Automated Dilution of Samples Using US EPA Method 8260 on the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with an Advanced Electron Ionization (AEI) Source
Applications | 2019 | Teledyne LABSInstrumentation
GC/MSD, Purge and Trap, GC/SQ
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific, Teledyne LABS
Key wordstemp, bake, acetate, tert, ether, purge, dilutions, methyl, butyl, precision, butylbenzene, xyz, atomx, accuracy, rinse, table, desorb, sweep, teledyne, tekmar, time, chloride, ethyl, amyl, methacrylate, iii, vinyl, surr, compound, rsd, variable, chloroprene, pentafluorobenzene, flow, carbon, methacrylonitrile, dibromofluoromethane, propionitrile, aei, pentachloroethane, isopropyltoluene, isobutanol, mcs, diisopropyl, dry, acrylate, hexachloroethane, allyl, acrylonitrile, water
Similar PDF
US EPA Method 8260 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with Advanced Electron Ionization (AEI) Source
2019|Thermo Fisher Scientific|Applications
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1908 P+T VOC ENV US EPA Method 8260 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with Advanced Electron Ionization (AEI) Source Amy Nutter, Applications Chemist; Teledyne…
Key words
temp, temppurge, purgebake, bakedesorb, desorbrinse, rinsesweep, sweeptert, tertacetate, acetateether, ethertime, timecondensate, condensateaverage, averagevariable, variablemethyl, methylbutyl
US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ MS
2018|Thermo Fisher Scientific|Applications
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1803 P+T VOC ENV US EPA Method 8260 with the Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA…
Key words
temp, temppurge, purgebake, bakeacetate, acetatedesorb, desorbrinse, rinseppb, ppbtert, tertsweep, sweepether, ethertime, timecondensate, condensateaverage, averagemethyl, methylbutyl
US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS
2017|Agilent Technologies|Applications
US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Application Note Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA Method 8260 in conjunction with Methods 5030 and…
Key words
temp, temppurge, purgebake, bakeppb, ppbacetate, acetatedesorb, desorbrinse, rinseaverage, averagesweep, sweeptert, tertatomx, atomxrsd, rsdether, etherxyz, xyzmcs
US EPA Method 8260 Using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1801 P+T VOC ENV US EPA Method 8260 Using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source Amy Nutter, Applications Chemist; Teledyne Tekmar P…
Key words
temp, temppurge, purgebake, bakedesorb, desorbrinse, rinseacetate, acetatesweep, sweeptert, tertprecision, precisiontime, timeether, etherdemonstration, demonstrationcondensate, condensatevariable, variablemdl