Application 265-00 Agilent Monomer Analyzer
Aplikace | 2002 | Agilent TechnologiesInstrumentation
GC
IndustriesPrůmysl a chemie
ManufacturerAgilent Technologies, Wasson-ECE Instrumentation
Key wordsacetylene, monomer, isoprene, pentane, propylene, styrene, ethyl, isobutylene, impurities, propadiene, isobutane, acrylonitrile, butane, vinyl, highlights, configurations, msd, benzene, min, analyzer, optional, chloride, grade, purity, printed, overview, methyl, usa, technical, agilent, more, information, application, high, analysis
Similar PDF
Application 262-00 Agilent Monomer Analyzer
2002|Agilent Technologies|Technical notes
Application 262-00 Agilent Monomer Analyzer Impurities in Polymer Grade Ethylene and Polymer Grade Propylene Technical Overview Application Highlights Optional Configurations Dual Flame Ionization Detectors (FID) • • • • Method 1 performs the trace impurities analysis in polymer-grade ethylene. Method…
Key words
isobutane, isobutanepropadiene, propadieneacetylene, acetylenepropylene, propylenemethane, methanebutane, butaneethane, ethanepropane, propaneethylene, ethylenemonomer, monomergrade, gradeimpurities, impuritiesisobutene, isobutenepolymer, polymerisoprene
Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene
2012|Agilent Technologies|Aplikace
Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene Application Note Hydrocarbon processing industry Author Abstract Chunxiao Wang An improved gas chromatographic method based on an Agilent 7890 Series GC for the Agilent Technologies (Shanghai)…
Key words
acetylene, acetylenepropyne, propynebutane, butaneiso, isopentane, pentanedimer, dimerpropadiene, propadienevinyl, vinylbackflushing, backflushinghpli, hpliethyl, ethylvalve, valvepropylene, propylenepropane, propaneimpurities
Hydrocarbon Analysis of Reference Standard for Impurities in 1,3 butadiene for ASTM method
|SCION Instruments|Aplikace
Hydrocarbon Analysis of Reference Standard for Impurities in 1,3-butadiene for ASTM method Application Note AN0050 SCION GC-FID GC-FID conditions Injector LSV 1:10000 Sample 1µL Column SCION Al2O3 50m x 0.32mm x 5µm Oven 40°C (6 min) to 160°C at 5°C/min…
Key words
scion, scionfid, fidmethylacetylene, methylacetylenecyclopropane, cyclopropaneisobutylene, isobutylenepropadiene, propadieneisoprene, isopreneisopentane, isopentaneisobutane, isobutaneinstruments, instrumentsacetylene, acetylenebutane, butanepropane, propanepentane, pentanepropylene
Agilent 7890 Series GC with Prefractionator for Reliable Analysis of Crude Butadiene and Mixed C4 Streams 
2012|Agilent Technologies|Aplikace
Agilent 7890 Series GC with Prefractionator for Reliable Analysis of Crude Butadiene and Mixed C4 Streams Application Note Hydrocarbon processing industry Author Abstract Chunxiao Wang A previous application note [1] shows that an Agilent 7890 Series GC configured with Agilent…
Key words
iso, isobutane, butanepentane, pentanepropyne, propynebutylene, butylenebackflushing, backflushingpropadiene, propadienepropane, propanepropylene, propylenehpli, hplialumina, aluminadimer, dimerstdev, stdevbackflush, backflushcft