GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Analysis of organophosphorous pesticides (USEPA 614.1)

Applications | 2016 | Trajan ScientificInstrumentation
GC/MSD, GC columns, Consumables
Industries
Manufacturer
Trajan Scientific
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Analysis of organochlorine pesticides (USEPA 608.1)
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of organochlorine pesticides (USEPA 608.1) BPX5 Column part number 054142 Phase BPX5 Detector MS Column 30 m x 0.22 mm x 0.25 μm Injection mode Splitless, 0.5 min Initial temperature 50°C, 1 min Carrier gas He, 30…
Key words
quad, quadtemperature, temperatureinjection, injectionfinal, finalcolumn, columninterface, interfaceinitial, initialpart, partcarrier, carriercomponents, componentssource, sourcedetector, detectornumber, numbervolume, volumemode
Analysis of USEPA 8270 mix
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of USEPA 8270 mix BPX5 Column part number 054101 Phase BPX5 Carrier gas flow 1.1 mL/min Column 30 m x 0.25 mm x 0.25 μm Constant flow On Sample 5 ppm solution Injection mode Splitless Initial temperature…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzoanthracene, anthracenepyrene, pyrenebutyl, butylpressure, pressurediethylphthalate, diethylphthalatepurge, purgefinal, finalnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoletemperature, temperatureinjection, injectionazobenzene
Analysis of organophosphorous pesticides (USEPA 614)
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of organophosphorous pesticides (USEPA 614) BPX5 Column part number 054142 Phase BPX5 Detector MS Column 30 m x 0.22 mm x 0.25 μm Injection mode Splitless, 0.5 min Initial temperature 50°C, 1 min Carrier gas He, 30…
Key words
quad, quadtemperature, temperatureinjection, injectionfinal, finalcolumn, columninterface, interfaceinitial, initialpart, partcarrier, carriercomponents, componentssource, sourcedetector, detectornumber, numbervolume, volumemode
Analysis of 16 synthetic pyrethroids
2016|Trajan Scientific|Applications
APPLICATION NOTE Analysis of 16 synthetic pyrethroids BPX5 Column part number 054101 Phase BPX5 Constant flow On Column 30 m x 0.25 mm x 0.25 μm Average linear velocity 35 cm/sec at 50°C Sample 10 ppm in methanol Injection mode…
Key words
sumithrin, sumithrinpurge, purgeesfenvalerate, esfenvalerateflucythrinate, flucythrinatetetramethrin, tetramethrintemperature, temperatureinjection, injectioncyfluthrin, cyfluthrinfenvalerate, fenvalerateflow, flowfenpropathrin, fenpropathrincypermethrin, cypermethrincarrier, carrierpermethrin, permethrinbifenthrin
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike