Applications focused on GC columns - page 38

EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rxi-5Sil MS (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rxi-5Sil MS (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

EPA Method 530 UCMR4 Standard at Method Reporting Limit on Rtx-1701 (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

EPA Method 530 UCMR4 Standard at 10x the Method Reporting Limit on Rtx-1701 (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

EPA Method 541 UCMR4 Standard at Method Reporting Limit on Stabilwax (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

EPA Method 541 UCMR4 Standard at 10x the Method Reporting Limit on Stabilwax (SIM)

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven

Applications
| 2017 | Restek
GC/MSD, GC/SQ, GC columns, Consumables
Instrumentation
GC/MSD, GC/SQ, GC columns, Consumables
Manufacturer
Agilent Technologies, Restek
Industries
Environmental

Improved Analysis of EPA Method 625 Using Large- Particle, Large-Pore Solid Phase Extraction (SPE)

Applications
| 2017 | Phenomenex
GC/MSD, Sample Preparation, GC columns, Consumables
Instrumentation
GC/MSD, Sample Preparation, GC columns, Consumables
Manufacturer
Shimadzu, Phenomenex
Industries
Environmental
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike