Round-the-clock, online and cryogen-free monitoring of VOC hydrocarbons in ambient air using GC-MS
Applications | 2017 | Thermo Fisher ScientificInstrumentation
Urban and industrial emissions of volatile organic compounds (VOCs) contribute to ground-level ozone and smog formation, posing health and environmental risks. Regulatory agencies in Europe and the United States mandate continuous, round-the-clock monitoring of key ozone precursors at urban sites to assess emission trends and support air quality management.
This study describes the evaluation and validation of a fully cryogen-free thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) system for online, unattended monitoring of 59 VOC precursors specified under the USEPA Photochemical Assessment Monitoring Stations (PAMS) program. The goal was to demonstrate compliance with detection limits below 0.5 ppb, hourly sampling, and robust field operation.
Ambient air was drawn continuously through a cooled, sorbent-packed focusing trap using the UNITY-xr Air Server-xr at 25 mL/min. A Kori-xr dehydration unit removed water without loss of polar analytes. Trapped VOCs were thermally desorbed and transferred via a TraceGOLD Bond Q column to a TRACE 1310 GC coupled to an ISQ LT mass spectrometer operated in full-scan mode. Breakthrough tests for highly volatile species (e.g. acetylene) confirmed linear retention up to 0.5 L sampling volume. Retention times remained stable across 80% relative humidity, and multi-point calibrations provided correlation coefficients above 0.99, relative standard deviations below 3%, and method detection limits typically under 0.3 ppb.
The narrow-bore focusing trap and custom sorbent mix enabled quantitative retention of C2–C11 VOCs under splitless conditions. Kori-xr effectively removed water, preventing retention shifts and ensuring reliable mass spectral identification. GC-MS detection resolved co-eluting species via extracted ion chromatograms, improving quantitation accuracy. Modular GC components and a field-serviceable MS source minimized downtime and simplified maintenance in remote monitoring stations.
This cryogen-free TD-GC-MS platform meets stringent PAMS requirements for sensitivity and selectivity, consolidating all target VOCs in a single sampling cycle. Automated mass spectral matching enables detection of known and unknown compounds, while modular design supports rapid field repairs.
Integration with advanced data management software will facilitate remote monitoring and real-time reporting. Expanding analyte lists and coupling with atmospheric modeling could improve source apportionment and regulatory compliance across urban and industrial environments.
The validated TD-GC-MS system delivers reliable, unattended, cryogen-free monitoring of EPA PAMS VOC precursors with high sensitivity, robust field maintenance, and comprehensive data quality, offering a modern alternative to legacy Auto-GC platforms.
GC/MSD, Thermal desorption, GC/SQ
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific, Markes
Summary
Significance of the topic
Urban and industrial emissions of volatile organic compounds (VOCs) contribute to ground-level ozone and smog formation, posing health and environmental risks. Regulatory agencies in Europe and the United States mandate continuous, round-the-clock monitoring of key ozone precursors at urban sites to assess emission trends and support air quality management.
Objectives and study overview
This study describes the evaluation and validation of a fully cryogen-free thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) system for online, unattended monitoring of 59 VOC precursors specified under the USEPA Photochemical Assessment Monitoring Stations (PAMS) program. The goal was to demonstrate compliance with detection limits below 0.5 ppb, hourly sampling, and robust field operation.
Methodology
Ambient air was drawn continuously through a cooled, sorbent-packed focusing trap using the UNITY-xr Air Server-xr at 25 mL/min. A Kori-xr dehydration unit removed water without loss of polar analytes. Trapped VOCs were thermally desorbed and transferred via a TraceGOLD Bond Q column to a TRACE 1310 GC coupled to an ISQ LT mass spectrometer operated in full-scan mode. Breakthrough tests for highly volatile species (e.g. acetylene) confirmed linear retention up to 0.5 L sampling volume. Retention times remained stable across 80% relative humidity, and multi-point calibrations provided correlation coefficients above 0.99, relative standard deviations below 3%, and method detection limits typically under 0.3 ppb.
Used instrumentation
- UNITY-xr Air Server-xr sample concentrator
- Kori-xr dehydration trap
- TRACE 1310 gas chromatograph with Instant Connect inlet
- Thermo Scientific ISQ LT mass spectrometer
- TraceGOLD Bond Q analytical column
Main results and discussion
The narrow-bore focusing trap and custom sorbent mix enabled quantitative retention of C2–C11 VOCs under splitless conditions. Kori-xr effectively removed water, preventing retention shifts and ensuring reliable mass spectral identification. GC-MS detection resolved co-eluting species via extracted ion chromatograms, improving quantitation accuracy. Modular GC components and a field-serviceable MS source minimized downtime and simplified maintenance in remote monitoring stations.
Benefits and practical applications
This cryogen-free TD-GC-MS platform meets stringent PAMS requirements for sensitivity and selectivity, consolidating all target VOCs in a single sampling cycle. Automated mass spectral matching enables detection of known and unknown compounds, while modular design supports rapid field repairs.
Future trends and potential applications
Integration with advanced data management software will facilitate remote monitoring and real-time reporting. Expanding analyte lists and coupling with atmospheric modeling could improve source apportionment and regulatory compliance across urban and industrial environments.
Conclusion
The validated TD-GC-MS system delivers reliable, unattended, cryogen-free monitoring of EPA PAMS VOC precursors with high sensitivity, robust field maintenance, and comprehensive data quality, offering a modern alternative to legacy Auto-GC platforms.
References
- Council Directive 96/62/EC on ambient air quality assessment and management and Directive 2000/69/EC on benzene and carbon monoxide limit values.
- US Clean Air Act Amendments of 1990, Provisions for attainment and maintenance of national ambient air quality standards.
- Peters RJB et al., Atmospheric Environment, 1994, 28, 2413–2419.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Markes Air Server-xr
|Markes|Brochures and specifications
Air Server-xr Robust, cryogen-free, on-line air monitoring system Air Server-xr ™ Introducing the Air Server-xr – an on-line sampling device for the GC and GC–MS analysis of trace‑level volatile and semi‑volatile organic compounds (VOCs and SVOCs) from air and materials.…
Key words
kori, koriair, airserver, servermarkes, markestube, tubesampling, samplingline, linetrap, trapmonitoring, monitoringvoc, vocfocusing, focusingpolar, polarcollection, collectiontubes, tubeswater
Cryogen-free analysis of VOCs in car exhaust
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE 73566 Cryogen-free analysis of VOCs in car exhaust Thermal desorption coupled to gas chromatography with dual flame ionization detectors Authors: David Lee1, Terry Jeffers2, Cristian Cojocariu1, and David Wevill3 Thermo Fisher Scientific, Runcorn, UK 1 Thermo Fisher Scientific,…
Key words
none, noneethyltoluene, ethyltoluenedetected, detectedppbc, ppbckori, koritrap, trapcia, ciavocs, vocsdual, dualmarkes, markesdeans, deanspams, pamspurge, purgecompound, compoundpropane
Cryogen-free analysis of VOCs in car exhaust
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE 73566 Cryogen-free analysis of VOCs in car exhaust Thermal desorption coupled to gas chromatography with dual flame ionization detectors Authors: David Lee1, Terry Jeffers2, Cristian Cojocariu1, and David Wevill3 Thermo Fisher Scientific, Runcorn, UK 1 Thermo Fisher Scientific,…
Key words
none, noneethyltoluene, ethyltoluenedetected, detectedppbc, ppbckori, koritrap, trapcia, ciadual, dualvocs, vocsmarkes, markesdeans, deanspams, pamspurge, purgecompound, compoundpropane
Completely cryogen-free monitoring of ozone precursors, air toxics, and oxygenated volatile organic compounds in ambient air in a single run
2019|Thermo Fisher Scientific|Applications
APPLICATION NOTE 10706 Completely cryogen-free monitoring of ozone precursors, air toxics, and oxygenated volatile organic compounds in ambient air in a single run Authors Jane Cooper,1 Laura Miles,2 and Natasha D. Spadafora2 Thermo Fisher Scientific, Runcorn, UK; 2Markes International Ltd.,…
Key words
eic, eicpass, passair, airrsd, rsdqual, qualmarkes, markesdeans, deansresponse, responsecia, ciacompound, compoundcompounds, compoundscryogen, cryogenunity, unitymicrofluidic, microfluidicrrf