Intuvo 9000 GC - Firmware Bulletin - Revision A.02.2.2.4
Manuals | 2021 | Agilent TechnologiesInstrumentation
Firmware control is essential to maintain GC reliability, ensure compatibility with data systems and third party chromatography software, and support advanced instrument features in modern analytical laboratories. It underpins interoperability, performance optimization and regulatory compliance for routine QA/QC and research environments.
This bulletin documents the firmware support information for Agilent Intuvo 9000 GC series. It covers compatibility guidelines, validation notes, supported CDS drivers from Agilent and third parties (Waters Empower, Thermo Chromeleon), detailed change history across firmware revisions and the firmware update procedure.
Agilent Intuvo 9000 GC equipped with firmware update utility version 2.3.3.0 or later
Current firmware 2.2.2.4 introduces critical fixes for detector baseline stability and column compensation downloads. Key enhancements from recent versions include:
The Agilent Intuvo 9000 GC firmware bulletin serves as a definitive guide for maintaining up-to-date instrument software. Regular firmware updates deliver stability improvements, new user-centric features and ensure seamless integration within diverse chromatographic workflows.
Agilent Technologies Firmware Bulletin D0007856 Revision A.02.2.2.4 Issued January 11, 2021
GC
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Firmware control is essential to maintain GC reliability, ensure compatibility with data systems and third party chromatography software, and support advanced instrument features in modern analytical laboratories. It underpins interoperability, performance optimization and regulatory compliance for routine QA/QC and research environments.
Objectives and Overview of the Bulletin
This bulletin documents the firmware support information for Agilent Intuvo 9000 GC series. It covers compatibility guidelines, validation notes, supported CDS drivers from Agilent and third parties (Waters Empower, Thermo Chromeleon), detailed change history across firmware revisions and the firmware update procedure.
Methodology and Instrumentation
Agilent Intuvo 9000 GC equipped with firmware update utility version 2.3.3.0 or later
- Select the Intuvo 9000 GC product in the firmware update tool
- Enter the instrument IP address
- Upload the firmware package file (9000_FW_X.X.X.tgz.gpg)
- Automated download and firmware installation, followed by instrument reboot
Results and Discussion
Current firmware 2.2.2.4 introduces critical fixes for detector baseline stability and column compensation downloads. Key enhancements from recent versions include:
- Quiet Mode to reduce fan noise during cooling and limit maximum zone duty cycles
- Peak Evaluation feature enabling automated monitoring of up to ten chromatographic peak attributes
- Mobile-optimized browser interface offering run status, remaining run time and 20-minute static detection plots
- Expanded acquisition data rates and improved split ratio specifications to align with competitive systems
- Enhanced security by allowing 4 to 8 digit PIN enforcement for WebUI access
Benefits and Practical Applications
- Reduced acoustic footprint enhances user comfort and safety in high-throughput laboratories
- Remote monitoring capabilities lower downtime by alerting users to run status and diagnostic events off-site
- Peak Evaluation supports inline quality checks and rapid identification of method drift or sample anomalies
- Firmware alignment with major CDS platforms ensures seamless integration and validated operation in regulated environments
Future Trends and Opportunities
- Integration of artificial intelligence for predictive maintenance and autonomous parameter optimization
- Advanced mobile and cloud-based dashboards providing real-time alerts and historical performance analytics
- Broader third party driver support and direct cloud connectivity for laboratory information management systems
- Intelligent firmware capable of self-calibration, emission of advanced diagnostics and dynamic method adjustments
Conclusion
The Agilent Intuvo 9000 GC firmware bulletin serves as a definitive guide for maintaining up-to-date instrument software. Regular firmware updates deliver stability improvements, new user-centric features and ensure seamless integration within diverse chromatographic workflows.
Reference
Agilent Technologies Firmware Bulletin D0007856 Revision A.02.2.2.4 Issued January 11, 2021
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 8890 GC - Firmware Bulletin - Revision 2.2.2.4
2021|Agilent Technologies|Manuals
Agilent 8890GC Firmware Bulletin Revision 2.2.2.4 Internal and External use Revision: 1.00, Issued: January 11th, 2021 Agile Document Number: D0007855 DE number: 44237.4805787037 © Agilent Technologies, Inc. 2021 Page ____ of ____ About this Document This document provides the firmware…
Key words
browser, browserlui, luitouchscreen, touchscreendsa, dsaevaluation, evaluationsequence, sequencetitle, titleissue, issuefirmware, firmwareblank, blankadded, addedsupport, supportrun, runsignal, signalconfigured
Agilent 8860 GC - Firmware Bulletin - Revision 2.2.2.4
2021|Agilent Technologies|Manuals
Agilent 8860 GC Firmware Bulletin Revision 2.2.2.4 Internal and External use About this Document This document provides the firmware changes used for the following GC System • 8860 GC (G2790A) Revision: 2.00, Issued: January 11, 2021 Agile Document Number: D0007856…
Key words
express, expressbrowser, browserinterface, interfacefirmware, firmwaretitle, titleissue, issuesequence, sequencewhen, whenversion, versionsupport, supportdoes, doesreport, reportals, alssignal, signalincorrect
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2
2025|Agilent Technologies|Manuals
Agilent ICF Support Layer for Waters CDS Release Notes – Revision 4.2 Notices Manual Part Number Warranty D0128450 The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further,…
Key words
supported, supportedicf, icfagilent, agilentfirmware, firmwaredriver, driverwicf, wicfmodules, modulesempower, empowersupport, supporttower, towerinstrument, instrumentinficfsl, inficfslwaters, watersabort, abortissues
Agilent Intuvo 9000 Gas Chromatograph - Site Preparation Checklist
2020|Agilent Technologies|Manuals
Agilent CrossLab Start-Up Services Agilent Intuvo 9000 Gas Chromatograph Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start-Up is focused on helping customers shorten the time it takes to start realizing the full value of…
Key words
hydrogen, hydrogensupplies, suppliesnitrogen, nitrogengas, gaspsi, psiamps, ampssupply, supplysite, sitecarrier, carrierplumbing, plumbinghelium, heliumtermination, terminationcustomer, customerspecial, specialnotes