EPA 8270 Re-optimized for Widest Calibration Range on the 5977 Inert Plus GC/MSD | LabRulez GCMS_EN
 

Similar PDF

Toggle
Application BriefAnalysis of Semivolatile OrganicCompounds in Drinking Water onthe Agilent Intuvo and 5977 WithExtended Calibration RangeTechnology advantage:Agilent Intuvo 9000 GC with MSDAuthorMatthew Giardina, Ph.D.Agilent Technologies, Inc.IntroductionMany government regulatory agencies throughout the world have establisheddirectives for monitoring organic contaminants in drinking...
Key words
benzo, benzocalibration, calibrationdraw, drawaverage, averageconcentration, concentrationghi, ghiperylene, peryleneanthracene, anthraceneendrin, endrinresponse, responsecalculated, calculatedregression, regressionrsd, rsderror, errorout
Application NoteEnvironmentalA Fast Method for EPA 8270 in MRMMode Using the 7000 Series TripleQuadrupole GC/MSAuthorsMelissa Churley,Bruce Quimby, andAnastasia AndrianovaAgilent Technologies, Inc.IntroductionA fast method for EPA 8270D/E has been developed for the Agilent 7000 seriestriple quadrupole GC/MS system in multiple reaction...
Key words
phthalate, phthalatedelta, deltafluoranthene, fluoranthenebenzo, benzoquadratic, quadraticbenzyl, benzylcalibration, calibrationaverage, averageanthracene, anthracenepyrene, pyrenegain, gainion, ioncriteria, criterialeft, leftfit
Application BriefEnvironmentalEPA 8270 Re-optimized for WidestCalibration Range on the 5977 InertPlus GC/MSDAuthorsMelissa Churley,Mike Szelewski, andBruce QuimbyAgilent Technologies, Inc.IntroductionThe methodology described within United States EPA Method 8270 for theanalysis of semivolatile organic compounds by GC/MS is applicable to otherregions worldwide. The...
Key words
calibration, calibrationrange, rangeaverage, averageexceptions, exceptionsresponse, responserelative, relativecriteria, criterianumber, numberfactor, factorbatches, batchestaper, taperisomer, isomerpractical, practicalfluoranthene, fluoranthenecompound
Application NoteEnvironmentalFull Scan Quantitative Analysis ofSemivolatile Organic CompoundsEvaluating the performance of an Agilent 7000DGC/TQ in full scan data acquisition mode forSVOCs analysisAuthorsAnastasia A. Andrianova andBruce D. QuimbyAgilent Technologies, Inc.AbstractThe Agilent 7000D triple quadrupole GC/MS system (GC/TQ) operating in full scandata...
Key words
scan, scanfull, fullbenzo, benzosvocs, svocsfluoranthene, fluoranthenemsd, msdlibrary, libraryphthalate, phthalateacquisition, acquisitionmode, modeagainst, againstdata, datacompounds, compoundsretention, retentionaverage
 

Similar PDF

Toggle
Application BriefAnalysis of Semivolatile OrganicCompounds in Drinking Water onthe Agilent Intuvo and 5977 WithExtended Calibration RangeTechnology advantage:Agilent Intuvo 9000 GC with MSDAuthorMatthew Giardina, Ph.D.Agilent Technologies, Inc.IntroductionMany government regulatory agencies throughout the world have establisheddirectives for monitoring organic contaminants in drinking...
Key words
benzo, benzocalibration, calibrationdraw, drawaverage, averageconcentration, concentrationghi, ghiperylene, peryleneanthracene, anthraceneendrin, endrinresponse, responsecalculated, calculatedregression, regressionrsd, rsderror, errorout
Application NoteEnvironmentalA Fast Method for EPA 8270 in MRMMode Using the 7000 Series TripleQuadrupole GC/MSAuthorsMelissa Churley,Bruce Quimby, andAnastasia AndrianovaAgilent Technologies, Inc.IntroductionA fast method for EPA 8270D/E has been developed for the Agilent 7000 seriestriple quadrupole GC/MS system in multiple reaction...
Key words
phthalate, phthalatedelta, deltafluoranthene, fluoranthenebenzo, benzoquadratic, quadraticbenzyl, benzylcalibration, calibrationaverage, averageanthracene, anthracenepyrene, pyrenegain, gainion, ioncriteria, criterialeft, leftfit
Application BriefEnvironmentalEPA 8270 Re-optimized for WidestCalibration Range on the 5977 InertPlus GC/MSDAuthorsMelissa Churley,Mike Szelewski, andBruce QuimbyAgilent Technologies, Inc.IntroductionThe methodology described within United States EPA Method 8270 for theanalysis of semivolatile organic compounds by GC/MS is applicable to otherregions worldwide. The...
Key words
calibration, calibrationrange, rangeaverage, averageexceptions, exceptionsresponse, responserelative, relativecriteria, criterianumber, numberfactor, factorbatches, batchestaper, taperisomer, isomerpractical, practicalfluoranthene, fluoranthenecompound
Application NoteEnvironmentalFull Scan Quantitative Analysis ofSemivolatile Organic CompoundsEvaluating the performance of an Agilent 7000DGC/TQ in full scan data acquisition mode forSVOCs analysisAuthorsAnastasia A. Andrianova andBruce D. QuimbyAgilent Technologies, Inc.AbstractThe Agilent 7000D triple quadrupole GC/MS system (GC/TQ) operating in full scandata...
Key words
scan, scanfull, fullbenzo, benzosvocs, svocsfluoranthene, fluoranthenemsd, msdlibrary, libraryphthalate, phthalateacquisition, acquisitionmode, modeagainst, againstdata, datacompounds, compoundsretention, retentionaverage
 

Related content

Method for the determination of 431 Residual Pesticides in Honey using LCMS-8050 and GCMS-TQ8040 NX

Applications
| 2022 | Shimadzu
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Shimadzu
Industries
Food & Agriculture

Determination of Multiclass, Multiresidue Pesticides in Berries

Applications
| 2022 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, Sample Preparation, GC/QQQ, Consumables
Manufacturer
Agilent Technologies
Industries
Food & Agriculture

Increased laboratory efficiency with the TSQ 9610 GC-MS/MS in a food and environmental analytical laboratory

Others
| 2022 | Thermo Fischer Scientific
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fischer Scientific
Industries
Environmental, Food & Agriculture

Enhanced Quantitative Analysis of Polychlorinated Paraffins by Comprehensive GCxGC-HRTOFMS with Negative Chemical Ionization

Applications
| 2022 | LECO
Instrumentation
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Manufacturer
Agilent Technologies, LECO
Industries
Environmental

Importance of Liner Selection in Aqueous Solution Analysis

Technical notes
| 2022 | Shimadzu
Instrumentation
GC, Consumables
Manufacturer
Shimadzu
Industries
---
 

Related content

Method for the determination of 431 Residual Pesticides in Honey using LCMS-8050 and GCMS-TQ8040 NX

Applications
| 2022 | Shimadzu
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, LC/MS, LC/MS/MS, LC/QQQ
Manufacturer
Shimadzu
Industries
Food & Agriculture

Determination of Multiclass, Multiresidue Pesticides in Berries

Applications
| 2022 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, Sample Preparation, GC/QQQ, Consumables
Manufacturer
Agilent Technologies
Industries
Food & Agriculture

Increased laboratory efficiency with the TSQ 9610 GC-MS/MS in a food and environmental analytical laboratory

Others
| 2022 | Thermo Fischer Scientific
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fischer Scientific
Industries
Environmental, Food & Agriculture

Enhanced Quantitative Analysis of Polychlorinated Paraffins by Comprehensive GCxGC-HRTOFMS with Negative Chemical Ionization

Applications
| 2022 | LECO
Instrumentation
GCxGC, GC/MSD, GC/HRMS, GC/TOF
Manufacturer
Agilent Technologies, LECO
Industries
Environmental

Importance of Liner Selection in Aqueous Solution Analysis

Technical notes
| 2022 | Shimadzu
Instrumentation
GC, Consumables
Manufacturer
Shimadzu
Industries
---
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use

LabRulez s.r.o., all rights reserved.