefits and Practical Applications
Implementing this integrated solution enables laboratories to:
- Streamline regulatory compliance and facilitate FDA/EU inspections.
- Reduce paper-based recordkeeping and transcription errors.
- Maintain end-to-end data integrity and traceability.
- Accelerate method development, review, and approval workflows.
Future Trends and Potential Applications
Emerging developments may include:
- Cloud-hosted compliance platforms for global data sharing.
- Blockchain-based audit trails for enhanced immutability.
- Machine-learning tools for automated anomaly detection in audit logs.
- Deeper integration with laboratory information management systems (LIMS) and digital quality-management systems.
Conclusion
Agilent MassHunter for GC/MS, combined with OpenLAB ECM, offers comprehensive technical controls to address 21 CFR Part 11 electronic‐records and signatures requirements. To achieve full compliance, user organizations must implement supporting SOPs, training, and internal audit programs. The solution reduces manual effort and enhances data integrity, preparing laboratories for rigorous regulatory scrutiny.
References
- R. A. Botha and J. H. P. Eloff. Separation of duties for access control enforcement in workflow environments. IBM Systems Journal, 40(3), 666–682 (2001).
- U.S. Food and Drug Administration. Title 21 CFR Part 11: Electronic Records; Electronic Signatures, accessed November 2015.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Support for Title 21 CFR Part 11 and Annex 11 compliance: Agilent MassHunter GC/MS Software Products
2025|Agilent Technologies|Others
White Paper Support for Title 21 CFR Part 11 and Annex 11 compliance: Agilent MassHunter GC/MS Software Products Valid for MassHunter GC/MS Data Acquisition Version 13.0 and Data Analysis Version 12.1 Update 2 Overview U.S. Food and Drug Administration (US…
Key words
yes, yesmasshunter, masshunterresponsibility, responsibilityelectronic, electronicrecords, recordsorganization, organizationuser, useraudit, auditsatisfied, satisfiedpassword, passwordrequirement, requirementsignatures, signaturescomments, commentsregulations, regulationsothers
OpenLAB ECM and Microsoft Excel: Managing Spreadsheets in a Regulated Environment
2017|Agilent Technologies|Technical notes
Technical Note OpenLAB ECM OpenLAB ECM and Microsoft Excel: Managing Spreadsheets in a Regulated Environment Introduction Microsoft Excel is powerful spreadsheet software used by labs for calculations, analytics, and tracking to monitor product quality and improve efficiencies. Due to its…
Key words
yes, yesecm, ecmexcel, excelmicrosoft, microsoftopenlab, openlabelectronic, electronicresponsibility, responsibilityaudit, audittrail, trailsignature, signaturecomments, commentsrecords, recordsuser, userrequirement, requirementsignatures
Support for Title 21 CFR Part 11 and Annex 11 Compliance: Agilent OpenLab Server and OpenLab ECM XT
2024|Agilent Technologies|Technical notes
White Paper Support for Title 21 CFR Part 11 and Annex 11 Compliance: Agilent OpenLab Server and OpenLab ECM XT Valid for OpenLab Server and OpenLab ECM XT version 2.8 Overview US FDA Part 11 in Title 21 of the…
Key words
yes, yesecm, ecmopenlab, openlabserver, serverresponsibility, responsibilityorganization, organizationelectronic, electronicuser, usersignature, signaturesatisfied, satisfiedrecords, recordssignatures, signaturesregulations, regulationsothers, otherscomments
Support for Title 21 CFR Part 11 and Annex 11 Compliance: Agilent MicroLab Pharma
2020|Agilent Technologies|Technical notes
White Paper Support for Title 21 CFR Part 11 and Annex 11 Compliance: Agilent MicroLab Pharma Overview US FDA Part 11 in Title 21 of the Code of Federal Regulations (CFR), and its EU analog, Eudralex Chapter 4, Annex 11,…
Key words
yes, yeselectronic, electronicuser, userrecords, recordspassword, passwordresponsibility, responsibilityscm, scmmicrolab, microlabsignatures, signaturesaudit, auditorganization, organizationrecommendation, recommendationsignature, signatureusers, usersothers