How to buy?
All the necessery information about the buying process is right here.
How to sell?
All the necessery information about the selling process is right here.

Marketplace products from category GC columns focused on GC columns from Agilent Technologies - page 1

Agilent Jumper Chip, Intuvo, split/splitless inlet, G4587-60575 (New)
Agilent Jumper Chip, Intuvo, split/splitless inlet, G4587-60575 (New)

Agilent Intuvo Jumper Chip for split/splitless inlets enables direct inlet-to-column connection, simplifying GC configuration for diagnostics, method development, and specialized analyses.

Purchase price80without VAT
In stock
Detail
Agilent J&W HP-5 GC Column, 30 m × 0.32 mm × 0.25 µm, 7 inch cage (Tested)
Agilent J&W HP-5 GC Column, 30 m × 0.32 mm × 0.25 µm, 7 inch cage (Tested)

Agilent HP-5 GC column, 30 m × 0.32 mm × 0.25 µm, low-polarity phase for general-purpose GC. Standard 7-inch format compatible with Agilent 5890–8890 and most GC systems.

Purchase price350without VAT
In stock
Detail
Agilent J&W HP-5 GC Column, 30 m × 0.32 mm × 0.25 µm, with Smart Key (New)
Agilent J&W HP-5 GC Column, 30 m × 0.32 mm × 0.25 µm, with Smart Key (New)

HP-5 GC column (30 m × 0.32 mm × 0.25 µm) with Smart Key for Agilent 8890. Offers low bleed, wide analyte range, and automatic column recognition for easy GC setup.

Purchase price450without VAT
In stock
Detail
Agilent Deactivated Fused Silica Tubing, 10 m × 0.18 mm, 160-2615-10 (New)
Agilent Deactivated Fused Silica Tubing, 10 m × 0.18 mm, 160-2615-10 (New)

Agilent 10 m × 0.18 mm deactivated fused silica tubing provides inert, high-quality sample transfer for GC systems, ideal for retention gaps, transfer lines, and reactive analytes.

Purchase price80without VAT
In stock
Detail
Agilent Deactivated Fused Silica Tubing, 5 m × 0.2 mm, 160-2205-5 (New)
Agilent Deactivated Fused Silica Tubing, 5 m × 0.2 mm, 160-2205-5 (New)

Agilent 5 m × 0.20 mm deactivated fused silica tubing ensures inert, high-quality transfer for GC applications—ideal for retention gaps, transfer lines, and reactive analytes.

Purchase price40without VAT
In stock
Detail
Agilent Deactivated Fused Silica Tubing, 5 m × 0.1 mm, 160-2635-5 (New)
Agilent Deactivated Fused Silica Tubing, 5 m × 0.1 mm, 160-2635-5 (New)

Agilent 5 m × 0.10 mm deactivated fused silica tubing offers ultra-inert, low-volume sample transfer for fast GC, retention gaps, and applications requiring minimized analyte interaction.

Purchase price70without VAT
In stock
Detail
Agilent J&W HP-5ms Ultra Inert Intuvo GC column, 30 m, 0.25 mm, 0.25 µm (Tested)
Agilent J&W HP-5ms Ultra Inert Intuvo GC column, 30 m, 0.25 mm, 0.25 µm (Tested)

Agilent J&W HP-5ms Ultra Inert Intuvo GC column (30 m × 0.25 mm × 0.25 µm) provides exceptional inertness and thermal stability for trace-level analysis on Intuvo 9000 GC.

Purchase price500without VAT
In stock
Detail
Agilent J&W HP-5ms Ultra Inert Intuvo GC column, 30 m, 0.25 mm, 0.25 µm (Tested)
Agilent J&W HP-5ms Ultra Inert Intuvo GC column, 30 m, 0.25 mm, 0.25 µm (Tested)

HP-5ms Ultra Inert Intuvo column (30 m × 0.25 mm × 0.25 µm) delivers exceptional inertness, sensitivity, and Smart Key tracking for robust GC-MS analysis on Intuvo 9000.

Purchase price500without VAT
In stock
Detail
Agilent J&W DB-5ms Ultra Inert Intuvo GC column, 20 m, 0.18 mm, 0.36 µm (Tested)
Agilent J&W DB-5ms Ultra Inert Intuvo GC column, 20 m, 0.18 mm, 0.36 µm (Tested)

Agilent DB-5ms Ultra Inert Intuvo GC column (20 m × 0.18 mm × 0.36 µm) delivers exceptional inertness and reproducibility for sensitive GC-MS analysis on the Intuvo 9000 GC system.

Purchase price450without VAT
In stock
Detail
Agilent J&W VF-624ms Intuvo GC column, 20 m, 0.15 mm, 0.84 µm (Tested)
Agilent J&W VF-624ms Intuvo GC column, 20 m, 0.15 mm, 0.84 µm (Tested)

Agilent VF-624ms Intuvo GC column (20 m × 0.15 mm × 0.84 µm) delivers mid-polarity selectivity and low bleed for sensitive GC/MS analysis on the Agilent Intuvo 9000 system.

Purchase price450without VAT
In stock
Detail
How to buy?
All the necessery information about the buying process is right here.
How to sell?
All the necessery information about the selling process is right here.
 

Related content

Researchers Tereza Nešporová and Jaroslava Večerková: In science, we must learn to work with failure

Researchers Tereza Nešporová and Jaroslava Večerková: In science, we must learn to work with failure

Th, 9.7.2026
RECETOX - Centrum pro výzkum toxických látek v prostředí
News from LabRulezGCMS Library - Week 28, 2026

News from LabRulezGCMS Library - Week 28, 2026

We, 8.7.2026
LabRulez
Wiley Releases NIST Mass Spectral Library 2026 in Multiple Instrument-Ready Formats

Wiley Releases NIST Mass Spectral Library 2026 in Multiple Instrument-Ready Formats

Tu, 7.7.2026
Wiley
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike