PCBs - Analysis of PCBs using comprehensive GC x GC
Applications | 2011 | Agilent TechnologiesInstrumentation
GCxGC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Key wordspcbs, odulator, biphenyls, polychlorinated, courtesy, printed, comprehensive, injector, usa, size, authors, program, environmental, technique, sample, analysis, carrier, columns, pressure, agilent, two, detector, note, conditions, gas, application, introduction, used, using
Similar PDF
Dioxins and benzofurans - Analysis of dioxins and benzofurans via comprehensive GC x GC
2011|Agilent Technologies|Applications
Dioxins and benzofurans Analysis of dioxins and benzofurans via comprehensive GC x GC Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of dioxins and benzofurans by GC, with a PDMS phase equivalent to Agilent VF-1ms, and Agilent VF-23ms, is…
Key words
benzofurans, benzofuransdioxins, dioxinsodulator, odulatorcourtesy, courtesyprinted, printedvia, viacomprehensive, comprehensiveinjector, injectorusa, usasize, sizeauthors, authorsprogram, programenvironmental, environmentaltechnique, techniquesample
Multi-residue Analysis of PAHs, PCBs and OCPs using an Agilent J&W FactorFour VF-35ms Column
2010|Agilent Technologies|Applications
Multi-residue Analysis of PAHs, PCBs and OCPs using an Agilent J&W FactorFour VF-35ms Column Application Note Author Introduction Laura Provoost Agilent Technologies, Inc. Multi-residue analysis involves the separation of different groups of compounds in a single operation. One of the…
Key words
heptachlor, heptachlorfluoranthene, fluoranthenebenzo, benzoepoxide, epoxidehch, hchminutes, minutestrans, transendosulfan, endosulfancis, cischlordane, chlordaneendrin, endrinanthracene, anthracenepyrene, pyreneprovoost, provoostlaura
PCBs/pesticides - Single column separation of pesticides and PCBs
2011|Agilent Technologies|Applications
PCBs/pesticides Single column separation of pesticides and PCBs Application Note Environmental Authors Introduction Agilent Technologies, Inc. The Agilent CP-Sil 5/C18 for PCB column is one of the most apolar phases of standard columns in routine capillary GC. It has a…
Key words
pcbs, pcbspesticides, pesticidesgap, gapcourtesy, courtesyprinted, printedcolumn, columninjector, injectorusa, usasize, sizeauthors, authorsenvironmental, environmentaltechnique, techniquesample, samplecarrier, carrieridentification
Multi-residue Analysis of PAHs, PCBs and OCPs on an Agilent J&W FactorFour VF-5ms GC Column
2010|Agilent Technologies|Applications
Multi-residue Analysis of PAHs, PCBs and OCPs on an Agilent J&W FactorFour VF-5ms GC Column Application Note Author Introduction Laura Provoost Agilent Technologies, Inc. During multi-residue analyses, different groups of compounds are analyzed in a single run. Reducing time is…
Key words
fluoranthene, fluoranthenebenzo, benzoheptachlor, heptachlorhch, hchminutes, minutesepoxide, epoxideendosulfan, endosulfantrans, transcis, cischlordane, chlordaneendrin, endrinanthracene, anthracenepyrene, pyreneprovoost, provoostlaura