Reducing Cycle Time for Analysis of 1,4-Dioxane using an Atomx Automated Sample Prep System
Applications | 2011 | Tekmar TeledyneInstrumentation
GC/MSD, Purge and Trap, GC/SQ
IndustriesEnvironmental
ManufacturerAgilent Technologies, Tekmar Teledyne
Key wordstemp, bake, rinse, purge, sweep, desorb, time, condensate, atomx, methanol, flow, sample, prepurge, needle, volume, prep, sparge, teledyne, rinses, dry, tekmar, glass, drain, vessel, water, soil, automated, heater, variable, parameters, ready, off, start, presweep, valve, runtime, preheat, value, mount, prime, standby, equilibrate, system, utilize, conjunction, axis, fill, number, msd, automation
Similar PDF
Requirements of an Automated Sample Delivery System in Today’s Realm of Ever Increasing Sensitivity Demands Utilizing the Atomx Concentrator/Multimatrix Autosampler
2009|Agilent Technologies|Applications
Requirements of an AutomatedSample Delivery System in Today’sRealm of Ever Increasing SensitivityDemands Utilizing the AtomxConcentrator/MultimatrixAutosampler.Application NoteBy: Anne JurekAbstractAs today’s instrumentation and experimental techniques improve on sensitivity and efficiency, we must also provide betterways to decrease carryover and ensure the instrumentation...
Key words
temp, tempbake, bakerinse, rinsepurge, purgedesorb, desorbcondensate, condensatesweep, sweepsparge, spargeneedle, needlevessel, vesselflow, flowtime, timeprepurge, prepurgemethanol, methanolvaried
Methanol Extraction of high level soil samples by USEPA Method 8260C
2011|Agilent Technologies|Applications
Methanol Extraction of highlevel soil samples by USEPAMethod 8260CAbstractIn order to determine the concentration of Volatile Organic Compounds (VOCs) in soil and waste samplesthe USEPA developed Method 8260C in conjunction with preparative Method 5035. USEPA Method 5035describes the process for...
Key words
temp, tempbake, bakerinse, rinsepurge, purgesweep, sweepmethanol, methanoldesorb, desorbcondensate, condensatetime, timeflow, flowprepurge, prepurgeneedle, needlevolume, volumesparge, spargetert
Validation of Volatile Organic Compound by USEPA Method 8260C
2011|Agilent Technologies|Applications
Validation of Volatile OrganicCompound by USEPAMethod 8260CApplication NoteAbstractIn order to determine the concentration of volatile organic compounds (VOCs) in water and soil matrices123the USEPA developed Method 8260C in conjunction with preparative Methods 5030 and 5035 . Waterand soil sample analysis...
Key words
temp, tempbake, bakedesorbs, desorbspurge, purgeusepa, useparinse, rinsecondensate, condensatesweep, sweepvolatile, volatiletime, timevalidation, validationcompound, compoundflow, flowprepurge, prepurgeneedle
Validation of Wisconsin Gasoline Range Organics
2011|Agilent Technologies|Applications
Validation of WisconsinGasoline Range OrganicsApplication NoteBy: Tyler TrentAbstractThe Wisconsin DNR Modified Gasoline RangeOrganics (Wisconsin GRO) Method is used todetermine gasoline and gasoline components inwater and soil. The water samples are analyzedby purge and trap, while the soil samplesundergo an additional...
Key words
temp, tempbake, bakerinse, rinsepurge, purgesweep, sweepwisconsin, wisconsinmethanol, methanoldesorb, desorbcondensate, condensateatomx, atomxtime, timegro, groflow, flowgasoline, gasolineprepurge