Multi-Fold Reduction in Drugs of Abuse Detection Limits Using Full Scan GCMS with a High Efficiency Source
Posters | 2016 | Agilent TechnologiesInstrumentation
Forensic toxicology screening demands full spectrum identification of a broad range of drugs of abuse in biological matrices. Conventional full-scan GC-MS is often limited by sensitivity, requiring derivatization or SIM methods. The implementation of a high efficiency ion source enhances ion production, lowers detection limits, and preserves spectral integrity for reliable library matching.
This work evaluates the Agilent 5977B GC-MSD equipped with a High Efficiency Source (HES) coupled to deconvolution reporting software (DRS/AMDIS) and a forensic toxicology library. The goal is to compare detection limits and spectral quality against a standard extractor source for underivatized drugs in human serum.
Sample Preparation:
GC-MS Conditions:
The HES delivered up to twenty times more ion signal compared to the extractor source, translating into significantly improved detection levels for multiple drugs of abuse:
Spectral integrity remained high, yielding classical spectra searchable in NIST. The system differentiated cocaine from pseudococaine and distinguished cocaine stereoisomers based on characteristic ion ratios. At concentrations above 5 ng/mL, cocaine returned NIST match factors ≥900.
Advances may include integration of high-resolution MS for increased selectivity, expanded libraries for novel psychoactive substances, and automated AI-driven deconvolution. Portable GC-MS platforms with high efficiency sources could enable on-site forensic screening. Further improvements in source design may push detection limits even lower.
The Agilent 5977B GC-MSD equipped with the High Efficiency Source and DRS/AMDIS software markedly improves sensitivity for underivatized drug screening in serum. It enables full-scan detection limits approaching SIM methods, preserves spectral integrity for accurate library searches, and supports isomer differentiation.
GC/MSD, GC/SQ
IndustriesForensics
ManufacturerAgilent Technologies
Summary
Importance of Topic
Forensic toxicology screening demands full spectrum identification of a broad range of drugs of abuse in biological matrices. Conventional full-scan GC-MS is often limited by sensitivity, requiring derivatization or SIM methods. The implementation of a high efficiency ion source enhances ion production, lowers detection limits, and preserves spectral integrity for reliable library matching.
Objectives and Study Overview
This work evaluates the Agilent 5977B GC-MSD equipped with a High Efficiency Source (HES) coupled to deconvolution reporting software (DRS/AMDIS) and a forensic toxicology library. The goal is to compare detection limits and spectral quality against a standard extractor source for underivatized drugs in human serum.
Methodology and Instrumentation
Sample Preparation:
- Negative human serum (2 mL) extracted via Bond Elut Certify general drug screen method M2721
- Evaporation and reconstitution in 0.1 mL methanol, spiked with mixed drug standards (10–1000 ng/mL)
- Injection of 1 µL extract
GC-MS Conditions:
- Agilent 5977B GC-MS with HES (magnet removed) and standard extractor source
- Column: 15 m × 0.25 mm id × 0.25 µm DB-5ms Ultra Inert with backflush via Purged Ultimate Union
- Oven program: 90 °C to 325 °C over 15 min; pulsed splitless inlet at 280 °C; source at 300 °C; quadrupole at 180 °C
- Data processing via DRS/AMDIS, Minimum Match Factor 75, custom and NIST library searches
Main Results and Discussion
The HES delivered up to twenty times more ion signal compared to the extractor source, translating into significantly improved detection levels for multiple drugs of abuse:
- Hydrocodone identified at 5 ng/mL (versus 25 ng/mL)
- Nicotine detected at 2.5 ng/mL with high match scores
- MDMA, MDEA, phencyclidine, methadone and others screened below 10 ng/mL
Spectral integrity remained high, yielding classical spectra searchable in NIST. The system differentiated cocaine from pseudococaine and distinguished cocaine stereoisomers based on characteristic ion ratios. At concentrations above 5 ng/mL, cocaine returned NIST match factors ≥900.
Benefits and Practical Applications
- Full-scan sensitivity approaching that of SIM methods without derivatization
- Broad drug screening capability in routine forensic toxicology workflows
- Robust deconvolution and reliable library matching for confident compound identification
Future Trends and Possibilities
Advances may include integration of high-resolution MS for increased selectivity, expanded libraries for novel psychoactive substances, and automated AI-driven deconvolution. Portable GC-MS platforms with high efficiency sources could enable on-site forensic screening. Further improvements in source design may push detection limits even lower.
Conclusion
The Agilent 5977B GC-MSD equipped with the High Efficiency Source and DRS/AMDIS software markedly improves sensitivity for underivatized drug screening in serum. It enables full-scan detection limits approaching SIM methods, preserves spectral integrity for accurate library searches, and supports isomer differentiation.
References
- Anon Agilent Bond Elut Certify and Certify II Methods Manual Agilent Technologies Inc Publication number 5991-4939EN 2014
- NIST Standard Reference Database 1A NIST/EPA/NIH Mass Spectral Library NIST 14 and Mass Spectral Search Program Version 2.2 Users Guide
- Schlesinger HL Topics in the chemistry of cocaine B Narcotics 1985 1 63-78 United Nations Office on Drugs and Crime
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Screen More Drugs with the Agilent GC/MS Toxicology Analyzer with a High Efficiency Source
2017|Agilent Technologies|Applications
Screen More Drugs with the Agilent GC/MS Toxicology Analyzer with a High Efficiency Source Application Note Forensic Toxicology Authors Introduction Melissa Churley and Broad-range screening for drugs in biological samples requires full-spectrum identification confirmation for an unlimited number of targets,…
Key words
hes, hescocaine, cocaineamdis, amdisscreen, screenfentanyl, fentanylisomer, isomerscreening, screeningtoxicology, toxicologyscore, scorecuadra, cuadraforensic, forensicserum, serumrodriguez, rodriguezfeyerherm, feyerhermluis
Significant Improvement in GCMS Screening of Pesticides by Use of a High Efficiency Ion Source and Spectral Deconvolution
2016|Agilent Technologies|Posters
Significant Improvement in GCMS Screening of Pesticides by Use of a High Efficiency Ion Source and Spectral Deconvolution Melissa Churley1 and Bruce Quimby2 Introduction Routine pesticide residue analysis in environmental and food samples requires low-level detection with confident identification, which…
Key words
deconvolution, deconvolutionspectrum, spectrumsource, sourcelibrary, libraryefficiency, efficiencyspectral, spectralbeam, beamtargets, targetsgcms, gcmsautotuned, autotunedmainlib, mainlibexcerpt, excerptelectron, electronpesticides, pesticidestranslates
Significant Improvement in GCMS Screening of Pesticides by Use of a High Efficiency Source and Spectral Deconvolution
2016|Agilent Technologies|Posters
Significant Improvement in GCMS Screening of Pesticides by Use of a High Efficiency Source and Spectral Deconvolution Melissa Churley1 and Bruce Quimby2 1Agilent Technologies Inc., 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA 2Agilent Classical spectra with excellent library…
Key words
deconvolution, deconvolutionspectrum, spectrumlibrary, librarypesticides, pesticidessource, sourcespectral, spectralbeam, beamtargets, targetsefficiency, efficiencygcms, gcmsmainlib, mainlibelectron, electrondrs, drsscreening, screeningmagnet
Identify More Pesticides Faster Using the Agilent High-Efficiency Source
2015|Agilent Technologies|Applications
Identify More Pesticides Faster Using the Agilent High-Efficiency Source The Agilent Pesticide DRS Screening GC/MSD Analyzer Application Note Food Testing & Agriculture Authors Melissa Churley and Bruce Quimby Agilent Technologies, Inc. The Agilent Pesticide DRS Screening GC/MSD Analyzer, based on…
Key words
drs, drshes, hespesticides, pesticidesdisruptors, disruptorsreporting, reportingpesticide, pesticideanalyzer, analyzercharge, chargemore, moreexr, exrscreening, screeningagilent, agilenttargets, targetsdeconvolution, deconvolutionmsd