Automatic Drift Correction for High Resolution Mass Spectrometry
Technical notes | 2019 | LECOInstrumentation
GC/MSD, GC/HRMS, GC/TOF
IndustriesManufacturerLECO
Key wordsmass, drift, correction, automatic, accuracy, tof, calibration, tofs, chromatof, jaloszynski, assignment, artaev, viatcheslav, generates, unfiltered, data, assigned, nanoseconds, ion, finding, fitted, peaks, flight, define, acenaphtylene, external, jonathan, confidence, polynomial, dependency, high, errors, routine, spectrum, significantly, multiplied, routines, empowering, incoming, improved, addressing, adc, internal, saturation, essentially, statistics, shifts, possibly, analyte, compositions
Similar PDF
High Resolution Deconvolution® Technical Brief
2019|LECO|Technical notes
High Resolution Deconvolution® Technical Brief Section 1 Pre-Requisites for Peak Finding High Resolution Deconvolution (HRD®) finds independent chemical components in complex chromatograms that may contain multiple partially overlapped peaks. By adding the extra capability of mathematical separation to chromatographic data,…
Key words
peak, peaksubpeak, subpeakmarkers, markersdata, datafinding, findingprocessing, processinganalyte, analytechemically, chemicallymasses, massestrue, truehrd, hrdcan, cantable, tablemass, massspectral
7200 Series Q-TOF for GC/MS - A new analytical tool for solving complex analytical problems
2011|Agilent Technologies|Presentations
7200 Series Q-TOF for GC/MS A new analytical tool for solving complex analytical problems June 2011 Page 1 ASMS Conference on Mass Spectrometry and Allied Topics June 5-9, 2011 Colorado Convention Center, Denver, CO 7200 GC/Q-TOF Breakfast Seminar Page 2…
Key words
mass, masstof, tofirm, irmion, ionformula, formuladefect, defectdeconvolution, deconvolutioncentroid, centroidfluorotelomer, fluorotelomerphotodegradation, photodegradationaccurate, accurateresolving, resolvingsource, sourceunknowns, unknownsmatrix
Time of Flight Mass Spectrometry
2011|Agilent Technologies|Technical notes
Time-of-Flight Mass Spectrometry Technical Overview Introduction Time-of-flight mass spectrometry (TOF MS) was developed in the late 1940’s, but until the 1990’s its popularity was limited. Recent improvements in TOF technology, including orthogonal acceleration, ion mirrors (reflectron), and high-speed electronics, have…
Key words
tdc, tdcmass, masstof, tofion, ionflight, flightarrival, arrivalconverter, converteradc, adctime, timeions, ionstransient, transientdigital, digitalabdcontaminant, abdcontaminantdynamic, dynamicsignal
Time-of-Flight Mass Spectrometry
2011|Agilent Technologies|Technical notes
Time-of-Flight Mass Spectrometry Technical Overview Introduction Time-of-flight mass spectrometry (TOF MS) was developed in the late 1940’s, but until the 1990’s its popularity was limited. Recent improvements in TOF technology, including orthogonal acceleration, ion mirrors (reflectron), and high-speed electronics, have…
Key words
tdc, tdcmass, masstof, tofion, ionflight, flightarrival, arrivalconverter, converteradc, adctime, timeions, ionstransient, transientdigital, digitaldynamic, dynamicabdcontaminant, abdcontaminantsignal