GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer

Applications | 2012 | GERSTELInstrumentation
GC/MSD, Thermal desorption, Pyrolysis, GC/SQ
Industries
Materials Testing
Manufacturer
Agilent Technologies, GERSTEL
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Application Note Environmental Accelerated Determination of Microplastics in Environmental Samples Using Thermal Extraction Desorption-Gas Chromatography/Mass Spectrometry (TED-GC/MS) Authors Ulrike Braun, Paul Eisentraut, Korinna Altmann, Maria Kittner, and Erik Dümichen Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany Kurt Thaxton and…
Key words
ted, tedpolymers, polymerssbr, sbrpet, petpolymer, polymerdecomposition, decompositiontga, tgamps, mpsacrylate, acrylateenvironmental, environmentalthermal, thermalsamples, samplesmicroplastics, microplasticscompost, compostmass
GERSTEL Application Note No. 212, 2020 Determination of Microplastics using Pyrolysis Gas Chromatography Mass Spectrometry Jackie Whitecavage, John R. Stuff and Laurel Vernarelli GERSTEL, Inc., 701 Digital Drive, Suite J, Linthicum, MD, 21090, USA KEYWORDS Pyrolysis, smart ramped pyrolysis, fractionated…
Key words
pyrolysis, pyrolysisgerstel, gerstelmicroplastics, microplasticspolypropylene, polypropylenelakes, lakesmps, mpsquartz, quartzpyro, pyrohexamethyltrisiloxane, hexamethyltrisiloxanesrp, srppolyethylene, polyethyleneramped, rampedsamples, sampleswere, werefacial
AppNote 4/2011 Versatile Automated Pyrolysis GC Combining a Filament Type Pyrolyzer with a Thermal Desorption Unit Eike Kleine-Benne, Bernd Rose Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1, D-45473 Mülheim an der Ruhr, Germany KEYWORDS Pyrolysis GC, Automated Pyrolysis, Thermal Desorption…
Key words
pyrolysis, pyrolysisgerstel, gersteldesorption, desorptionmacromolecules, macromoleculesthermal, thermalsample, samplepyrolyzer, pyrolyzerdesign, designperformed, performedsolvent, solventpolymer, polymerfocusing, focusingpath, pathsplitless, splitlessholders
Analysis of Microplastic Samples using Pyrolysis Gas Chromatography Mass Spectrometry Instrumentation. Analysis conditions. solvent vent (50 mL/min), split transfer 75:1 -120°C; 12°C/sec; 325°C (3min) Pneumatics: He, constant flow, 1 mL/min Column: 30 m DB-5MS UI (Agilent) di = 0.25 mm…
Key words
pyrolysis, pyrolysispolypropylene, polypropyleneplastic, plasticgerstel, gerstelhexamethyltrisiloxane, hexamethyltrisiloxanepolyethylene, polyethylenemps, mpssediment, sedimentquartz, quartzmethylstyrene, methylstyrenesamples, samplesstyrene, styreneended, endedmicroplastic, microplastictdu
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike