GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Analysis of 1,4-dioxane in Water by Purge and Trap and Triple Quadrupole GC/MS

Applications | 2021 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, Purge and Trap, GC/QQQ
Industries
Environmental
Manufacturer
Agilent Technologies, Tekmar Teledyne
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Food Testing & Environmental Analysis Application Compendium Table of Contents This application compendium contains a collection of environmental and food testing application notes demonstrating the low detection levels and sensitivity of the Agilent Triple Quadrupole GC/MS systems for the quantitation…
Key words
chlorohydrin, chlorohydrinethylene, ethylenesmoke, smokecresol, cresolcalibration, calibrationacquisition, acquisitionscan, scanguaiacol, guaiacoltime, timefull, fullsesame, sesamecompounds, compoundspurge, purgeagilent, agilentbenzo
Analysis of VOCs in soil using automated methanol extraction
2020|Thermo Fisher Scientific|Applications
TECHNICAL NOTE 73843 Analysis of VOCs in soil using automated methanol extraction Authors: Adam Ladak1, Terry Jeffers1, Dwain Cardona1, David Lee2, and Amy Nutter3 Thermo Fisher Scientific, USA Thermo Fisher Scientific, Runcorn, UK 3 Teledyne Tekmar, Mason, OH, USA 1…
Key words
bake, bakepurge, purgerinse, rinsemethanol, methanolsoil, soilatomx, atomxdesorb, desorbtemperature, temperaturecarryover, carryoverxyz, xyzsweep, sweepvariable, variableavrf, avrftime, timethermo
Application Note Environmental US EPA Method 524.3 – Atomx XYZ and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 524.3 was used to determine the concentration of volatile organic compounds (VOCs) in drinking…
Key words
temp, tempbake, bakepurge, purgerinse, rinsesweep, sweeptert, tertether, etherdesorb, desorbmethanol, methanoltime, timexyz, xyzatomx, atomxwater, waterteledyne, teledynetekmar
Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Author Amy Nutter Applications Chemist, Teledyne Tekmar Abstract US EPA Method 8260 in conjunction with Methods 5030 and 5035 was used to…
Key words
temp, temppurge, purgebake, bakedesorb, desorbrinse, rinsesweep, sweepmcs, mcsatomx, atomxtime, timevariable, variablexyz, xyzwater, waterneedle, needleflow, flowmethanol
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike