Applications focused on Purge and Trap - page 8

US EPA Method 524.3 with the Tekmar Lumin P & T Concentrator and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System

Applications
| 2017 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Thermo Fisher Scientific, Teledyne LABS
Industries
Environmental

US EPA Method 524.4 with the Tekmar Lumin P & T Concentrator and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System

Applications
| 2017 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Thermo Fisher Scientific, Teledyne LABS
Industries
Environmental

US EPA Method 624 with the Tekmar Lumin P&T Concentrator and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS

Applications
| 2017 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, Teledyne LABS
Industries
Environmental

US EPA Method 8260 with the Tekmar Lumin P&T Concentrator and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ MS

Applications
| 2017 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, Teledyne LABS
Industries
Environmental

CDS 7000C Purge and Trap Performance with CTC PAL Automation

Applications
| 2017 | CDS Analytical
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Shimadzu, CDS Analytical, CTC Analytics
Industries
Environmental

Rapid Determination of TO-15 Volatile Organic Compounds (VOCs) in Air

Applications
| 2016 | Restek
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

Optimize Analysis of Polar and Coeluting VOCs in Whole Air Canister Samples Using an Rtx®-VMS GC Column

Applications
| 2016 | Restek
GC/MSD, Thermal desorption, Purge and Trap, GC/SQ, Consumables
Instrumentation
GC/MSD, Thermal desorption, Purge and Trap, GC/SQ, Consumables
Manufacturer
Agilent Technologies, Markes, Restek
Industries
Environmental

US EPA Method 524.2 with the Teledyne Tekmar Lumin P&T Concentrator and Agilent 7890B GC / 5977A MS

Applications
| 2016 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, Teledyne LABS
Industries
Environmental

Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time

Applications
| 2016 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Agilent Technologies, Teledyne LABS
Industries
Environmental

USEPA Method 524.4 Using the Teledyne Tekmar Atomx and Thermo Scientific™ GC/MS System with New Helium Saver Module

Applications
| 2016 | Teledyne LABS
GC/MSD, Purge and Trap, GC/SQ
Instrumentation
GC/MSD, Purge and Trap, GC/SQ
Manufacturer
Thermo Fisher Scientific, Teledyne LABS
Industries
Environmental
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike