Ultra-Low Level Pesticide Residues Analysis using a New State-of-the-Art Enhanced Sensitivity GC-MS/MS System
Others | | Thermo Fisher ScientificInstrumentation
Monitoring pesticide residues in baby foods is critical to ensure compliance with regulatory limits and to protect vulnerable populations from toxicological risks. Lower maximum residue levels have been established by EU regulations to address compounds with unacceptable hazards. High throughput and rapid turnaround during analysis are essential due to sample perishability and the large volume of testing required by official control laboratories.
The combined QuEChERS dispersive SPE GC MS MS workflow with advanced ionization and automated data processing delivers reliable ultra low level pesticide residue analysis in baby food. It meets stringent SANTE and EU regulatory requirements while offering rapid throughput high sensitivity and robust long term performance suitable for routine laboratories.
GC/MSD, GC/MS/MS, GC/QQQ
IndustriesFood & Agriculture
ManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Monitoring pesticide residues in baby foods is critical to ensure compliance with regulatory limits and to protect vulnerable populations from toxicological risks. Lower maximum residue levels have been established by EU regulations to address compounds with unacceptable hazards. High throughput and rapid turnaround during analysis are essential due to sample perishability and the large volume of testing required by official control laboratories.
Objectives and Study Overview
- Evaluate a fully integrated workflow combining QuEChERS sample preparation with dispersive SPE clean up and enhanced sensitivity GC MS MS detection
- Demonstrate compliance with SANTE quality control and validation criteria for over 200 pesticides in processed baby food
- Establish limits of detection identification linearity precision and robustness that meet or exceed EU MRL requirements
Methodology
- Sample matrices: ready to eat apple – pear – banana and carrot – potato baby foods spiked at multiple levels using citrate buffered QuEChERS
- Clean up: HyperSep dispersive SPE with PSA and GCB to remove co extractives and pigments
- Injection: direct analysis of acetonitrile extracts avoids solvent exchange and minimizes analyte loss
Instrumentation Used
- TRACE 1310 GC system with PTV injection on TG 5SilMS column and SafeGuard integrated guard
- TSQ 9000 triple quadrupole GC MS MS with advanced electron ionization source offering high ion yield and robustness
- TriPlus RSH autosampler with user interchangeable Instant Connect injector modules
- Chromeleon 7.2 CDS software for instrument control data processing reporting and compliance with 21 CFR Part 11
Main Results and Discussion
- All 210 pesticides detected at spiking levels down to 1 µg kg and many compounds quantified below 0.1 µg kg
- Limits of identification below 0.5 µg kg for 90 percent and below 0.1 µg kg for 60 percent of analytes well under EU MRLs
- Excellent linearity over five orders of magnitude with R2 values above 0.99 for most pesticides
- Recovery 70 to 120 percent with RSD below 20 percent meeting SANTE criteria
- Robustness demonstrated by over 900 sequential injections with stable ion flux minimal downtime and only liner replacement
Benefits and Practical Applications
- High sensitivity reduces need for extensive concentration steps minimizing matrix effects
- Fast analysis turnaround under 48 hours supports official control and QA QC laboratories
- Automated workflow enhances productivity data integrity and method reproducibility
Future Trends and Opportunities
- Development of higher sensitivity sources and advanced chromatographic phases for emerging contaminants
- Integration with machine learning for automated method optimization and suspect screening
- Expansion of SRM transition libraries to include metabolites and degradation products
- Adoption of field portable mass spectrometers for onsite rapid screening
Conclusion
The combined QuEChERS dispersive SPE GC MS MS workflow with advanced ionization and automated data processing delivers reliable ultra low level pesticide residue analysis in baby food. It meets stringent SANTE and EU regulatory requirements while offering rapid throughput high sensitivity and robust long term performance suitable for routine laboratories.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Ultra low level quantification of pesticides in baby foods using an advanced triple quadrupole GC-MS/MS system
2018|Thermo Fisher Scientific|Applications
APPLICATION NOTE 10586 Ultra low level quantification of pesticides in baby foods using an advanced triple quadrupole GC-MS/MS system Authors Richard Law, Aaron Lamb, Paul Silcock, and Cristian Cojocariu Thermo Fisher Scientific, Runcorn, UK Goal The aim of the study…
Key words
loq, loqrsd, rsdmean, meanrecovery, recoveryprecision, precisionpear, pearcarrot, carrotbanana, bananapotato, potatomethyl, methylbromophos, bromophosapple, appleethyl, ethylppb, ppblinearity
Thermo Scientific TSQ 9000 – Unstoppable Routine Analysis
2018|Thermo Fisher Scientific|Presentations
Thermo Scientific TSQ 9000 – Unstoppable Routine Analysis EPRW 2018 Paul Silcock, GC GC-MS 1 The world leader in serving science TSQ 9000 GC-MS/MS Ultimate sensitivity with Advanced Electron Ionization Incredible uptime with inherent robustness and NeverVent™ technology Routine True…
Key words
aei, aeibaby, babyofn, ofnscalability, scalabilitypesticides, pesticidesmethyl, methylattogram, attogramuptime, uptimesquared, squaredpear, pearbanana, bananacarrot, carrotsante, santecycloate, cycloatebromophos
Ultra-Low Level Quantification of Pesticides in Baby Foods using an Advanced Triple Quadrupole GC-MS/MS
2018|Thermo Fisher Scientific|Posters
Ultra-Low Level Quantification of Pesticides in Baby Foods using an Advanced Triple Quadrupole GC-MS/MS Richard Law1, Aaron Lamb1, Paul Silcock1, Tim Anderson2 and Cristian Cojocariu1, 1Thermo Fisher Scientific, Runcorn, UK, 2Thermo Fisher Scientific, Austin, TX, USA ABSTRACT Purpose: The maximum…
Key words
rsd, rsdmean, meanprecision, precisionrecovery, recoverymethyl, methylbaby, babybromfenvinphos, bromfenvinphossquared, squaredallidochlor, allidochlornonachlor, nonachlorquechers, quecherstolylfluanid, tolylfluanidhypersep, hypersepsulprofos, sulprofoschlorfenapyr
Ultra-Low Level Quantification of Pesticides in Baby Foods using an Advanced Triple Quadrupole GC-MS/MS
2019|Thermo Fisher Scientific|Posters
Ultra-Low Level Quantification of Pesticides in Baby Foods using an Advanced Triple Quadrupole GC-MS/MS Adam Ladak2, Richard Law1, Aaron Lamb1, Paul Silcock1, Tim Anderson2 and Cristian Cojocariu1; 1Thermo Fisher Scientific, Runcorn, UK, 2Thermo Fisher Scientific, Austin, TX, USA Compound linearity…
Key words
rsd, rsdmean, meanprecision, precisionrecovery, recoveryethyl, ethylbortran, bortranfipronil, fipronilethylan, ethylantetrahydrophthalimide, tetrahydrophthalimideperthane, perthanechlorpyrifos, chlorpyrifossquared, squaredisazophos, isazophosthpi, thpimethyl