Importance of the Topic
The legacy organochlorine pesticides are persistent and toxic environmental contaminants that accumulate in ecosystems and pose health risks. Monitoring their presence in water, soil and food is critical for regulatory compliance and public safety. GC coupled with Electron Capture Detection provides a cost effective and sensitive approach for trace level analysis of these chlorinated compounds.Objectives and Study Overview
This study aims to implement and evaluate a GC ECD method following US EPA Method 8081 for quantitation of twenty organochlorine pesticides in solid and liquid matrices. The focus is on achieving reliable separation, sensitivity and reproducibility using a Thermo Scientific TRACE 1310 GC system with TriPlus RSH autosampler and Instant Connect modules.Methodology
A slight modification of US EPA 8081 is applied: use of a 30 m TG-5MS capillary column with 0.25 micrometer film thickness and optimized oven temperature program. Samples are extracted and purified according to EPA guidelines and injected in splitless mode with 1 microliter volume. Calibration standards range from 0.1 to 100 ppb.Instrumentation
- TRACE 1310 Gas Chromatograph
- TriPlus RSH Autosampler in liquid injection splitless mode
- Instant Connect Split-Splitless Injector at 250 C
- Instant Connect Electron Capture Detector at 320 C with 15 mL/min nitrogen makeup gas
- Dionex Chromeleon 7.2 software for data acquisition and processing
Main Results and Discussion
The method achieved excellent separation with resolution scores of 1.0 for alpha chlordane versus endosulfan I and 0.9 for DDT versus endosulfan sulfate. Calibration curves were linear with coefficients of determination above 0.998 for all analytes. Limits of detection ranged from 0.013 to 0.103 ppb, demonstrating sub-ppb sensitivity. Retention time repeatability was below 0.05 percent RSD and peak area repeatability below 5 percent RSD, confirming high precision.Benefits and Practical Applications
This GC ECD approach offers a cost effective alternative to mass spectrometry for routine monitoring of chlorinated pesticide residues in environmental and food laboratories. The high sensitivity and selectivity for chlorinated analytes ensure compliance with regulatory limits while maintaining operational simplicity and throughput.Future Trends and Opportunities
Advances in column technology and detector electronics may further improve resolution and lower detection limits. Integration with automated sample preparation and data analytics could streamline large scale monitoring programs. Expanding the method to emerging chlorinated compounds and complex matrices will enhance its applicability in environmental surveillance and food safety assessment.Conclusion
The developed GC ECD method following US EPA 8081 demonstrates robust performance for quantifying organochlorine pesticides at trace levels. Excellent linearity, sensitivity and reproducibility confirm its suitability as a reliable and economical solution for environmental and food analysis laboratories.References
No external literature references were provided in the source document.Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Organochlorine pesticide analysis using an Agilent Intuvo 9000 Dual ECD GC system
2018|Agilent Technologies|Applications
Organochlorine pesticide analysis using an Agilent Intuvo 9000 Dual ECD GC system Technology advantage: GC Flow Chip modularity for dual column analysis Introduction Organochlorine pesticides are often measured following protocols from the Contract Laboratory Program (CLP) of the United States…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordanehelptachlor, helptachlororganochlorine, organochlorinemethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinheptachlor, heptachlorketone, ketonepesticides, pesticidessulfate
Bulletin 841C Chlorinated Pesticides Analysis by Capillary GC: Alternative Approaches We manufacture and test SPB-608 capillary columns specifically for analyses of chlorinated pesticides. 30m x 0.25mm ID columns can be used in capillary GC systems; 15m x 0.53mm ID columns…
Key words
bhc, bhcendosulfan, endosulfanendrin, endrinheptachlor, heptachlorpesticides, pesticidesepoxide, epoxidedieldrin, dieldrinaldrin, aldrinaldehyde, aldehydesupelco, supelcosulfate, sulfateextraction, extractionchlordane, chlordaneenvi, envimethoxychlor
Multiple Tools for Demanding Needs: Trace Detection of Organochlorine Pesticides by Agilent 7000E and 7010C GC/MS/MS
2024|Agilent Technologies|Posters
Poster Reprint ASMS 2024 Poster number WP 263 Multiple Tools for Demanding Needs: Trace Detection of Organochlorine Pesticides by Agilent 7000E and 7010C GC/MS/MS Erinn O’Neill1, Alexis Willey1, and Anastasia Andrianova1 1Agilent Technologies, Inc., Wilmington, Delaware, USA Introduction Experimental Organochlorine…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlordieldrin, dieldrinmethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidealdrin, aldrinketone, ketonetrans, transcis, cissulfate, sulfaterse
GC Monitoring of Chlorinated Pesticides in Hazardous Waste Sites
1999|Merck|Applications
TheReporter Reprinted from Volume 14, No. 5, 1995 T295045 © 1999 Sigma-Aldrich Co. For more information, or current prices, contact your nearest Supelco subsidiary listed below. To obtain further contact information, visit our website (www.sigma-aldrich.com), see the Supelco catalog, or…
Key words
endrin, endrinbhc, bhcendosulfan, endosulfansupelco, supelcochlordane, chlordaneheptachlor, heptachlorketone, ketonepesticides, pesticidesfigure, figurealdehyde, aldehydeepoxide, epoxidetetrachloro, tetrachloroinertness, inertnessclp, clpdecachlorobiphenyl