Improved Sensitivity and Dynamic Range Using the Clarus SQ 8 GC/MS System for EPA Method 8270D Semi-Volatile Organic Compound Analysis
Applications | 2011 | PerkinElmerInstrumentation
GC/MSD, GC/SQ
IndustriesEnvironmental
ManufacturerPerkinElmer
Key wordsclarifi, benzo, phthalate, scan, range, fluoranthene, concentration, rrf, bfb, providing, were, level, benzyl, kaplan, yury, analyses, anthracene, pyrene, ultratune, voltage, detector, calibration, wide, fluoroanthene, garnica, ruben, semi, butyl, wishing, provide, presented, min, sensitivity, diethylphthalate, dynamic, laboratories, volatile, demonstrates, perform, fortification, adjusts, low, initial, nitrosodiphenylamine, average, carbazole, dftpp, achieved, azobenzene, time
Similar PDF
Optimized GC-MS solution for semivolatiles (SVOC) analysis in environmental samples in compliance with the U.S. EPA Method 8270D
2018|Thermo Fischer Scientific|Applications
APPLICATION NOTE 10522 Optimized GC-MS solution for semivolatiles (SVOC) analysis in environmental samples in compliance with the U.S. EPA Method 8270D Authors Richard Law,1 Cristian Cojocariu,1 Daniela Cavagnino2 Thermo Fisher Scientific, Runcorn, UK 1 2 Thermo Fisher Scientific, Milan, Italy…
Key words
phthalate, phthalatefluoranthene, fluoranthenebenzo, benzosaver, saveranthracene, anthracenepyrene, pyrenebenzyl, benzylpass, passmin, minbutyl, butylsplitless, splitlesschloroaniline, chloroanilineoctylphthalate, octylphthalatehelium, heliumboldface
Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8
2012|PerkinElmer|Applications
a p p l i c at i o n N o t e Gas Chromatography/ Mass Spectrometry Authors Ruben Garnica Dawn May PerkinElmer, Inc. Shelton, CT USA Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the…
Key words
temp, tempbake, bakepurge, purgerrf, rrfsweep, sweeprinse, rinsedesorb, desorbcondensate, condensateclarifi, clarifitime, timemdl, mdlflow, flowavg, avgrsd, rsdsetting
Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8
2012|PerkinElmer|Applications
a p p l i c at i o n N o t e Gas Chromatography/ Mass Spectrometry Authors Ruben Garnica Dawn May PerkinElmer, Inc. Shelton, CT USA Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the…
Key words
temp, tempbake, bakepurge, purgerrf, rrfsweep, sweeprinse, rinsedesorb, desorbcondensate, condensateclarifi, clarifitime, timeflow, flowmdl, mdlavg, avgrsd, rsdsetting
Analysis of Semivolatile Organic Compounds Using Hydrogen Carrier Gas and the Agilent HydroInert Source by Gas Chromatography/Mass Spectrometry
2022|Agilent Technologies|Applications
Application Note Environmental Analysis of Semivolatile Organic Compounds Using Hydrogen Carrier Gas and the Agilent HydroInert Source by Gas Chromatography/Mass Spectrometry Author Angela Smith Henry, PhD Agilent Technologies, Inc. Abstract Gas chromatography/mass spectrometry (GC/MS) is integral to the analysis of…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluoranthenepass, passnitrobenzene, nitrobenzeneanthracene, anthracenearamite, aramitelinear, linearmethanesulfonate, methanesulfonatediallate, diallatepyrene, pyrenehydroinert, hydroinertazobenzene, azobenzenenitroso, nitrosobenzyl