Organochlorine Pesticides Analysis in Water by GC/ECD - Consumable workflow ordering guide

Brochures and specifications | 2021 | Agilent TechnologiesInstrumentation
GC columns, Consumables
Industries
Environmental
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Persistent organochlorine pesticides pose long-term risks to water quality and human health due to their stability and bioaccumulation. Reliable detection at trace levels ensures compliance with environmental regulations and protects ecosystems and drinking water supplies.

Objectives and Study Overview


This work presents a comprehensive workflow for identifying and quantifying organochlorine pesticides in water using gas chromatography with dual‐electron capture detection (GC/ECD). It evaluates compliance with EPA Method 8081B and related protocols while demonstrating improvements in sensitivity, inertness, and throughput.

Methodology and Instrumentation


  • Sample Preparation and Standards: Water samples spiked with organochlorine analytes and surrogates; calibration following EPA SW-846 guidelines.
  • Chromatographic Configuration: Dual-column confirmation using Agilent J&W DB-CLP1 and DB-CLP2, plus optional VF-5 and VF-1701 columns for broad method coverage.
  • Key Consumables for Inert Flow Path: Ultra Inert inlet liners, gold‐coated seals, UltiMetal Plus ferrules, Flexible Metal ferrules, self-tightening column nuts, and rigorously tested Ultra Inert columns to minimize active site interactions.
  • GC/ECD Conditions: Fast 7.5-minute separation for targeted QC analytes; extended 30-minute run for full suite of 47 compounds; EPA 508.1 herbicide/pesticide method; rapid 11-minute method using the Agilent Intuvo 9000 with Flow Chips and Guard Chip protection.

Main Results and Discussion


  • System Inertness: Endrin and DDT breakdown remained below EPA specifications (individual <15%, combined <30%) over 200+ injections using the inert flow path.
  • Separation Performance: Fast method achieved baseline resolution of key chlorinated pesticides in under 7.5 minutes; extended method separated 47 analytes in 30 minutes.
  • Retention Time Stability: Retention time locking on DB-CLP1 columns yielded <0.008% RSD across 20 pesticide compounds, simplifying method maintenance and calibration.
  • Throughput Enhancement: Intuvo 9000 GC system reduced extended-method runtime to ~11 minutes without compromising resolution, increasing sample throughput.

Benefits and Practical Applications


  • Enhanced Sensitivity and Accuracy: Inert flow path components prevent analyte adsorption and degradation, improving peak shapes and quantitative reliability.
  • Operational Efficiency: Durable consumables and extended maintenance intervals reduce instrument downtime and labor costs.
  • Versatility: Single column set supports multiple EPA GC/ECD methods (8081B, 8082, 508.1, 608.3), streamlining workflows across laboratories.
  • Regulatory Compliance: Robust performance ensures adherence to EPA and CLP quality control criteria for environmental monitoring.

Future Trends and Opportunities


Advances in column materials and flow path design will further enhance inertness and reduce bleed. Integration with automated sample preparation (SPME and SPME Arrow) and high-throughput GC systems will support rapid screening of emerging contaminants. Machine-learning-driven method optimization may tailor conditions for new analyte classes and complex matrices.

Conclusion


Implementing an inert GC/ECD flow path with optimized column sets delivers reliable, high-throughput analysis of organochlorine pesticides in water. Adherence to EPA protocols, combined with advanced consumables and modern GC platforms, ensures accurate quantitation, regulatory compliance, and laboratory efficiency.

Reference


  • Endrin and DDT Breakdown Evaluation Using an Agilent Inert Flow Path Solution; 5991-1862EN.
  • Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns; 5991-0615EN.
  • Dual Column 8081 Pesticide Analysis by GC/ECD with Agilent J&W VF-5 and VF-1701 Columns; SI-00924EN.
  • Retention Time Locking of Organochlorine Pesticides on an Agilent 8860 GC System; 5994-0551EN.
  • Organochlorine Pesticide Analysis Using an Agilent Intuvo 9000 Dual ECD GC System; 5991-9000EN.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent J&W GC Columns For Environmental Applications
Agilent J&W GC Columns For Environmental Applications
2012|Agilent Technologies|Brochures and specifications
Agilent J&W GC Columns For Environmental Applications MEASURE TRACE-LEVEL CONTAMINANTS AND MEET REGULATORY REQUIREMENTS WITH CONFIDENCE Reliably and efficiently analyze increasingly small quantities of active solutes Every day, you are on the front lines in the battle to safeguard our…
Key words
identification, identificationbenzo, benzobhc, bhcpeak, peakendrin, endrinagilent, agilentpesticides, pesticidescolumns, columnsendosulfan, endosulfanmin, minheptachlor, heptachlorxylene, xyleneinert, inertcolumn, columnultra
New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories
New Application Specific Columns for Semi-volatile and ECD Methods Lead the Way to Higher Productivity in Environmental Laboratories Ken Lynam CSD Application Chemist Presentation Outline • DB-UI 8270D columns for semi-volatile analysis – Testing procedures – Example chromatograms – Addition…
Key words
bhc, bhcmethyl, methylester, esterendrin, endrinheptachlor, heptachlortranslation, translationendosulfan, endosulfanchlordane, chlordaneenhancing, enhancingpackaging, packagingclp, clpliner, linerproductivity, productivityepoxide, epoxidesurrogate
New Application Specific Columns
New Application Specific Columns
2013|Agilent Technologies|Presentations
New Application Specific Columns Simon Jones GC columns Application Engineer What Columns are New? DB-CLP1 DB-CLP2 Environmental DB-UI 8270D DB-Select 624 UI 467 US Pharmacopeia What are the Benefits? Address specific issues with certain methods Response Tailing factor Resolution Named…
Key words
min, minbhc, bhcendrin, endrinheptachlor, heptachlorchlordane, chlordaneendosulfan, endosulfanpermethrin, permethrinpesticides, pesticidesepoxide, epoxidemethyl, methylaldrin, aldrinnonachlor, nonachlorbenzo, benzodecachlorobiphenyl, decachlorobiphenyltrans
New Application Specific Columns
New Application Specific Columns
2014|Agilent Technologies|Presentations
New Application Specific Columns Simon Jones GC columns Application Engineer What Columns are New? DB-CLP1 DB-CLP2 Environmental DB-UI 8270D DB-Select 624 UI 467 DB-Sulfur SCD PLOT-PT US Pharmacopeia What are the Benefits? Address specific issues with certain methods Response Tailing…
Key words
plot, plotmin, minscd, scdporabond, porabondbhc, bhcporaplot, poraplotendrin, endrinheptachlor, heptachlorchlordane, chlordaneendosulfan, endosulfancolumns, columnsalumina, aluminasulfur, sulfurmethyl, methylcolumn
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike