Applications - page 54

Marine Oil FAMEs - FAMEWAX™

Applications
| N/A | Restek
GC, GC columns, Consumables
Instrumentation
GC, GC columns, Consumables
Manufacturer
Restek
Industries
Food & Agriculture

Semivolatile GC-MS Tune Verification Mix on Rxi®-5Sil MS

Applications
| N/A | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Nitrosamines in Drinking Water on Rxi®-624Sil MS by Modified EPA Method 521 Utilizing CSR-LVSI

Applications
| N/A | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Florisil® SPE Cleanup of EPA 8081 Pesticides on Rtx®-CLPesticides2

Applications
| N/A | Restek
GC, Sample Preparation, GC columns, Consumables
Instrumentation
GC, Sample Preparation, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Brominated Flame Retardants on Rtx®-1614 After Approximately Two Loops Were Trimmed Off

Applications
| N/A | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx®-CLPesticides and Rtx®-CLPesticides2 Using Hydrogen

Applications
| N/A | Restek
GC, GC columns, Consumables
Instrumentation
GC, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

9-Minute Semivolatiles Analysis with Appendix IX on Rxi®-5ms by U.S. EPA Method 8270D

Applications
| N/A | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

PAHs in Sediment Extract on Rxi®-PAH (Sampled From Spring Creek, PA)

Applications
| N/A | Restek
GC/MSD, GC/TOF, GC columns, Consumables
Instrumentation
GC/MSD, GC/TOF, GC columns, Consumables
Manufacturer
Restek, LECO
Industries
Environmental

PAHs in Sediment Extract on Rxi®-PAH (Sampled From Spring Creek, PA)

Applications
| N/A | Restek
GC/MSD, GC/TOF, GC columns, Consumables
Instrumentation
GC/MSD, GC/TOF, GC columns, Consumables
Manufacturer
Restek, LECO
Industries
Environmental

PAHs in Sediment Extract on Rxi®-PAH (Sampled From Spring Creek, PA)

Applications
| N/A | Restek
GC/MSD, GC/TOF, GC columns, Consumables
Instrumentation
GC/MSD, GC/TOF, GC columns, Consumables
Manufacturer
Restek, LECO
Industries
Environmental
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike