GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Applications from OI Analytical - page 1

Comparison of Helium and Nitrogen Purge Gases for the Analysis of Volatile Organic Compounds (VOCs) by Purge and Trap

Applications
| 2019 | OI Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, OI Analytical
Industries
Environmental

Analysis of Impurities in Propane/Propylene Streams Using a Pulsed-Flame Photometric Detector (PFPD)

Applications
| N/A | OI Analytical
GC
Instrumentation
GC
Manufacturer
Agilent Technologies, OI Analytical
Industries
Energy & Chemicals

Analysis of Volatile Organic Compounds Using USEPA Method 524.3

Applications
| N/A | OI Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, OI Analytical
Industries
Environmental

Analysis of Organotin Compounds in Biological and Environmental Samples by Gas Chromatography and Pulsed Flame Photometric Detection (GC-PFPD)

Applications
| N/A | OI Analytical
GC
Instrumentation
GC
Manufacturer
Agilent Technologies, Shimadzu, OI Analytical
Industries
Environmental, Forensics , Clinical Research

Analysis of Thiophene in Benzene Using ASTM Method D7011 and a Pulsed Flame Photometric Detector (PFPD)

Applications
| N/A | OI Analytical
GC
Instrumentation
GC
Manufacturer
Agilent Technologies, OI Analytical
Industries
Energy & Chemicals

Analysis of Volatile Organic Compounds in Wine by Purge and Trap Concentration and Gas Chromatography/Mass Spectrometry (GC/MS)

Applications
| N/A | OI Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, OI Analytical
Industries
Food & Agriculture

2017 EPA Method Update Rule and EPA Method 624.1

Applications
| N/A | OI Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, OI Analytical
Industries
Environmental

Analysis of 1, 2, 3-Trichloropropane by Purge and Trap Concentration and Gas Chromatography/Mass Spectrometry (GC/MS)

Applications
| N/A | OI Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, OI Analytical
Industries
Environmental

Analysis of Impurities in Ethylene/Ethane and Propylene/Propane Streams Using a Pulsed Flame Photometric Detector (PFPD)

Applications
| N/A | OI Analytical
GC
Instrumentation
GC
Manufacturer
OI Analytical
Industries
Energy & Chemicals

USEPA Methods 502.2 and 8021B using the Eclipse Purge-and-Trap (P&T) Sample Concentrator and PID/ELCD Tandem Detectors

Applications
| N/A | OI Analytical
GC, Purge and Trap
Instrumentation
GC, Purge and Trap
Manufacturer
Agilent Technologies, OI Analytical
Industries
Environmental
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike