GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

IMPROVED Agilent J&W HP-INNOWax and Intuvo HP-INNOWax GC columns

Others | 2016 | Agilent TechnologiesInstrumentation
GC columns, Consumables
Industries
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Gas chromatography analyses of polar compounds demand high surface inertness to avoid adsorption, ensure accurate quantitation at trace levels, and maintain productivity. Robust column performance is crucial in environmental safety, food quality, and industrial quality control, where sample availability can be limited and reanalysis is costly.

Objectives and Study Overview


This study presents enhanced Agilent J&W HP-INNOWax and Intuvo HP-INNOWax GC columns. By incorporating the Ultra Inert manufacturing process, these columns aim to deliver improved peak shapes, extended inertness lifetimes, and greater column-to-column reproducibility without altering selectivity or retention characteristics.

Methodology and Instrumentation


  • A series of conditioning tests using a modified Grob mixture in dichloromethane at 250–260 °C assessed inertness longevity versus competitor columns.
  • FID chromatograms of a demanding test probe mixture evaluated peak shape and bleed after 50 h thermal conditioning.
  • Retention time-locked FAMEs mixture (72 compounds) compared standard and improved columns under a temperature program (50 °C hold, ramp to 200 °C, then to 230 °C).
  • Instrumentation included an Agilent 7890B GC with FID, Agilent G4513A autosampler, Ultra Inert flowpath components, and HP-INNOWax columns (30 m × 0.25 mm × 0.25 μm).

Key Results and Discussion


  • Improved columns maintained inertness after prolonged high-temperature conditioning, while competitor columns showed rapid activity loss.
  • Peak shapes for active polar analytes were markedly sharper with lower tailing.
  • Retention times remained consistent and matched those of standard HP-INNOWax columns, facilitating seamless method transfer.
  • No change in selectivity, theoretical plates, or retention indices ensured compatibility with established protocols.

Benefits and Practical Applications


  • Enhanced sensitivity and reproducibility for trace analysis of polar compounds in environmental, food, and industrial samples.
  • Extended column lifetime reduces downtime and maintenance costs.
  • Direct compatibility with existing methods allows prompt upgrades with minimal revalidation effort.

Future Trends and Potential Applications


  • Extension of Ultra Inert technology to additional stationary phases and GC/MS interfaces.
  • Development of columns tailored to emerging complex matrices in pharmaceuticals and bioanalysis.
  • Integration with high-throughput and automated GC workflows for real-time environmental monitoring.

Conclusion


The improved Agilent J&W HP-INNOWax and Intuvo HP-INNOWax columns deliver superior inertness, reliable peak performance, and consistent retention characteristics. These enhancements support accurate, reproducible analyses of polar compounds and streamline method implementation in diverse analytical settings.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
IMPROVED Agilent J&W HP-INNOWax and Intuvo HP-INNOWax GC columns
ENHANCE YOUR POLAR PEAK SHAPE ACCURATE. SENSITIVE. REPEATABLE. IMPROVED Agilent J&W HP-INNOWax and Intuvo HP-INNOWax GC columns Now your analysis of polar compounds can be even more worry free Flow path inertness is vital to any GC analysis. As the…
Key words
innowax, innowaxintuvo, intuvoimproved, improvedagilent, agilentvendor, vendorinertness, inertnesspolar, polarcolumn, columnwax, waxnreliable, nreliablelimits, limitsticking, tickingcolumns, columnswithstands, withstandsinert
Enhanced Performance of the Improved Agilent J&W HP-INNOWax Column
Enhanced Performance of the Improved Agilent J&W HP-INNOWax Column Improved Inertness and Column-to-column Quality Technical Overview Introduction In current GC and GC/MS applications, the sensitive and reproducible analysis of several highly active analytes at trace levels still poses a major…
Key words
innowax, innowaxinertness, inertnessimproved, improvedvendor, vendorcolumn, columnagilent, agilentwax, waxtest, testgrob, grobmaltol, maltolbenchmarking, benchmarkingcolumns, columnsmixture, mixtureactive, activeprobes
WAX Column Technology Update
WAX Column Technology Update
2018|Agilent Technologies|Presentations
WAX Column Technology Update Mark Sinnott August 14, 2018 1 August 14, 2018 Agilent J&W DB-HeavyWAX WAX Column Update • What is a WAX column? • Traditional WAX Phases • • • • • • 2 DB-WAX HP-INNOWAX VF-WAX MS…
Key words
heavywax, heavywaxwax, waxfatwax, fatwaxagilent, agilentcolumn, columnacids, acidsinert, inertcompetitor, competitordha, dhaacid, acidfame, famebleed, bleedffap, ffapultra, ultratraditional
Agilent GC AND GC/MS Columns Catalog
Agilent GC AND GC/MS Columns Catalog
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentcolumns, columnslength, lengthfilm, filmrinsable, rinsableultimetal, ultimetalltm, ltmitalicized, italicizedcolumn, columnbonded, bondedchromosorb, chromosorbtest, testdescriptions, descriptionsmesh, meshlinked
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike