ANALYSIS OF BLOOD PLASMA- COMPARING GC-MS AND SIFT-MS
Applications | 2020 | AnatuneInstrumentation
GC/MSD, GC/MS/MS, HeadSpace, GC/QQQ, SIFT-MS
IndustriesClinical Research
ManufacturerAgilent Technologies, GERSTEL, Syft Technologies
Key wordsanatune, sift, plasma, chromatograpic, analysed, metabolite, batch, second, samples, were, ltd, elevated, slightly, blood, all, comparing, headspace, unknown, greater, showed, against, significantly, either, techniques, selectivity, coupled, autosampler, calculated, containing, instrumentation, result, determined, from, first, automated, concentrations, many, higher, analyte, after, provided, extraction, provides, standards, its, separation, conclusion, two, concentration, chromatography
Similar PDF
AUTOMATED SIFT-MS: STATIC HEADSPACE ANALYSIS
2020|GERSTEL|Applications
AS236 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 | email: [email protected] | anatune.co.uk AUTOMATED SIFT-MS: STATIC HEADSPACE ANALYSIS Mark Perkins, Anatune Ltd., Girton, Cambridgeshire…
Key words
sift, siftincubation, incubationsignificant, significantautomated, automatedleg, legdog, dogadd, addheadspace, headspacedifference, differencebuilds, buildsanatune, anatuneconsequence, consequenceruntime, runtimeshown, showngains
SPECIATION OF DICHLOROMETHANE AND CHLOROFORM USING NEGATIVE ION SIFT-MS
|GERSTEL|Applications
AS233 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 | email: [email protected] | anatune.co.uk SPECIATION OF DICHLOROMETHANE AND CHLOROFORM USING NEGATIVE ION SIFT-MS Mark Perkins,…
Key words
chlorofor, chloroforsift, siftchloroform, chloroformppmv, ppmvheadspace, headspacedichloromethane, dichloromethanebranching, branchinglinearity, linearityconcentratio, concentratiorounding, roundingsuites, suitesrepeatability, repeatabilityreaction, reactionconstants, constantsion
Use of the SIFT-MS for a selection of Health and Safety Applications
2017|Syft Technologies|Technical notes
Anatune Ltd Unit 4, Wellbrook Court, Girton Road, Cambridge, CB3 0NA, UK Tel: +44 (0) 1223279210 Fax: +44 (0) 1223279253 Email: [email protected] Internet: www.anatune.co.uk Copyright © 2018 Anatune Ltd. All Rights Reserved. Anatune is a trademark of Anatune Ltd. Preliminary…
Key words
sift, siftpreliminary, preliminaryconcentration, concentrationreagent, reagentmeasurements, measurementsppbv, ppbvair, airrelease, releasexylenes, xylenesselected, selectedvehicle, vehicletube, tubereaction, reactionanalysed, analysedvial
Preliminary Investigation of a Range of Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) Applications
2015|GERSTEL|Technical notes
Anatune Ltd Unit 4, Wellbrook Court, Girton Road, Cambridge, CB3 0NA, UK Tel: +44 (0) 1223279210 Fax: +44 (0) 1223279253 Email: [email protected] Internet: www.anatune.co.uk Copyright © 2018 Anatune Ltd. All Rights Reserved. Anatune is a trademark of Anatune Ltd. Preliminary…
Key words
sift, siftpreliminary, preliminaryconcentration, concentrationreagent, reagentmeasurements, measurementsppbv, ppbvair, airrelease, releasexylenes, xylenesselected, selectedvehicle, vehicletube, tubereaction, reactionanalysed, analysedvial