SPME Arrow
Technical notes | | ShimadzuInstrumentation
Solid-Phase Microextraction (SPME) Arrow technology represents an evolution of classical SPME fibers, offering greater sorbent volume, improved mechanical robustness and enhanced sampling efficiency. These features make SPME Arrows particularly valuable for trace analysis of volatile and semi-volatile compounds in complex matrices such as environmental samples, food and beverage testing, forensic investigations and quality control applications.
This technical note provides comprehensive guidance for the effective use, conditioning and maintenance of SPME Arrows. It outlines the available product variants, recommended operational parameters, conditioning and cleaning procedures, and best practices to ensure consistent performance and prolonged device life.
SPME Arrows feature an external diameter of 1.1 mm or 1.5 mm and a fixed sorbent length of 20 mm. Various sorbent phases are offered, including PDMS, acrylate, carbon wide range/PDMS, DVB/PDMS and mixed phases. Key instrumentation and consumables include:
Available SPME Arrow configurations are identified by outer diameter, sorbent type, phase thickness and color code. Recommended maximum operating temperatures range from 280 °C (acrylate) to 300 °C (PDMS, carbon-based phases). Conditioning involves an initial preconditioning step at 20 °C above the planned analysis temperature, followed by periodic thermal desorption in inert gas. Typical conditioning and preconditioning times vary between 15 min and 120 min, with recommended rinsing in methanol, ethanol or iso-propanol to remove contaminants. Product life spans depend on sample matrix and contact with liquid phases; headspace sampling often permits hundreds of extractions, while direct immersion in complex matrices may limit use to tens of runs.
SPME Arrows deliver higher sorbent capacity and mechanical durability compared to traditional fibers, resulting in:
Ongoing advances may include novel sorbent coatings tailored for specific analyte classes, further miniaturization of Arrow dimensions, integration with automated sampling platforms and enhanced coupling with high-resolution mass spectrometry. Expanding applications are expected in environmental monitoring, food safety, metabolomics and pharmaceutical QA/QC.
By adhering to defined conditioning, cleaning and operational protocols, users can maximize the performance and longevity of SPME Arrows. Proper selection of sorbent phase and operating conditions ensures reliable, high-quality data across diverse analytical workflows.
SPME, Consumables
IndustriesManufacturerShimadzu
Summary
Importance of the Topic
Solid-Phase Microextraction (SPME) Arrow technology represents an evolution of classical SPME fibers, offering greater sorbent volume, improved mechanical robustness and enhanced sampling efficiency. These features make SPME Arrows particularly valuable for trace analysis of volatile and semi-volatile compounds in complex matrices such as environmental samples, food and beverage testing, forensic investigations and quality control applications.
Objectives and Overview
This technical note provides comprehensive guidance for the effective use, conditioning and maintenance of SPME Arrows. It outlines the available product variants, recommended operational parameters, conditioning and cleaning procedures, and best practices to ensure consistent performance and prolonged device life.
Methodology and Instrumentation
SPME Arrows feature an external diameter of 1.1 mm or 1.5 mm and a fixed sorbent length of 20 mm. Various sorbent phases are offered, including PDMS, acrylate, carbon wide range/PDMS, DVB/PDMS and mixed phases. Key instrumentation and consumables include:
- AOC-6000 Arrow Conditioning Module
- Agitator and Heatex Stirrer accessories
- Wide-bore GC injection ports and matching liners for 1.1 mm or 1.5 mm Arrows
Main Results and Discussion
Available SPME Arrow configurations are identified by outer diameter, sorbent type, phase thickness and color code. Recommended maximum operating temperatures range from 280 °C (acrylate) to 300 °C (PDMS, carbon-based phases). Conditioning involves an initial preconditioning step at 20 °C above the planned analysis temperature, followed by periodic thermal desorption in inert gas. Typical conditioning and preconditioning times vary between 15 min and 120 min, with recommended rinsing in methanol, ethanol or iso-propanol to remove contaminants. Product life spans depend on sample matrix and contact with liquid phases; headspace sampling often permits hundreds of extractions, while direct immersion in complex matrices may limit use to tens of runs.
Benefits and Practical Applications
SPME Arrows deliver higher sorbent capacity and mechanical durability compared to traditional fibers, resulting in:
- Improved sensitivity and reproducibility for trace analysis
- Reduced risk of fiber breakage and contamination
- Streamlined method development through a selection of sorbent chemistries
- Flexibility for both headspace and direct immersion extractions
Future Trends and Opportunities
Ongoing advances may include novel sorbent coatings tailored for specific analyte classes, further miniaturization of Arrow dimensions, integration with automated sampling platforms and enhanced coupling with high-resolution mass spectrometry. Expanding applications are expected in environmental monitoring, food safety, metabolomics and pharmaceutical QA/QC.
Conclusion
By adhering to defined conditioning, cleaning and operational protocols, users can maximize the performance and longevity of SPME Arrows. Proper selection of sorbent phase and operating conditions ensures reliable, high-quality data across diverse analytical workflows.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Smart SPME Arrow
|Shimadzu|Technical notes
ERAD-0001-9032 Smart SPME Arrow Note This data sheet contains important notes for the operator. It is highly recommended for operators to become familiarized with the product prior to use. • When using with AOC-6000 Plus, Arrow Conditioning PDMS - 100…
Key words
spme, spmesmart, smartarrow, arrowpdms, pdmsetoh, etohiprop, ipropmeoh, meohdvb, dvbplydimethylsiloxane, plydimethylsiloxaneconditioning, conditioningcarbon, carbongrey, greyaliphatic, aliphaticrinsing, rinsingpreconditioning
Smart SPME Fiber
|Shimadzu|Technical notes
ERAD-0001-9036 Smart SPME Fiber Note This data sheet contains important notes for the operator. It is highly recommended for operators to become familiarized with the product prior to use. • When using with AOC-6000 Plus, Conditioning Module and Agitator are…
Key words
fiber, fiberiprop, iproppdms, pdmsetoh, etohmeoh, meohconditioning, conditioningplydimethylsiloxane, plydimethylsiloxanedvb, dvbsmart, smartspme, spmealiphatic, aliphaticrinsing, rinsingpreconditioning, preconditioningcarbon, carbongrey
SPME Fiber
|Shimadzu|Technical notes
ERAD-0001-9038 SPME Fiber Note This data sheet contains important notes for the operator. It is highly recommended for operators to become familiarized with the product prior to use. • When using with AOC-6000, Conditioning Modle and Agitator are essential. •…
Key words
fiber, fiberiprop, iproppdms, pdmsetoh, etohmeoh, meohconditioning, conditioningplydimethylsiloxane, plydimethylsiloxanespme, spmedvb, dvbaliphatic, aliphaticrinsing, rinsingpreconditioning, preconditioningcarbon, carbongrey, greytemperature
General Information for Agilent Smart SPME Arrows
2021|Agilent Technologies|Technical notes
General Information for Agilent Smart SPME Arrows Using Agilent Smart SPME Arrows Please refer to Table 3 for additional consumables for use with SPME Arrows. – Set the PAL gas input pressure to 2 bar when using Conditioning Module(s). This…
Key words
spme, spmearrow, arrowsmart, smartarrows, arrowspdms, pdmsconditioning, conditioningetoh, etohmeoh, meohdvb, dvbrecommended, recommendedipa, ipapolyacrylate, polyacrylatecarbon, carbonpenetration, penetrationgray